Summary Background Bioabsorbable vascular scaffolds were developed to overcome limitations of permanent bare-metal or drug-eluting coronary stents—ie, stent thrombosis (despite prolonged dual ...antiplatelet therapy), the life-long presence of a caged vessel segment that does not allow vasomotion or remodelling, and chronic vessel wall inflammation. We assessed the safety and performance of a new magnesium-based paclitaxel-eluting absorbable metal scaffold in symptomatic patients with de-novo coronary lesions. Methods We did a prospective, multicentre, first-in-man trial (BIOSOLVE-1) of the drug-eluting absorbable metal scaffold (DREAMS). 46 patients with 47 lesions were enrolled at five European centres. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation, at 6 and 12 months. Clinical follow-up was scheduled at 1, 6, 12, 24, and 36 months. Patients were consecutively assigned to angiographic and intravascular ultrasonographic follow-up at 6 months or 12 months. Optical coherence tomography was done in some patients. All patients were recommended to take dual antiplatelet therapy for at least 12 months. This trial is registered with ClinicalTrials.gov , number NCT01168830. Findings Overall device and procedural success was 100%. Two of 46 (4%) patients had target lesion failure at 6 months (both clinically driven target lesion revascularisations), which rose to three of 43 (7%) at 12 months (one periprocedural target vessel myocardial infarction occurred during angiography at the 12 month follow-up visit). We noted no cardiac death or scaffold thrombosis. Interpretation Our results show feasibility, a good safety profile, and promising clinical and angiographic performance results up to 12 months for DREAMS. Our promising clinical results show that absorbable metal scaffolds might be an alternative to polymeric absorbable scaffolds. Funding Biotronik.
Implantation of a device to narrow the coronary sinus and increase myocardial venous pressure was compared with a sham procedure in patients with refractory angina. The proportion of patients with ...improvement at 6 months was significantly greater with the device.
A growing number of patients with severe and diffuse obstructive coronary artery disease who are not candidates for revascularization have debilitating angina despite medical therapy.
1
–
3
The worldwide prevalence of refractory angina is increasing, and new therapeutic options are needed.
4
An endoluminal, balloon-expandable, stainless steel, hourglass-shaped device designed for percutaneous implantation in the coronary sinus (Reducer, Neovasc) creates a focal narrowing that leads to increased pressure in the coronary sinus, which may relieve angina (Figure 1). A nonrandomized first-in-human study involving 15 patients with refractory angina who were treated with the device showed significant improvement with respect to angina class. . . .
Abstract Background Mitral regurgitation (MR) is the most common valvular heart disease, and mitral valve surgery is the gold standard therapy for severe MR. Many patients with severe MR are not ...referred for surgery because of old age, comorbidities, or severe left ventricular dysfunction. Transcatheter mitral valve implantation may be a better therapeutic option for these high-risk patients with severe symptomatic MR. Objectives This study sought to describe the first-in-man series of transapical mitral valve implantation for mitral regurgitation with the TIARA device. Methods Extensive preclinical ex vivo and animal studies were conducted with the transapical mitral valve implantation of the Tiara system. The first 2 cases of human implantation were successfully performed in a 73-year-old man and a 61-year-old woman with severe functional MR. Both patients were in New York Heart Association class IV heart failure with depressed left ventricular ejection fraction, pulmonary hypertension, and additional comorbidities. Results The valve was implanted uneventfully in both patients. General anesthesia and transapical access were used. Patients were hemodynamically stable with no need for cardiopulmonary bypass. Immediately after implantation, systemic arterial pressure and stroke volume increased and pulmonary pressure decreased dramatically. There were no intraoperative complications, and both patients were extubated in the operating room. Post-procedural echocardiograms at 48 h, 1 month, and 2 months demonstrated excellent prosthetic valve function with a low transvalvular gradient and no left ventricular outflow tract obstruction. There was a trivial paravalvular leak in the first patient at 48 h, which was completely resolved at subsequent studies; no paravalvular leak occurred in the second patient. Conclusions Transapical transcatheter mitral valve implantation is technically feasible and can be performed safely. Early hemodynamic performance of the prosthesis was excellent. Transcatheter mitral valve implantation may become an important treatment option for patients with severe MR who are at high operative risk.
Increased Late Mortality After Sirolimus-Eluting Stents Versus Bare-Metal Stents in Diseased Saphenous Vein Grafts: Results From the Randomized DELAYED RRISC Trial Paul Vermeersch, Pierfrancesco ...Agostoni, Stefan Verheye, Paul Van den Heuvel, Carl Convens, Frank Van den Branden, Glenn Van Langenhove, the DELAYED RRISC (Death and Events at Long-term follow-up AnalYsis: Extended Duration of the Reduction of Restenosis In Saphenous vein grafts with Cypher stent) Investigators The long-term follow-up of the randomized RRISC (Reduction of Restenosis In Saphenous vein grafts with Cypher) trial, which compares sirolimus-eluting stents (SES) with bare-metal stents (BMS) in saphenous vein grafts, is presented. All 75 patients randomized to SES versus BMS underwent follow-up for up to 3 years. At a median time of 32 months, 29% of deaths occurred after SES versus 0% after BMS (p < 0.001). The rate of target vessel revascularization was not different (34% after SES vs. 38% after BMS, p = 0.74). In this secondary post-hoc analysis, BMS were associated with lower long-term mortality than SES for saphenous vein graft disease, without clear differences in terms of revascularization procedures.
Coronary sinus Reducer (CSR) implantation is currently recommended to relieve angina in patients with refractory symptoms despite optimal medical therapy and maximally achievable revascularization. ...The impact of diabetes mellitus on outcome after CSR implantation is at present unknown. We aimed to explore the impact of CSR in refractory angina patients with diabetes mellitus. Data from consecutive patients undergoing CSR implantation at four different centres between 2014 and 2018 were included. Patients were divided according to the presence or absence of diabetes mellitus. Primary objective of this analysis was to evaluate the clinical response to CSR implantation defined as an improvement of ≥ 1 classes of the Canadian Cardiovascular Society (CCS) Classification. A total of 219 patients were included, 116 (53%) of whom had diabetes mellitus. The median age of the population was 69 years and 167 patients (76%) were male. There were no significant differences between groups of patients with and without diabetes mellitus with respect to CCS class at baseline (
p
value = 0.32) and at follow-up (
p
= 0.75). Over a median follow-up of 393 224–1004 days, 84 (72%) of the patients with diabetes mellitus met the primary outcome, similarly to those without diabetes mellitus (
p
= 0.28). Fifty-three patients (24%) did not have an improvement in CCS class and no one experienced worsening of angina. CSR implantation was equally effective in improving angina symptoms among patients with refractory angina and diabetes mellitus compared to patients without diabetes mellitus.
The Tiara transcatheter mitral valve implantation system Verheye, Stefan; Cheung, Anson; Leon, Martin ...
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
11 Suppl W
Journal Article
Abstract Objectives This study sought to report the late multimodality imaging and clinical outcomes of the novel poly- l -lactic-acid–based DESolve novolimus-eluting bioresorbable coronary scaffold ...for the treatment of de novo coronary lesions. Background Bioresorbable scaffolds are an alternative to drug-eluting metallic stents and provide temporary vascular scaffolding, which potentially may allow vessel restoration and reduce the risk of future adverse events. Methods Overall, 126 patients were enrolled at 13 international sites between November 2011 and June 2012. The primary endpoint was in-scaffold late lumen loss at 6 months. Major adverse cardiac events, the main safety endpoint, were defined as the composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. All patients underwent angiography at 6 months. Serial intravascular ultrasound and optical coherence tomography were performed in a subset of patients. Results The scaffold device success rate was 97% (n = 122 of 126), and procedural success was 100% (n = 122 of 122). The major adverse cardiac event rate was 3.3% (n = 4 of 122) at 6 months and 7.4% (n = 9 of 122) at 24 months, including 1 probable stent thrombosis within the first month. At 6-month angiographic follow-up, in-scaffold late lumen loss was 0.20 ± 0.32 mm. Paired intravascular ultrasound analysis demonstrated a significant increase in vessel, lumen and scaffold dimensions between post-procedure and 6-month follow-up, and strut-level optical coherence tomography analysis showed full strut coverage in 99 ± 1.7%. Conclusions Our results showed favorable performance of the DESolve scaffold, effective inhibition of neointimal hyperplasia, and for the first time, early luminal and scaffold growth at 6 months with sustained efficacy and safety through 2 years. (Elixir Medical Clinical Evaluation of the DESolve Novolimus Eluting Bioresorbable Coronary Scaffold System—The DESolve Nx Trial; NCT02086045 )
Objectives This study sought to demonstrate the noninferiority of polymer-free amphilimus-eluting stents (Cre8, CID, Saluggia, Italy) versus permanent-polymer paclitaxel-eluting stents (Taxus ...Liberté, Boston Scientific, Natick, Massachusetts) in de novo percutaneous coronary intervention. Background Although the efficacy of the drug-eluting stent has been well established, the risk-benefit balance is still suboptimal, and the safety of polymers remains uncertain. Methods Patients undergoing percutaneous coronary intervention for de novo lesions were randomly assigned 1:1 to Cre8 or Taxus Liberté stents. Primary endpoint was 6-month angiographic in-stent late lumen loss (LLL) within a noninferiority scope. Six-month intravascular ultrasound was performed in 20% of the patients. All patients will be clinically followed up to 5 years. Results Out of 323 patients enrolled, 162 received Cre8 and 161 Taxus Liberté stents. In-stent LLL was significantly lower in Cre8 group (0.14 ± 0.36 mm vs. 0.34 ± 0.40 mm, p noninferiority <0.0001, p superiority <0.0001). Clinical endpoints (cardiac death, myocardial infarction, target lesion revascularization, and stent thrombosis) up to 12 months did not differ significantly between the groups. Conclusions The Cre8 stent in de novo lesions showed significantly lower in-stent LLL at 6 months than the Taxus Liberté stent did, with a trend toward better 12-month clinical safety and efficacy results. (International Randomized Comparison Between DES Limus Carbostent and Taxus Drug-Eluting Stents in the Treatment of De Novo Coronary Lesions NEXT; NCT01373502 )
Background: The DynamX Novolimus-Eluting Coronary Bioadaptor System (DynamX® Bioadaptor) has uncaging elements that disengage after the resorption of the polymer coating, aiming to restore vessel ...function in the treated segment and to avoid long-term adverse outcomes associated with the permanent caging of the coronary artery seen with conventional stenting. Methods: This prospective, multicenter, single-arm first-in-human study enrolled 50 patients in Belgium and Italy who were treated with the DynamX Bioadaptor. Eligible patients had de novo lesions in coronary arteries measuring between 2.5 and 3.5 mm in diameter and ≤24 mm in length. Clinical follow-up was performed up to 36 months. This analysis includes the intention-to-treat population and is based on data available. The preclinical studies include optical coherence tomography (OCT) analyses of 5 DynamX Bioadaptors implanted in 3 mini Yucatan pigs (at 3, 12 and 24 months), and assessment of smooth muscle cell gene expression profile in 8 pigs of which each was implanted with the DynamX Bioadaptor and the Xience drug-eluting stent. To assess the gene expression profile by quantitative real-time polymerase chain reaction, animals were sacrificed at 3, 6, 9 and 12 months. Results: Target lesion failure at 36 months was 8.7% (4/46), consisting of one clinically-driven target lesion revascularization and 3 cardiac deaths (all site-reported to be unrelated to the device or procedure). There were no additional target vessel revascularization and no definite or probable scaffold thrombosis. Preclinical data confirmed late lumen enlargement (from 7.02 ± 1.31 mm2 at baseline to 8.46 ± 1.31 mm2 at 24 months) and identified an increased expression of contractile genes around 9 months compared to a conventional drug-eluting stent. Conclusions: The DynamX Bioadaptor demonstrated very good 36-month clinical outcomes, highlighted by the absence of target-vessel myocardial infarction and definite or probable device thrombosis, and only one target lesion revascularization up to 36 months. These data are supported by preclinical studies that showed late lumen enlargement by OCT and an increased expression of contractile genes around 9 months compared to conventional drug-eluting stents, indicating faster vessel healing. Larger clinical studies are necessary to compare outcomes against contemporary drug-eluting stents. Clinical Trial Registration: https://clinicaltrials.gov/: NCT03429894.