Background Partial thrombosis of the false lumen has been reported as a significant predictor of mortality during follow-up in patients with acute type B aortic dissection. The purpose of this study ...was to investigate the correlation of false lumen thrombosis and aortic expansion during follow-up in patients with acute type B aortic dissection. Methods All medically treated patients with acute type B aortic dissection observed in 4 cardiovascular referral centers between 1998 and 2011, with admission and follow-up computed tomography or magnetic resonance imaging scans, were included. Aortic diameters of the dissected aortas were measured at 4 levels on the baseline and follow-up scans, and annual growth rates were calculated. Univariate and multivariate regression analyses were used to investigate the effect of false lumen thrombosis on aortic growth rate. Results A total of 84 patients were included, of whom 40 (47.6%) had a partially thrombosed false lumen, 7 (8.3%) had a completely thrombosed false lumen, and 37 (44.0%) had a patent false lumen. A total of 273 of the 336 (81.3%) evaluated aortic levels were dissected segments. Overall, the mean aortic diameter increased significantly at all evaluated levels ( P < .001). Univariate analysis showed that annual aortic growth rates were significantly higher in those segments having a false lumen with partial thrombosis (mean, 4.25 ± 10.2) when compared with the patent group (mean, 2.10 ± 5.56; P = .035). In multivariate analysis, partial lumen thrombosis was an independent predictor of higher aortic growth (adjusted mean difference, 2.05 mm/year; 95% confidence interval, 0.10-4.01; P = .040). Conclusions In patients with acute type B aortic dissection, aortic segments with a partially thrombosed false lumen have a significantly higher annual aortic growth rate when compared with those presenting with patent or complete thrombosis of the false lumen. Therefore, patients with partial thrombosis require more intensive follow-up and may benefit from prophylactic intervention.
Background Conservative management of acute type B aortic dissection (ABAD) is often associated with aortic dilatation during follow-up increasing the risk of aortic rupture. The goal of this study ...was to investigate whether morphologic characteristics of the dissection can predict aortic growth. Methods All conservatively managed ABAD patients from four referral centers were included (2000 to 2010). Aortic diameters were measured at five levels at baseline and at the last follow-up computed tomography angiography, and annual aortic growth rates were calculated for all segments. Linear regression was used to study the influence of aortic morphologic characteristics for aortic dilatation. Results Included were 62 patients (41 men) with a mean age of 60.3 ± 10.7 years. Among the 310 analyzed aortic segments, 248 (80.0%) were dissected, of which 211 (85.1%) showed aortic growth. Overall, the mean diameter increased from 36.1 ± 9.4 to 40.2 ± 11.1 mm ( P < .01), which corresponds with a mean aortic growth rate of 3.1 ± 6.3 mm/y. Multivariate linear regression analysis showed that male sex (95% confidence interval CI, 0.60-4.04; P = .005) and a saccular false lumen (95% CI, 2.07-7.81: P = .001) were associated with a significantly increased aortic growth rate. Increasing age (95% CI, −0.23 to −0.04; P = .005), increased number of entry tears (95% CI, −2.40 to −0.43; P = .005), false lumen located on the aortic outer curvature (95% CI, −4.30 to −0.38; P = .019), and a circular configuration of the true lumen (95% CI, −5.35 to −0.32; P = .027) were associated with a decreased aortic growth rate. Conclusions Multiple morphologic characteristics appear to predict aortic dilatation in ABAD patients treated medically. Early assessment of these morphologic signs may be useful in the selection of ABAD patients who might benefit from closer radiologic surveillance or prophylactic intervention.
Abstract Objective Endovascular aneurysm repair (EVAR) has progressively expanded to treat more challenging anatomies. Although EVAR in patients with wide infrarenal necks has been reported with ...acceptable results, there is still controversy regarding the longer-term outcomes. Our aim is to determine the impact of infrarenal neck diameter on midterm outcome following EVAR with a single endograft with suprarenal fixation. Methods A retrospective case-control study was designed using data from a prospective multicenter database. Patients who electively underwent standard EVAR with an Endurant stent graft (Medtronic Ave, Santa Rosa, Calif) for a degenerative abdominal aortic aneurysm from January 2008 to December 2012 in three high-volume centers in The Netherlands were included. All measurements were obtained using dedicated reconstruction software and center-lumen line reconstruction. Patients with an infrarenal neck diameter of ≥30 mm were compared with patients with a neck diameter of <30 mm. The primary end point was freedom from neck-related adverse events (a composite of type Ia endoleak, neck-related secondary intervention, and endograft migration). Secondary end points were primary clinical success, type Ia endoleak, neck-related reinterventions, endoleaks, and aneurysm-related secondary interventions. Results Four-hundred twenty-seven patients were included. Seventy-four patients (17.3%) with a neck diameter of ≥30 mm were compared with a control group of 353 patients. There were no significant differences at baseline between groups including demographics, comorbidities, baseline aneurysm diameter, infrarenal neck length, suprarenal angulation, or infrarenal neck angulation. Median stent graft oversizing was 12.5% (7.9-16.1) and 16.6% (12.0-23.1) in the ≥30-mm neck-diameter and control groups, respectively ( P < .001). Median follow-up was 3.1 years (1.2-4.7) and 4.1 years (2.7-5.6) for the large neck and control groups, respectively ( P < .001). Type Ia endoleaks occurred in 17 patients (4.0%) and were significantly more frequent in patients with ≥30-mm neck diameter (9.5% vs 2.8%; P = .005). Neck-related secondary interventions were performed in 20 patients (4.7%) and were also more common among patients with neck diameters of ≥30 mm (9.5% vs 3.7%; P = .04). The 4-year freedom from neck-related adverse events were 75% and 95% for the large neck and control groups, respectively ( P < .001). On multivariable regression analysis, infrarenal neck diameter of ≥30 mm was an independent risk factor for neck-related adverse events (odds ratio OR, 3.8; 95% confidence interval CI, 1.6-9.1), type Ia endoleak (OR, 2.7; 95% CI, 1.0-8.3), and neck-related secondary interventions (OR, 3.2, 95% CI, 1.1-9.2). Conclusions EVAR in patients with large diameter necks is associated with an increased risk of neck-related adverse events in midterm follow-up. This may influence the clinical decision regarding choice of repair and toward a more intensive surveillance following EVAR in these patients in the long term.
Objective Intensive image surveillance after endovascular aneurysm repair is generally recommended due to continued risk of complications. However, patients at lower risk may not benefit from this ...strategy. We evaluated the predictive value of the first postoperative computed tomography angiography (CTA) characteristics for aneurysm-related adverse events as a means of patient selection for risk-adapted surveillance. Methods All patients treated with the Low-Permeability Excluder Endoprosthesis (W. L. Gore & Assoc, Flagstaff, Ariz) at a tertiary institution from 2004 to 2011 were included. First postoperative CTAs were analyzed for the presence of endoleaks, endograft kinking, distance from the lowermost renal artery to the start of the endograft, and for proximal and distal sealing length using center lumen line reconstructions. The primary end point was freedom from aneurysm-related adverse events. Multivariable Cox regression was used to test postoperative CTA characteristics as independent risk factors, which were subsequently used as selection criteria for low-risk and high-risk groups. Estimates for freedom from adverse events were obtained using Kaplan-Meier survival curves. Results Included were 131 patients. The median follow-up was 4.1 years (interquartile range, 2.1-6.1). During this period, 30 patients (23%) sustained aneurysm-related adverse events. Seal length <10 mm and presence of endoleak were significant risk factors for this end point. Patients were subsequently categorized as low-risk (proximal and distal seal length ≥10 mm and no endoleak, n = 62) or high-risk (seal length <10 mm or presence of endoleak, or both; n = 69). During follow-up, four low-risk patients (3%) and 26 high-risk patients (19%) sustained events ( P < .001). Four secondary interventions were required in three low-risk patients, and 31 secondary interventions in 23 high-risk patients. Sac growth was observed in two low-risk patients and in 15 high-risk patients. The 5-year estimates for freedom from aneurysm-related adverse events were 98% for the low-risk group and 52% for the high-risk group. For each diagnosis, 81.7 image examinations were necessary in the low-risk group and 8.2 in the high-risk group. Conclusions Our results suggest that the first postoperative CTA provides important information for risk stratification after endovascular aneurysm repair when the Excluder endoprosthesis is used. In patients with adequate seal and no endoleaks, the risk of aneurysm-related adverse events was significantly reduced, resulting in a large number of unnecessary image examinations. Adjusting the imaging protocol beyond 30 days and up to 5 years, based on individual patients' risk, may result in a more efficient and rational postoperative surveillance.
Background Aortic growth rate in acute type B aortic dissection (ABAD) is a significant predictor for aortic complications and death. To improve the overall outcome, radiologic predictors might ...stratify patients who benefit from successful medical management vs those who require intervention. This study investigated whether the number of identifiable entry tears in ABAD patients is associated with aortic growth. Methods ABAD patients with uncomplicated clinical conditions and therefore treated with medical therapy were evaluated. Those with a computed tomography angiography (CTA) obtained at clinical presentation and a subsequent CTA obtained at least 90 days after medical treatment were included (2005 to 2010). The CTAs were investigated for the number of entry tears between the true and false lumen. Diameters of the dissected aortas were measured at five levels on the baseline and on the last available follow-up CTA, and annual aortic growth rates were calculated. The number of entry tears in these patients and the location in the aorta were compared with the aortic growth rate. Results Included were 60 patients who presented with 243 dissected segments. Mean growth rates during follow-up (median, 23.2; range, 3 to 132 months) were significantly higher in patients with 1 entry tear (5.6 ± 8.9 mm) than in those with 2 (2.1 ± 1.7 mm; p = 0.001) and 3 entry tears (mean 2.2 ± 4.1; p = 0.010). The distance of the primary entry tear from the left subclavian artery did not have an effect on the aortic growth rate (median, 38; interquartile range, 24 to 137 mm; p = 0.434). Conclusions The number of entry tears in ABAD patients detected on the first CTA after clinical presentation is a significant predictor for aortic growth. Patients with 1 entry tear at presentation show a higher growth rate than other patients and might benefit from more strict surveillance or early prophylactic intervention.
Objective In this study, we analyzed the procedural success and early outcome of endovascular treatment of a multicenter cohort of patients with common iliac artery (CIA) aneurysms treated with the ...new GORE EXCLUDER (W. L. Gore & Associates, Flagstaff, Ariz) iliac branch endoprosthesis (IBE). Methods A retrospective cohort analysis was performed in 13 sites in The Netherlands. Anatomic, demographic, procedural, and follow-up data were assessed from hospital records. Results From November 2013 to December 2014, 51 CIA aneurysms were treated with an IBE in 46 patients. The median diameter of the treated aneurysm was 40.5 (range, 25.0-90.0) mm. The mean procedural time was 198 ± 56 minutes. All but one implantation were successful; two type Ib endoleaks were noticed, resulting in a procedural success rate of 93.5%. The two type Ib endoleaks spontaneously disappeared at 30 days. There was no 30-day mortality. Ipsilateral buttock claudication was present in only two cases at 30 days and disappeared during follow-up. The incidence of reported erectile dysfunction was low and severe ischemic complications were absent. After a mean follow-up of 6 months, data on 17 treated aneurysms were available. Two showed a stable diameter, whereas 15 showed a mean decrease of 3.9 ± 2.2 mm ( P < .001). Reinterventions were performed in two patients (7.1%). The 6-month primary patency of the internal component of the IBE device was 94%. Conclusions The use of the GORE EXCLUDER IBE device for CIA aneurysms is related to high procedural success, high patency rates, and low reintervention rates at short-term follow-up. Prospective data with longer follow-up are awaited to establish the role of the device in the treatment algorithm of CIA aneurysms.
Introduction Ruptured descending thoracic aortic aneurysm (rDTAA) is associated with high mortality rates. Data supporting endovascular thoracic aortic aneurysm repair (TEVAR) to reduce mortality ...compared with open repair are limited to small series. We investigated published reports for contemporary outcomes of open and endovascular repair of rDTAA. Methods We systematically reviewed all studies describing the outcomes of rDTAA treated with open repair or TEVAR since 1995 using MEDLINE, Cochrane Library CENTRAL, and Excerpta Medica Database (EMBASE) databases. Case reports or studies published before 1995 were excluded. All articles were critically appraised for relevance, validity, and availability of data regarding treatment outcomes. All data were systematically pooled, and meta-analyses were performed to investigate 30-day mortality, myocardial infarction, stroke, and paraplegia rates after both types of repair. Results Original data of 224 patients (70% male) with rDTAA were identified: 143 (64%) were treated with TEVAR and 81 (36%) with open repair. Mean age was 70 ± 5.6 years. The 30-day mortality was 19% for patients treated with TEVAR for rDTAA compared 33% for patients treated with open repair, which was significant (odds ratio OR, 2.15, P = .016). The 30-day occurrence rates of myocardial infarction (11.1% vs 3.5%; OR, 3.70, P < .05), stroke (10.2% vs 4.1%; OR, 2.67; P = .117), and paraplegia (5.5% vs 3.1%; OR, 1.83; P = .405) were increased after open repair vs TEVAR, but this failed to reach statistical significance for stroke and paraplegia. Five additional patients in the TEVAR group died of aneurysm-related causes after 30 days, during a median follow-up of 17 ± 10 months. Follow-up data after open repair were insufficient. The estimated aneurysm-related survival at 3 years after TEVAR was 70.6%. Conclusion Endovascular repair of rDTAA is associated with a significantly lower 30-day mortality rate compared with open surgical repair. TEVAR was associated with a considerable number of aneurysm-related deaths during follow-up.
Objective Evidence regarding the influence of cardiovascular risk factors, comorbidities, and patient characteristics on the growth of small abdominal aortic aneurysms (AAA) is limited. We assessed, ...in an observational cohort study, rupture rates, risks of mortality, and the effects of cardiovascular risk factors and patient demographics on growth rates of small AAAs. Methods Between September 1996 and January 2005, 5057 patients with manifest arterial vascular disease or cardiovascular risk factors were included in the Second Manifestation of ARTerial disease (SMART) study. Measurements of the abdominal aortic diameter were performed in all patients. All patients with an initial AAA diameter between 30 and 55 mm were selected for this study. All AAA measurements during follow-up until August 2007 were collected. Multivariate regression analysis was performed to calculate the effects of demographic patient characteristics, initial AAA diameter, and cardiovascular risk factors on AAA growth. Results Included were 230 patients, with a mean age of 66 years and 90% were male. Seven AAA ruptures (six fatal) occurred in 755 patient years of follow-up (rupture rate 0.9% per patient-year). In 147 patients, AAA measurements were performed for a period of more than 6 months. The median follow-up time was 3.3 years (mean 4.0, range 0.5 to 11.1 years, standard deviation (SD) 2.5). Mean AAA diameter was 38.8 mm (SD 6.8) and mean expansion rate 2.5 mm/y. Patients using lipid-lowering drugs had a 1.2 mm/y (95% confidence interval CI −2.34 to −0.060 mm/y) lower AAA growth rate compared to nonusers of these drugs. Initial AAA diameter was associated with a 0.09 mm/y (95% CI 0.01 to 0.18 mm/y) higher growth rate per millimetre increase of the diameter. No other factors, including blood lipid values, were independently associated with AAA growth. Conclusions Lipid-lowering drug treatment and initial AAA diameter appear to be independently associated with lower AAA growth rates. The risk of rupture of these small abdominal aortic aneurysms was low, which pleads for watchful waiting.
Background Ruptured descending thoracic aortic aneurysm (rDTAA) is a cardiovascular catastrophe, associated with high morbidity and mortality, which can be managed either by open surgery or thoracic ...endovascular aortic repair (TEVAR). The purpose of this study is to retrospectively compare the mortality, stroke, and paraplegia rates after open surgery and TEVAR for the management of rDTAA. Methods Patients with rDTAA treated with TEVAR or open surgery between 1995 and 2010 at seven institutions were identified and included for analysis. The outcomes between both treatment groups were compared; the primary end point of the study was a composite end point of death, permanent paraplegia, and/or stroke within 30 days after the intervention. Multivariate logistic regression analysis was used to identify risk factors for the primary end point. Results A total of 161 patients with rDTAA were included, of which 92 were treated with TEVAR and 69 with open surgery. The composite outcome of death, stroke, or permanent paraplegia occurred in 36.2% of the open repair group, compared with 21.7% of the TEVAR group (odds ratio OR, 0.49; 95% confidence interval CI, .24-.97; P = .044). The 30-day mortality was 24.6% after open surgery compared with 17.4% after TEVAR (OR, 0.64; 95% CI, .30-1.39; P = .260). Risk factors for the composite end point of death, permanent paraplegia, and/or stroke in multivariate analysis were increasing age (OR, 1.04; 95% CI, 1.01-1.08; P = .036) and hypovolemic shock (OR, 2.47; 95% CI, 1.09-5.60; P = .030), while TEVAR was associated with a significantly lower risk of the composite end point (OR, 0.44; 95% CI, .20-.95; P = .039). The aneurysm-related survival of patients treated with open repair was 64.3% at 4 years, compared with 75.2% for patients treated with TEVAR ( P = .191). Conclusions Endovascular repair of rDTAA is associated with a lower risk of a composite of death, stroke, and paraplegia, compared with traditional open surgery. In rDTAA patients, endovascular management appears the preferred treatment when this method is feasible.
Previous data have indicated that carotid plaque ulceration is a strong predictor of cerebrovascular events. Standard ultrasound and color Doppler ultrasound (CDUS) scans have poor diagnostic ...accuracy for the detection of carotid plaque ulceration. The aim of the present prospective study was to assess the value of contrast-enhanced ultrasound (CEUS) scans for the detection of carotid plaque ulceration. The Institutional Ethics Committee approved the study protocol, and all patients provided informed consent. The patients had symptomatic stenosis of the internal carotid artery and underwent carotid computed tomographic angiography as part of their clinical evaluation. All patients underwent a CDUS examination in conjunction with CEUS. Carotid plaque ulceration was defined as the presence of ≥1 disruptions in the plaque–lumen border ≥1 × 1 mm. Carotid computed tomographic angiography was used as reference technique. The study population consisted of 20 patients (mean age 64 ± 9 years, 80% men), and 39 carotid arteries were included in the present analysis. Computed tomographic angiography demonstrated that the plaque surface was smooth in 15 (38%), irregular in 7 (18%) and ulcerated in 17 (44%) carotid arteries. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CDUS for the detection of ulceration was 29%, 73%, 54%, 46%, and 57%, respectively. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CEUS for the detection of ulceration was 88%, 59%, 72%, 63%, and 87%, respectively. CEUS had superior sensitivity and diagnostic accuracy for the assessment of carotid plaque ulceration compared with CDUS. CEUS improved the intrareader and inter-reader variability for the assessment of carotid plaque ulceration compared with CDUS. In conclusion, CEUS could be an additional method for the detection of carotid plaque ulceration. The role of CDUS for the assessment of carotid plaque ulceration seems limited.