Venous resection of the superior mesenteric or portal vein is increasingly performed in pancreatic cancer surgery, whereas results of studies on short- and long-term outcomes are contradictory. The ...aim of this study was to evaluate the impact of the type of venous resection in pancreatoduodenectomy for pancreatic cancer on postoperative morbidity and overall survival.
This nationwide retrospective cohort study included all patients who underwent pancreatoduodenectomy for pancreatic cancer in 18 centres (2013-2017).
A total of 1311 patients were included, of whom 17 per cent underwent wedge resection and 10 per cent segmental resection. Patients with segmental resection had higher rates of major morbidity (39 versus 20 versus 23 per cent, respectively; P < 0.001) and portal or superior mesenteric vein thrombosis (18 versus 5 versus 1 per cent, respectively; P < 0.001) and worse overall survival (median 12 versus 16 versus 20 months, respectively; P < 0.001), compared to patients with wedge resection and those without venous resection. Multivariable analysis showed patients with segmental resection, but not those who had wedge resection, had higher rates of major morbidity (odds ratio = 1.93, 95 per cent c.i. 1.20 to 3.11) and worse overall survival (hazard ratio = 1.40, 95 per cent c.i. 1.10 to 1.78), compared to patients without venous resection. Among patients who received neoadjuvant therapy, there was no difference in overall survival among patients with segmental and wedge resection and those without venous resection (median 32 versus 25 versus 33 months, respectively; P = 0.470), although there was a difference in major morbidity rates (52 versus 19 versus 21 per cent, respectively; P = 0.012).
In pancreatic surgery, the short- and long-term outcomes are worse in patients with venous segmental resection, compared to patients with wedge resection and those without venous resection.
Practice variation exists in venous resection during pancreatoduodenectomy, but little is known about the potential causes and consequences as large studies are lacking. This study explores the ...potential causes and consequences of practice variation in venous resection during pancreatoduodenectomy for pancreatic cancer in the Netherlands.
This nationwide retrospective cohort study included patients undergoing pancreatoduodenectomy for pancreatic cancer in 18 centers from 2013 through 2017.
Among 1,311 patients undergoing pancreatoduodenectomy, 351 (27%) had a venous resection, and the overall median annual center volume of venous resection was 4. No association was found between the center volume of pancreatoduodenectomy and the rate of venous resections, nor between patient and tumor characteristics and the rate of venous resections per center. Female sex, lower body mass index, neoadjuvant therapy, venous involvement, and stenosis on imaging were predictive for venous resection. Adjusted for these factors, 3 centers performed significantly more, and 3 centers performed significantly fewer venous resections than expected. In patients with venous resection, significantly less major morbidity (22% vs 38%) and longer overall survival (median 16 vs 12 months) were observed in centers with an above-median annual volume of venous resections (>4).
Patient and tumor characteristics did not explain significant practice variation between centers in the Netherlands in venous resection during pancreatoduodenectomy for pancreatic cancer. The clinical outcomes of venous resection might be related to the volume of the procedure.
To assess the value of measurements of superior mesenteric artery flow using Doppler ultrasound for detecting disease activity in patients with proven or suspected Crohn's disease.
Superior ...mesenteric artery flow was measured prospectively in 31 patients with known or suspected small-bowel disease. Sixteen patients were known to suffer from Crohn's disease and were suspected of having active disease. Fifteen patients had abdominal complaints without a specific diagnosis. Enteroclysis was used as the standard of reference to detect Crohn's disease, to define the location of small-bowel Crohn's disease, and to assess disease activity by demonstrating cobblestoning. Disease activity was further substantiated by clinical signs, laboratory values, and clinical follow-up.
Ten patients with active disease on enteroclysis made up group 1. Group 2 comprised nine patients known to have Crohn's disease but without active disease (inactive small-bowel disease). The remaining 12 patients made up group 3. In group 1, the flow volume values were significantly higher than those in group 2 and group 3: 738 +/- 411 (mean +/- SD) versus 364 +/- 101 and 300 +/- 91, respectively (p < 0.05).
Whereas the initial diagnosis of small-bowel involvement in Crohn's disease may rely on enteroclysis, Doppler measurements of superior mesenteric artery flow are useful to monitor the activity of Crohn's disease.
MR angiography of the head and neck region has been studied widely, but few studies have been performed concerning the efficacy of MR angiography for the identification of the specific vascular ...supply of the highly vascular head and neck paragangliomas. In this study, we compared three MR angiography techniques with respect to visualization of branch arteries in the neck and identification of tumor feeders in patients with paragangliomas.
Fourteen patients with 29 paragangliomas were examined at 1.5 T using 3D phase-contrast (PC), 2D time-of-flight (2D TOF), and multi-slab 3D TOF MR angiography. In the first part of the study, two radiologists independently evaluated the visibility of first-, second-, and third-order branch arteries in the neck. In the second part of the study, the number of feeding arteries for every paraganglioma was determined and compared with digital subtraction angiography (DSA), the standard of reference in this study.
Three-dimensional TOF angiography was superior to the other MR angiography techniques studied (P < .05) for depicting branch arteries of the external carotid artery in the neck, but only first- and second-order vessels were reliably shown. DSA showed a total of 78 feeding arteries in the group of patients with 29 paragangliomas, which was superior to what was revealed by all MR angiography techniques studied. More tumor feeders were identified with 3D TOF and 2D TOF angiography than with 3D PC MR angiography (P < .05), with a sensitivity/specificity of 61%/98%, 54%/95%, and 31%/95%, respectively. Sensitivity was lowest for carotid body tumors.
Compared with intra-arterial DSA, the 3D TOF MR angiography technique was superior to 3D PC and 2D TOF MR angiography for identifying the first- and second-order vessels in the neck. With 3D TOF angiography, more tumor feeders were identified than with the other MR angiography techniques studied. The sensitivity of MR angiography, however, is not high enough to reveal important vascularization. The sensitivity of MR angiography is too low to replace DSA, especially in the presence of carotid body tumors.
The tenderness and palatability of retail and food service beef steaks from across the United States (12 cities for retail, 5 cities for food service) were evaluated using Warner-Bratzler shear (WBS) ...and consumer sensory panels. Subprimal postfabrication storage or aging times at retail establishments averaged 20.5 d with a range of 1 to 358 d, whereas postfabrication times at the food service level revealed an average time of 28.1 d with a range of 9 to 67 d. Approximately 64% of retail steaks were labeled with a packer/processor or store brand. For retail, top blade had among the lowest (P < 0.05) WBS values, whereas steaks from the round had the greatest (P < 0.05) values. There were no differences (P > 0.05) in WBS values between moist-heat and dry-heat cookery methods for the top round and bottom round steaks or between enhanced (contained salt or phosphate solution) or nonenhanced steaks. Food service top loin and rib eye steaks had the lowest (P < 0.05) WBS values compared with top sirloin steaks. Retail top blade steaks and food service top loin steaks received among the greatest (P < 0.05) consumer sensory panel ratings compared with the other steaks evaluated. Prime food service rib eye steaks received the greatest ratings (P < 0.05) for overall like, like tenderness, tenderness level, like juiciness, and juiciness level, whereas ungraded rib eye steaks received the lowest ratings (P < 0.05) for like tenderness and tenderness level. The WBS values for food service steaks were greater (P < 0.05) for the Select and ungraded groups compared with the Prime, Top Choice, and Low Choice groups. The WBS values and sensory ratings were comparable to the last survey, signifying that no recent or substantive changes in tenderness have occurred.
In this study, a T
1-weighted three-dimensional (3D) spoiled gradient-echo scanning protocol was developed to image the complete arterial system of the pelvis and both legs along their entire length ...in patients with peripheral arterial disease. Three adjacent stations were to be acquired consecutively, with some overlap, to image the entire area of interest; per station one gadolinium (Gd) contrast bolus would be administered. In an in vitro phantom study, the scanning protocol was optimized. The optimal flip angle was found to be 50°. Also, the optimal scan delay was chosen to be equal to the arrival time of the contrast bolus, thereby minimizing artifacts. Three contrast bolus injections showed sufficient enhancement of the vessels after image subtraction. Finally, stenosis quantification by manual caliper was performed by five observers in the magnetic resonance angiography (MRA) images and correlated with the percent diameter reduction determined by quantitative angiography from corresponding X-ray images. The MRA measurements were reproducible, and intra- and interobserver variabilities were statistically non-significant (
p = 0.54 and
p = 0.12, respectively). Stenosis quantification performed by four observers showed a good correlation with the X-ray-derived values (r
P > 0.90,
p < 0.02); the results from one observer were not significantly correlated. Five patients with proven peripheral disease were investigated with this new MRA scanning protocol, using standard hardware and software. The images were of good quality, which allowed adequate clinical evaluation; the original diagnoses obtained from X-ray examinations, were confirmed with MRA. In conclusion, peripheral arterial disease can be evaluated adequately with this magnetic resonance scanning protocol.
Background/Aims: The aim was to study the reproducibility of magnetic resonance velocity mapping, when measuring portal vein and superior mesenteric artery blood flow, under fasting and post-prandial ...conditions. Magnetic resonance flow measurements for the portal vein were compared with echo-Doppler measurements in the right portal vein.
Methods: Eight healthy volunteers were studied on two occasions, separated by 1 week. Blood flow in the portal vein and superior mesenteric artery was measured repeatedly under basal fasting conditions. On one occasion measurements were also made after a meal. Every magnetic resonance measurement was followed by an echo-Doppler measurement in the right portal vein. Correlations between flow values were calculated using Pearson's
r. Variability components were assessed using ANOVA.
Results: Intra-individual variability was approximately 7% for portal vein flow measurements using magnetic resonance velocity mapping. This variability did not increase after 1 h, 1 week and after a meal. Values of flow measured in the portal vein and superior mesenteric artery using magnetic resonance velocity mapping correlated well (
r=0.80,
p<0.001). Fasting portal flow as measured with magnetic resonance velocity mapping was 1.2 l/min (range 0.96-1.6 l/min). Variability in echo-Doppler measurements was comparable to the variability of magnetic resonance velocity mapping, and flow measurements obtained with the two techniques correlated well (
r=0.74;
p<0.001).
Conclusions: Magnetic resonance velocity mapping accurately measures blood flow in the portal vein with low variability and should be preferred when absolute flow values are necessary. Echo-Doppler measurement of the right portal vein has a low variability and can be used to study changes in flow.
To compare respiratory-triggered inversion-recovery (IR) gradient- and spin-echo (GRASE) magnetic resonance (MR) imaging with respiratory-triggered T2-weighted fast spin-echo (SE) imaging in the ...diagnosis of liver metastases.
In this prospective study, two radiologists independently identified focal hepatic lesions on respiratory-triggered IR GRASE and respiratory-triggered fast SE MR images in 28 consecutive patients with 186 (135 malignant and 51 benign) proved lesions. A combination of findings at surgery, intraoperative ultrasonography (US), and histologic examination served as the standard of reference. Contrast-to-noise ratios (CNRs) were obtained from 86 lesions larger than 10 mm.
The sensitivity in the detection of liver metastases was, independent of lesion size and observer, higher for IR GRASE imaging (55%) than for fast SE imaging (44%-50%) (observer 1, P = .014; observer 2, P = .21). Confidence levels with IR GRASE imaging were higher, but not significantly so, than those with fast SE imaging (P < .098). Both observers characterized liver lesions better with IR GRASE than with fast SE imaging (observer 1, P = .04; observer 2, P = .48). The metastasis-liver CNR was significantly higher (P = .012) with IR GRASE imaging.
The respiratory-triggered IR GRASE sequence is a fast alternative to the respiratory-triggered fast SE sequence in the evaluation of suspected liver metastases.
Waveform variations in blood flow measurements through stenotic renal arteries have been reported already with echo Doppler studies. We studied these variations with MRI in 14 patients (mean age, 60 ...years) with suspected renal arterial stenosis (24 patent arteries, four occluded). Flow measurements were successful in 15 arteries and unsuccessful in nine, due to practical limitations. Seven healthy younger volunteers (mean age, 28 years) and five healthy older volunteers (mean age, 58 years) were recruited for comparison purposes. In patients, the severity of stenoses was also assessed by digital subtraction angiography and intraarterially measured transstenotic pressure drops. We found flow patterns to be statistically significantly (P < 0.01) age‐related. Younger healthy subjects showed shorter wave duration, higher diastolic flow, and total blood flow per minute. Also, with increasing stenosis severity, the systolic wave became more damped and the systolic wave duration became statistically significantly (P> = .03) longer.
To assess the feasibility of quantifying functional renal volume with gadolinium-enhanced magnetic resonance (MR) angiography.
Institutional review board approval was obtained, and all subjects gave ...informed consent. A contour-detection three-dimensional algorithm for determining renal volumes was developed. The method was validated in 18 cadaveric pig kidneys by measuring the water displacement caused by the kidneys. The kidney lengths and volumes in 19 consecutive potential kidney donors who underwent gadolinium-enhanced MR angiography of the renal arteries also were determined. Differences in volume measurements between men and women and between left and right kidneys were analyzed by using the Student t test. The volume of perfused renal cortex was calculated by extracting voxels on the basis of the cortex signal intensity threshold. The relevance of renal function parameters--namely, creatinine clearance rates--in the donor candidates was assessed by using a linear regression model. Intra- and interobserver variabilities of the measurements were determined by using the Bland-Altman method.
Volume measurements of the cadaveric pig kidneys obtained by using MR angiography and the water displacement method were strongly correlated (r = 0.99). The mean total renal volume in the donor candidates was 196 mL (range, 136-295 mL). No significant differences in total renal volume between the men and women or between the left and right kidneys were found. The correlation between calculated renal cortex volumes (mean, 67 mL; range, 40-105 mL) and creatinine clearance rates was good (r = 0.69). Inter- and intraobserver variabilities were lower than 7%.
Quantification of functional renal volume with three-dimensional gadolinium-enhanced MR angiography seems feasible with use of the described semiautomatic method.