On the basis of the Next Accreditation System, trainee assessment should occur on a continuous basis with individualized feedback. We aimed to validate endoscopic ultrasound (EUS) and endoscopic ...retrograde cholangiopancreatography (ERCP) learning curves among advanced endoscopy trainees (AETs) by using a large national sample of training programs and to develop a centralized database that allows assessment of performance in relation to peers.
ASGE recognized training programs were invited to participate, and AETs were graded on ERCP and EUS exams by using a validated competency assessment tool that assesses technical and cognitive competence in a continuous fashion. Grading for each skill was done by using a 4-point scoring system, and a comprehensive data collection and reporting system was built to create learning curves by using cumulative sum analysis. Individual results and benchmarking to peers were shared with AETs and trainers quarterly.
Of the 62 programs invited, 20 programs and 22 AETs participated in this study. At the end of training, median number of EUS and ERCP performed/AET was 300 (range, 155-650) and 350 (125-500), respectively. Overall, 3786 exams were graded (EUS, 1137; ERCP-biliary, 2280; ERCP-pancreatic, 369). Learning curves for individual end points and overall technical/cognitive aspects in EUS and ERCP demonstrated substantial variability and were successfully shared with all programs. The majority of trainees achieved overall technical (EUS, 82%; ERCP, 60%) and cognitive (EUS, 76%; ERCP, 100%) competence at conclusion of training.
These results demonstrate the feasibility of establishing a centralized database to report individualized learning curves and confirm the substantial variability in time to achieve competence among AETs in EUS and ERCP. ClinicalTrials.gov: NCT02509416.
Background and Aims The exact cutoff value at which pancreatic cyst fluid carcinoembryonic antigen (CEA) level distinguishes pancreatic mucinous cystic neoplasms (MCNs) from pancreatic nonmucinous ...cystic neoplasms (NMCNs) is unclear. The aim of this multicenter retrospective study was to evaluate the diagnostic accuracy of cyst fluid CEA levels in differentiating between MCNs and NMCNs. Methods Consecutive patients who underwent EUS with FNA at 3 tertiary care centers were identified. Patients with histologic confirmation of cyst type based on surgical specimens served as the criterion standard for this analysis. Demographic characteristics, EUS morphology, FNA fluid, and cytology results were recorded. Multivariate logistic regression analysis to identify predictors of MCNs was performed. Receiver-operating characteristic (ROC) curves were generated for CEA levels. Results A total of 226 patients underwent surgery (mean age, 61 years, 96% white patients, 39% female patients) of whom 88% underwent Whipple’s procedure or distal pancreatectomy. Based on surgical histopathology, there were 150 MCNs and 76 NMCNs cases. The median CEA level was 165 ng/mL. The area under the ROC curve for CEA levels in differentiating between MCNs and NMCNs was 0.77 (95% confidence interval, 0.71–0.84, P < .01) with a cutoff of 105 ng/mL, demonstrating a sensitivity and specificity of 70% and 63%, respectively. The cutoff value of 192 ng/mL yielded a sensitivity of 61% and a specificity of 77% and would misdiagnose 39% of MCN cases. Conclusions Cyst fluid CEA levels have a clinically suboptimal accuracy level in differentiating MCNs from NMCNs. Future studies should focus on novel cyst fluid markers to improve risk stratification of pancreatic cystic neoplasms.
Background and Aims Endoscopic resection (ER) is an efficacious treatment for complex colon polyps (CCPs). Many patients are referred for surgical resection because of concerns over procedural ...safety, incomplete polyp resection, and adenoma recurrence after ER. Efficacy data for both resection strategies are widely available, but a paucity of data exist on the cost-effectiveness of each modality. The aim of this study was to perform an economic analysis comparing ER and laparoscopic resection (LR) strategies in patients with CCP. Methods A decision analysis tree was constructed using decision analysis software. The 2 strategies (ER vs LR) were evaluated in a hypothetical cohort of patients with CCPs. A hybrid Markov model with a 10-year time horizon was used. Patients entered the model after colonoscopic diagnosis at age 50. Under Strategy I, patients underwent ER followed by surveillance colonoscopy at 3 to 6 months and 12 months. Patients with failed ER and residual adenoma at 12 months were referred for LR. Under Strategy II, patients underwent LR as primary treatment. Patients with invasive cancer were excluded. Estimates regarding ER performance characteristics were obtained from a systematic review of published literature. The Centers for Medicare & Medicaid Services (2012-2013) and the 2012 Healthcare Cost and Utilization Project databases were used to determine the costs and loss of utility. We assumed that all procedures were performed with anesthesia support, and patients with adverse events in both strategies required inpatient hospitalization. Baseline estimates and costs were varied by using a sensitivity analysis through the ranges. Results LR was found to be more costly and yielded fewer quality-adjusted life-years (QALYs) compared with ER. The cost of ER of a CCP was $5570 per patient and yielded 9.640 QALYs. LR of a CCP cost $18,717 per patient and yielded fewer QALYs (9.577). For LR to be more cost-effective, the thresholds of 1-way sensitivity analyses were (1) technical success of ER for complete resection in <75.8% of cases, (2) adverse event rates for ER > 12%, and (3) LR cost of <$14,000. Conclusions Our data suggest that ER is a cost-effective strategy for removal of CCPs. The effectiveness is driven by high technical success and low adverse event rates associated with ER, in addition to the increased cost of LR.