The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector ...have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is (2.6±0.2stat±0.4sys) ×10-3 events keV$ ee\atop{-1}$ kg-1 day-1 in a 118 kg fiducial volume. The observed background rate is (3.6±0.4stat)×10-3 events keV$ ee\atop{-1}$ kg-1 day-1, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.
Strangeness measurements with the PHOBOS experiment Veres, Gábor I; Back, B B; Baker, M D ...
Journal of physics. G, Nuclear and particle physics,
12/2006, Letnik:
32, Številka:
12
Journal Article, Conference Proceeding
An ultra-low background PMT for liquid xenon detectors Akerib, D. S.; Bai, X.; Bernard, E. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
11/2012, Letnik:
703, Številka:
C
Journal Article
Recenzirano
Odprti dostop
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, ...used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / < 8.340K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of x $\frac{1}{24}$ 238U / x $\frac{1}{9}$ 232Th / x $\frac{1}{8}$ 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of x $\frac{1}{25}$ after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times $\frac{1}{36}$. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
Observation of rotational curve of spiral galaxies shows that a large fraction (∼23%) of the mass density of the universe is unaccounted for. Such a significant percentage of missing dark matter ...suggests that the universe may consist of new types of elementary particles. A compelling explanation for the new particles is the existence of Weakly Interacting Massive Particles (WIMPs), which are non-baryonic particles characterized by particle physics theories beyond the Standard Model. WIMPs are believed to only interact through the weak force and gravity; hence the interaction cross section with ordinary matter is extremely small. Therefore, experimental techniques that combine low radioactivity, low energy thresholds, efficient discrimination against electronic recoil backgrounds, and scalability to large detector masses can only be performed at a deep underground environment where the interference of cosmic rays is obviated. In this paper, we report a cryogenic large liquid xenon detector for dark matter searches at Sanford Lab (Davis Cavern) in the Homestake Mine, USA. The goal of the large underground xenon (LUX) dual-phase detector is to clearly detect (or exclude) WIMPs with a spin independent cross-section per nucleon of 7 × 10−46 cm2, equivalent to ∼0.5 events/100 kg/month in an inner 100 kg fiducial volume (FV) of a 300 kg LXe detector.
The Large Underground Xenon (LUX) experiment Akerib, D. S.; Bai, X.; Bedikian, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
11/2012, Letnik:
704, Številka:
C
Journal Article
Recenzirano
Odprti dostop
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles (WIMPs), a leading dark ...matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross-section per nucleon of 2×10-46 cm2, equivalent to ∼1event/100kg/month in the inner 100-kg fiducial volume (FV) of the 370-kg detector. The overall background goals are set to have <1 background events characterized as possible WIMPs in the FV in 300 days of running. This paper describes the design and construction of the LUX detector.
Data acquisition and readout system for the LUX dark matter experiment Akerib, D. S.; Bai, X.; Bedikian, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
11/2011, Letnik:
668, Številka:
C
Journal Article
Recenzirano
Odprti dostop
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by ...custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This work describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.
To provide an overview of the demographics, treatment characteristics and long-term outcomes of children with perinatal HIV-1 infection (PHIV) living in the Netherlands (NL) and to specifically ...investigate whether outcomes differ by children's adoption status.
A prospective population-based open cohort including children with PHIV in NL.
We included children with PHIV who had entered HIV care in NL since 2007, in view of a sharp increase in the number of adopted children with PHIV since that year. We compared the proportion with virologic suppression and CD4+T-cell count over time between the following groups of children with PHIV: adopted and born outside NL, non-adopted born in NL, and non-adopted born outside NL, using generalized estimating equations and linear mixed effects models, respectively. To account for the variation in cohort inclusion, we analyzed data of children exposed to at least one year of antiretroviral therapy (ART).
We included 148 children (827.5 person-years of follow-up, 72% adopted, age at start care in NL 2.4 (0.5-5.3)). Under-18 mortality was zero. Over the years, a boosted PI-based regimen was most often prescribed. The use of integrase inhibitors increased since 2015. Non-adopted children born in NL were less likely to achieve virological suppression compared to adopted children (OR 0.66, 95%CI 0.51-0.86, p = 0.001), which disappeared after excluding one child with suspected treatment nonadherence (OR 0.85, 95%CI 0.57-1.25, p = 0.400). CD4+T-cell Z-score trajectories were not significantly different between groups.
Despite considerable and increasing diversity of the population of children with PHIV in NL, geographical origin and adoption status do not seem to pose important challenges in achieving good immunological and virological outcomes.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK