In this study a semi-automated and observer-independent algorithm for quantifying post-stenotic signal loss (PSL) in three-dimensional phase-contrast (PC) magnetic resonance angiography (MRA) of ...patients with renal artery stenosis is presented. This algorithm was developed on MRA datasets of stenotic phantoms, included in a flow circuit with stationary flows. The length and the severity of the PSL (incorporating both the length and the degree of PSL) in the MRA datasets were proposed for quantifying the stenoses. The algorithm was tested in renal arteries; ten patients with renal artery stenosis and seven healthy volunteers were investigated. Digital subtraction angiography was performed in the patients and served as the gold standard. Stenosis severity showed better correlation with the severity of the PSL than with the length, both for in vitro and in vivo measurements. Spearman correlation coefficients (r
s) showed statistically significant correlations between the severity of the PSL and parameters determined by digital subtraction angiography, i.e., percent diameter stenosis (r
s = 0.90). The length of the PSL showed no correlation with the diameter stenosis (r
s = 0.37). In conclusion, this study presents a semi-automated and observer-independent way of quantifying signal loss, and the severity of the PSL is proposed for quantifying stenoses, rather than the length of PSL.
To prospectively compare the image quality and diagnostic performance achieved with doses of gadobenate dimeglumine and gadopentetate dimeglumine of 0.1 mmol per kilogram of body weight in patients ...undergoing contrast material-enhanced magnetic resonance (MR) angiography of the pelvis, thigh, and lower-leg (excluding foot) for suspected or known peripheral arterial occlusive disease.
Institutional review board approval was granted from each center and informed written consent was obtained from all patients. Between November 2006 and January 2008, 96 patients (62 men, 34 women; mean age, 63.7 years +/- 10.4 standard deviation; range, 39-86 years) underwent two identical examinations at 1.5 T by using three-dimensional spoiled gradient-echo sequences and randomized 0.1-mmol/kg doses of each agent. Images were evaluated on-site for technical adequacy and quality of vessel visualization and offsite by three independent blinded readers for anatomic delineation and detection/exclusion of pathologic features. Comparative diagnostic performance was determined in 31 patients who underwent digital subtraction angiography. Data were analyzed by using the Wilcoxon signed-rank, McNemar, and Wald tests. Interreader agreement was determined by using generalized kappa statistics. Differences in quantitative contrast enhancement were assessed and a safety evaluation was performed.
Ninety-two patients received both agents. Significantly better performance (P < .0001; all evaluations) with gadobenate dimeglumine was noted on-site for technical adequacy and vessel visualization quality and offsite for anatomic delineation and detection/exclusion of pathologic features. Contrast enhancement (P < or = .0001) and detection of clinically relevant disease (P < or = .0028) were significantly improved with gadobenate dimeglumine. Interreader agreement for stenosis detection and grading was good to excellent (kappa = 0.749 and 0.805, respectively). Mild adverse events were reported for four (six events) and five (eight events) patients after gadobenate dimeglumine and gadopentetate dimeglumine, respectively.
Higher-quality vessel visualization, greater contrast enhancement, fewer technical failures, and improved diagnostic performance are obtained with gadobenate dimeglumine, relative to gadopentetate dimeglumine, when compared intraindividually at 0.1-mmol/kg doses in patients undergoing contrast-enhanced MR angiography for suspected peripheral arterial occlusive disease.
-
mutation carriers have a 20% to 25% risk of developing pancreatic ductal adenocarcinoma (PDAC). Better understanding of the natural course of PDAC might allow the surveillance protocol to be ...improved. The aims of the study were to evaluate the role of cystic precursor lesions in the development of PDAC and to assess the growth rate. In 2000, a surveillance program was initiated, consisting of annual MRI in carriers of a
mutation. The study cohort included 204 (42% male) patients. Cystic precursor lesions were found in 52 (25%) of 204 mutation carriers. Five (9.7%) of 52 mutation carriers with cystic lesions and 8 (7.0%) of 114 mutation carriers without cystic lesions developed PDAC (
= 0.56). Three of 6 patients with a cystic lesion of ≥10 mm developed PDAC. The median size of all incident PDAC detected between 9 and 12 months since the previous normal MRI was 15 mm, suggesting an annual growth rate of about 15 mm/year. In conclusion, our findings show that patients with and without a cystic lesions have a similar risk of PDAC. However, cystic precursor lesions between 10 and 20 mm increase the risk of PDAC substantially. In view of the large size of the screen-detected tumors, a shorter interval of screening might be recommended for all patients.
.
To prospectively determine diagnostic performance and safety of contrast material-enhanced (CE) magnetic resonance (MR) angiography with 0.1 mmol per kilogram of body weight gadobenate dimeglumine ...for depiction of significant steno-occlusive disease (> or =51% stenosis) of renal arteries, with digital subtraction angiography (DSA) as reference standard.
This multicenter study was approved by local institutional review boards; all patients provided written informed consent. Patient enrollment and examination at centers in the United States complied with HIPAA. Two hundred ninety-three patients (154 men, 139 women; mean age, 61.0 years) with severe hypertension (82.2%), progressive renal failure (11.3%), and suspected renal artery stenosis (6.5%) underwent CE MR angiography with three-dimensional spoiled gradient-echo sequences after administration of 0.1 mmol/kg gadobenate dimeglumine at 2 mL/sec. Anteroposterior and oblique DSA was performed in 268 (91.5%) patients. Three independent blinded reviewers evaluated CE MR angiographic images. Sensitivity, specificity, and accuracy of CE MR angiography for detection of significant steno-occlusive disease (> or =51% vessel lumen narrowing) were determined at segment (main renal artery) and patient levels. Positive and negative predictive values and positive and negative likelihood ratios were determined. Interobserver agreement was analyzed with generalized kappa statistics. A safety evaluation (clinical examination, electrocardiogram, blood and urine analysis, monitoring for adverse events) was performed.
Of 268 patients, 178 who were evaluated with MR angiography and DSA had significant steno-occlusive disease of renal arteries at DSA. Sensitivity, specificity, and accuracy of CE MR angiography for detection of 51% or greater stenosis or occlusion were 60.1%-84.1%, 89.4%-94.7%, and 80.4%-86.9%, respectively, at segment level. Similar values were obtained for predictive values and for patient-level analyses. Few CE MR angiographic examinations (1.9%-2.8%) were technically inadequate. Interobserver agreement for detection of significant steno-occlusive disease was good (79.9% agreement; kappa = 0.69). No safety concerns were noted.
CE MR angiography performed with 0.1 mmol/kg gadobenate dimeglumine, compared with DSA, is safe and provides good sensitivity, specificity, and accuracy for detection of significant renal artery steno-occlusive disease.
The tenderness and palatability of retail and food service beef steaks from across the United States (12 cities for retail, 5 cities for food service) were evaluated using Warner-Bratzler shear (WBS) ...and consumer sensory panels. Subprimal postfabrication storage or aging times at retail establishments averaged 20.5 d with a range of 1 to 358 d, whereas postfabrication times at the food service level revealed an average time of 28.1 d with a range of 9 to 67 d. Approximately 64% of retail steaks were labeled with a packer/processor or store brand. For retail, top blade had among the lowest (P < 0.05) WBS values, whereas steaks from the round had the greatest (P < 0.05) values. There were no differences (P > 0.05) in WBS values between moist-heat and dry-heat cookery methods for the top round and bottom round steaks or between enhanced (contained salt or phosphate solution) or nonenhanced steaks. Food service top loin and rib eye steaks had the lowest (P < 0.05) WBS values compared with top sirloin steaks. Retail top blade steaks and food service top loin steaks received among the greatest (P < 0.05) consumer sensory panel ratings compared with the other steaks evaluated. Prime food service rib eye steaks received the greatest ratings (P < 0.05) for overall like, like tenderness, tenderness level, like juiciness, and juiciness level, whereas ungraded rib eye steaks received the lowest ratings (P < 0.05) for like tenderness and tenderness level. The WBS values for food service steaks were greater (P < 0.05) for the Select and ungraded groups compared with the Prime, Top Choice, and Low Choice groups. The WBS values and sensory ratings were comparable to the last survey, signifying that no recent or substantive changes in tenderness have occurred. PUBLICATION ABSTRACT
In this study, a scanning protocol was developed to image the arterial bed of the pelvis and both legs along their entire length in patients with peripheral arterial disease, using standard hard- and ...software. Three adjacent stations are acquired consecutively, with some small overlap; per station; one Gadolinium contrast bolus is administered. The scanning protocol was optimized in an in vitro phantom study. The optimal flip angle was found to be 50 degrees. Also, the optimal scan delay was chosen to be equal to the arrival time of the contrast bolus thereby minimizing artifacts. Three contrast bolus injections showed sufficient enhancement of the vessels after image subtraction. Finally, stenosis quantification by manual caliper was performed by five observers in the MRA images and correlated with the percent diameter reduction determined by quantitative angiography from corresponding X-ray images. The results of the MRA measurements were reproducible and intra- and inter-observer variabilities were statistically non-significant (p = 0.54 and p = 0.12, respectively). Stenosis quantification performed by four observers showed a good correlation with the X-ray derived values (rp > 0.90, p < 0.02); the results from one observer were not significantly correlated. Five patients with proven peripheral disease were investigated with this new MRA scanning protocol. The images were of good quality which allowed adequate clinical evaluation; the original diagnoses obtained from X-ray examinations, were confirmed with MRA. In conclusion, peripheral arterial disease can be evaluated adequately with this MR scanning protocol.
This study was conducted to determine the efficacy and safety of four different doses of gadobenate dimeglumine for contrast-enhanced three-dimensional MR angiography of the abdominal aorta and renal ...arteries.
Ninety-four patients with suspected abnormality of the abdominal aorta or renal arteries underwent unenhanced three-dimensional gradient-recalled echo time-of-flight MR angiography and contrast-enhanced MR angiography after the IV injection of one of four doses of gadobenate dimeglumine (0.025, 0.05, 0.1, and 0.2 mmol/kg of body weight). Efficacy was assessed on-site and by two blinded off-site reviewers in terms of change in total diagnostic quality score and diagnostic quality score per vessel segment from baseline unenhanced time-of-flight MR angiography to contrast-enhanced MR angiography. Secondary efficacy end points included lesion count and level of confidence in lesion characterization. Safety assessments comprised adverse event monitoring, physical evaluation, vital signs, ECG, and laboratory investigations.
A significant change in the total diagnostic quality score from unenhanced to contrast-enhanced MR angiography was observed at all doses. The change increased with increased dose, plateauing at the 0.1 mmol/kg dose level. More patients with lesions detected and increased reviewer confidence for lesion characterization were noted on contrast-enhanced MR angiography compared with unenhanced MR angiography, although no dose-related trends were observed. All doses were well tolerated, and no significant changes in safety parameters were observed.
Gadobenate dimeglumine is an effective and safe agent for contrast-enhanced MR angiography of the abdominal aorta and renal arteries. A dose of 0.1 mmol/kg of body weight appears to be the most suitable.