Carbapenem-resistant
(CRE) are major health care-associated pathogens and responsible for hospital outbreaks worldwide. To prevent a further increase in CRE infections and to improve infection ...prevention strategies, it is important to summarize the current knowledge about CRE infection prevention in hospital settings. This systematic review aimed to identify risk factors for CRE acquisition among hospitalized patients. In addition, we summarized the environmental sources/reservoirs and the most successful infection prevention strategies related to CRE. A total of 3,983 potentially relevant articles were identified and screened. Finally, we included 162 studies in the systematic review, of which 69 studies regarding risk factors for CRE acquisition were included in the random-effects meta-analysis studies. The meta-analyses regarding risk factors for CRE acquisition showed that the use of medical devices generated the highest pooled estimate (odds ratio OR = 5.09; 95% confidence interval CI = 3.38 to 7.67), followed by carbapenem use (OR = 4.71; 95% CI = 3.54 to 6.26). To control hospital outbreaks, bundled interventions, including the use of barrier/contact precautions for patients colonized or infected with CRE, are needed. In addition, it is necessary to optimize the therapeutic approach, which is an important message to infectious disease specialists, who need to be actively involved in a timely manner in the treatment of patients with known CRE infections or suspected carriers of CRE.
Healthcare-related infections caused by extended-spectrum beta-lactamase (ESBL)-producing Klebsiella spp. are of major concern. To control transmission, deep understanding of the transmission ...mechanisms is needed. This systematic review aimed to identify risk factors and sources, clonal relatedness using molecular techniques, and the most effective control strategies for ESBL-producing Klebsiella spp. A systematic search of PubMed, Embase, and Outbreak Database was performed. We identified 2771 articles from November 25th, 1960 until April 7th, 2014 of which 148 were included in the systematic review and 23 in a random-effects meta-analysis study. The random-effects meta-analyses showed that underlying disease or condition (odds ratio OR = 6.25; 95% confidence interval CI = 2.85 to 13.66) generated the highest pooled estimate. ESBL-producing Klebsiella spp. were spread through person-to-person contact and via sources in the environment; we identified both monoclonal and polyclonal presence. Multi-faceted interventions are needed to prevent transmission of ESBL-producing Klebsiella spp.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
In healthcare environments, sinks are being increasingly recognized as reservoirs for multidrug-resistant Gram-negative bacteria. In our hospital, carbapenemase-producing, Verona Integron-encoded ...Metallo-beta-lactamase (VIM)-positive Pseudomonas aeruginosa (VIM-PA) was detected at low endemicity in patients, and environmental culturing revealed that sink drains were primary reservoirs. Therefore, an intervention was initiated in several wards to install sink drain plugs as physical barriers against splashing to prevent transmission of VIM-PA from drain reservoirs to the surrounding sink environment.
To assess the efficacy of the intervention on limiting spread of VIM-PA.
Swabs were taken from inner sink environments (i.e. drains), and outer sink environments (i.e. wash basins, faucet aerators, and countertops) twice before and three times after the intervention. Siphon water and drain wells were also sampled before and at the moment of the intervention, respectively. All samples were screened for VIM-PA, and isolates were typed with multiple-locus variable-number tandem repeat analysis (MLVA).
There was a significant reduction in VIM-PA positivity in both inner (P-value <0.001) and outer (P-value 0.001) sink environments after the intervention. However, VIM-PA recolonization was observed in the inner sink environments of patient rooms, and also in rooms exclusive to healthcare personnel, over time. Surfaces in the outer sink environment were rarely positive for VIM-PA after the intervention. MLVA revealed three genetic clusters, with one found in all wards and room types during the study period.
Drain plugs are a simple and effective infection prevention and control measure to contain spread of VIM-PA from drain reservoirs.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Contaminated duodenoscopes caused several hospital outbreaks. Despite efforts to reduce contamination rates, 15% of patient-ready duodenoscopes are still contaminated with gastrointestinal ...microorganisms. This study aimed to provide an overview of duodenoscope contamination over time, identify risk factors and study the effects of implemented interventions.
Duodenoscope culture sets between March 2015 and June 2022 at a Dutch tertiary care centre were analysed. Contamination was defined as (1) the presence of microorganisms of oral or gastrointestinal origin (MGO) or (2) any other microorganism with ≥20 colony-forming units/20 mL (AM20). A logistic mixed effects model was used to identify risk factors and assess the effect of interventions, such as using duodenoscopes with disposable caps, replacing automated endoscope reprocessors (AER) and conducting audits in the endoscopy department.
A total of 404 culture sets were analysed. The yearly contamination rate with MGO showed great variation, ranging from 14.3% to 47.5%. Contamination with AM20 increased up to 94.7% by 2022. For both MGO and AM20, the biopsy and suction channels were the most frequently contaminated duodenoscope components. The studied interventions, including audits, AER replacement and implementation of duodenoscopes with disposable caps, did not show a clear association with contamination rates.
Duodenoscope contamination remains a significant problem, with high contamination rates despite several interventions. Reprocessing the biopsy and suction channels is especially challenging. Changes in the design of reusable duodenoscopes, such as enabling sterilisation or easily replaceable channels, are necessary to facilitate effective duodenoscope reprocessing and to eliminate the risk of duodenoscope-associated infections.
A systematic review and meta-analyses were performed to identify the risk factors associated with carbapenem-resistant Pseudomonas aeruginosa and to identify sources and reservoirs for the pathogen. ...A systematic search of PubMed and Embase databases from 1 January 1987 until 27 January 2012 identified 1,662 articles, 53 of which were included in a systematic review and 38 in a random-effects meta-analysis study. The use of carbapenem, use of fluoroquinolones, use of vancomycin, use of other antibiotics, having medical devices, intensive care unit (ICU) admission, having underlying diseases, patient characteristics, and length of hospital stay were significant risk factors in multivariate analyses. The meta-analyses showed that carbapenem use (odds ratio OR = 7.09; 95% confidence interval CI = 5.43 to 9.25) and medical devices (OR = 5.11; 95% CI = 3.55 to 7.37) generated the highest pooled estimates. Cumulative meta-analyses showed that the pooled estimate of carbapenem use was stable and that the pooled estimate of the risk factor "having medical devices" increased with time. We conclude that our results highlight the importance of antibiotic stewardship and the thoughtful use of medical devices in helping prevent outbreaks of carbapenem-resistant P. aeruginosa.
Timely identification of patients who carry multidrug-resistant microorganisms (MDRO) is needed to prevent nosocomial spread to other patients and to the hospital environment. We aimed to compare the ...yield of a universal screening strategy upon admission to the currently installed universal risk assessment combined with risk-based screening upon admission.
This observational study was conducted within a prospective cohort study. From January 1, 2018, until September 1, 2019, patients admitted to our hospital were asked to participate. Nasal and perianal samples were taken upon admission and checked for the presence of MDRO. The results of the universal risk assessment and risk-based screening were collected retrospectively from electronic health records.
In total, 1017 patients with 1069 separate hospital admissions participated in the study. Universal screening identified 38 (3.6%) unknown MDRO carriers upon admission (37 individual patients), all carrying extended-spectrum beta-lactamase-producing Enterobacterales. For 946 of 1069 (88.5%) patients, both the universal risk assessment and universal screening were performed. For 19 (2.0%) admissions, ≥1 risk factor was identified. The universal risk assessment identified one (0.1%) unknown carrier, compared to 37 out of 946 carriers for the universal screening (P<0.001). Of the 37 carriers identified through the universal screening, 35 (94.6%) reported no risk factors.
Our results show that in our low endemic setting, a universal screening strategy identified significantly more MDRO carriers than the currently implemented universal risk-assessment. When implementing a universal risk-assessment, risk factors should be carefully selected to be able to identify ESBL-E carriers. While the universal screening identified more MDRO carriers, further research is needed to determine the cost-effectiveness of this strategy.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Contaminated duodenoscopes and linear echoendoscopes (DLEs) pose a risk for infectious outbreaks. To identify DLEs and reprocessing risk factors, we combined the data from the previously published ...nationwide cross-sectional PROCESS 1 study (Prevalence of contamination of complex endoscopes in the Netherlands) with the follow-up PROCESS 2 study.
We invited all 74 Dutch DLE centers to sample ≥2 duodenoscopes during PROCESS 1, and all duodenoscopes as well as linear echoendoscopes during PROCESS 2. The studies took place 1 year after another. Local staff sampled each DLE at ≤6 sites according to uniform methods explained by online videos. We used 2 contamination definitions: (1) any microorganism with ≥20 colony-forming units (CFU)/20 mL (AM20) and (2) presence of microorganisms with GI or oral origin, independent of CFU count (MGOs). We assessed the factors of age and usage by performing an analysis of pooled data of both PROCESS studies; additional factors including reprocessing characteristics were only recorded in PROCESS 2.
Ninety-seven percent of all Dutch centers (72 of 74; PROCESS 1, 66; PROCESS 2, 61) participated in one of the studies, sampling 309 duodenoscopes and 64 linear echoendoscopes. In total, 54 (17%) duodenoscopes and 8 (13%) linear echoendoscopes were contaminated according to the AM20 definition. MGOs were detected on 47 (15%) duodenoscopes and 9 (14%) linear echoendoscopes. Contamination was not age or usage dependent (all P values ≥.27) and was not shown to differ between the reprocessing characteristics (all P values ≥.01).
In these nationwide studies, we found that DLE contamination was independent of age and usage. These results suggest that old and heavily used DLEs, if maintained correctly, have a similar risk for contamination as new DLEs. The prevalence of MGO contamination of ∼15% was similarly high for duodenoscopes as for linear echoendoscopes, rendering patients undergoing ERCP and EUS at risk for transmission of microorganisms.