In the TRITIUM project, an on-site monitoring system is being developed to measure tritium (3H) levels in water near nuclear power plants. The quite low-energy betas emitted by 3H have a very short ...average path in water (5 μm as shown by simulations for 18 keV electrons). This path would be further reduced by impurities present in the water, resulting in a significant reduction of the detection efficiency. Therefore, one of the essential requirements of the project is the elimination of these impurities through a filtration process and the removal of salts in solution. This paper describes a water treatment system developed for the project that meets the following requirements: the water produced should be of near-pure water quality according to ISO 3696 grade 3 standard (conductivity < 10 μS/cm); the system should operate autonomously and be remotely monitored.
Simulation results of a real-time in water tritium monitor Azevedo, C.D.R.; Baeza, A.; Chauveau, E. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2020, Letnik:
982
Journal Article
Recenzirano
Odprti dostop
In this work we present simulation results for a modular tritium in-water real-time monitor. The system allows for scalability in order to achieve the required sensitivity. The modules are composed ...by 340 uncladed scintillating fibers immersed in water and 2 photosensors in coincidence for light readout. Light yield and Birks’ coefficient uncertainties for low energy beta particles is discussed. A study of the detection efficiency according to the fiber length is presented. Discussion on the system requirements and background mitigation for a device with sensitivity of 100Bq/L, required to comply with the European directive 2013/51/Euratom, is presented. Due to the low energetic beta emission from tritium a detection efficiency close to 3.3% was calculated for a single 2 mm round fiber.
Abstract
In this paper, we report the development and performance of
a detector module envisaging a tritium-in-water real-time activity
monitor. The monitor is based on modular detection units whose
...number can be chosen according to the required sensitivity. The full
system is being designed to achieve a
Minimum Detectable
Activity
(
MDA
) of 100 Bq/L of tritium-in-water activity
which is the limit established by the E.U. Council Directive
2013/51/Euratom for water intended for human consumption. The same
system can be used as a real-time pre-alert system for nuclear power
plant regarding tritium-in water environmental surveillance. The
first detector module was characterized, commissioned and installed
immediately after the discharge channel of the Arrocampo dam
(Almaraz nuclear power plant, Spain) on the Tagus river. Due to the
high sensitivity of the single detection modules, the system
requires radioactive background mitigation techniques through the
use of active and passive shielding. We have extrapolated a
MDA
of 3.6 kBq/L for a single module being this value
limited by the cosmic background. The obtained value for a single
module is already compatible with a real-time environmental
surveillance and pre-alert system. Further optimization of the
single-module sensitivity will imply the reduction of the number of
modules and the cost of the detector system.
Tritium is released abundantly to the environment by nuclear power plants (NPP), as a product of neutron capture by hydrogen and deuterium. In normal running conditions, released cooling waters may ...contain levels of tritium close to or even larger than the maximum authorised limit for human consumption (drinking and irrigation). The European Council Directive 2013/51/Euratom requires a maximum level of tritium in water for human consumption lower than 100 Bq=L. Current monitoring of tritium activity in water by liquid scintillating method takes about two days and can only be carried out in a dedicated laboratory. This system is not appropriate for real time monitoring. At present, there exists no available detector device with enough sensitivity to monitor waters for human consumption with high enough sensitivity. The goal of the TRITIUM project is to build a tritium monitor capable to measure tritium activities with detection limit close to 100Bq=L, using instrumentation technique developed in recent years for Nuclear and Particle Physics, such as scintillating fibres and silicon photomultipliers (SiPM). In this paper the current status of the TRITIUM project is presented and he results of first prototypes are discussed. A detector system based on scintillating fibers read out either photomultiplier tubes (PMTs) or silicon photomultiplier (SiPM) arrays is under development and will be installed in the vicinity of Almaraz nuclear power plant (Cáceres, Spain) by the fourth term of 2019.
Noble gases (Xe, Ar, Kr) are very attractive as detector media in Dark Matter search and neutrinoless double-beta decay experiments. However, the detection of their scintillation light (in the VUV ...spectral region) requires shifting the VUV light to visible light, where standard photosensors are more efficient. Tetraphenyl butadiene (TPB) is widely used as wavelength shifter, absorbing the VUV light and re-emitting in the blue region (~430nm). TPB is an organic molecule that may degrade due to exposure to environmental agents and also to ultraviolet light. In this work, we present TPB ageing studies due to exposure to VUV light, aiming at quantifying the reduction of the absolute fluorescence yield of TPB coatings of several thicknesses (130nm, 260nm, 390nm, 1600nm), exposed to various doses of VUV light at 170nm (similar to the Xe scintillation). In our setup, the VUV light is produced from a vacuum monochromator coupled to a deuterium lamp. The VUV exposure in our setup is compared to the exposure obtained in the electroluminescent gaseous Xe TPC of the NEXT-100 experiment for neutrinoless double-beta decay search.
•TPB coatings of various thicknesses are exposed to controlled VUV light at 170nm.•The VUV exposure of the TPB is normalized to that expected in a real EL TPC.•The absolute fluorescence efficiency of the TPB coatings is measured.•The reduction of the efficiency is <15% for the thick TPB coating.
NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current configuration the ...apparatus fully implements the NEXT-100 design concept. This is an asymmetric TPC, with an energy plane made of photomultipliers and a tracking plane made of silicon photomultipliers (SiPM) coated with TPB. The detector in this new configuration has been used to reconstruct the characteristic signature of electrons in dense gas, demonstrating the ability to identify the MIP and "blob" regions. Moreover, the SiPM tracking plane allows for the definition of a large fiducial region in which an excellent energy resolution of 1.82% FWHM at 511 keV has been measured (a value which extrapolates to 0.83% at the xenon Q sub( beta beta )).
NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of super(136)Xe using 100-150 kg ...of enriched xenon gas. NEXT-DEMO was built to prove the expected performance of NEXT-100, namely, energy resolution better than 1% FWHM at 2.5MeV and event topological reconstruction. In this paper we describe the prototype and its initial results. A resolution of 1.75% FWHM at 511 keV (which extrapolates to 0.8% FWHM at 2.5 MeV) was obtained at 10 bar pressure using a gamma-ray calibration source. Also, a basic study of the event topology along the longitudinal coordinate is presented, proving that it is possible to identify the distinct dE/dx of electron tracks in high-pressure xenon using an electroluminescence TPC.
A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift x 28 cm diameter, it constitutes the largest Micromegas-read TPC ...operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (~231) so as to contain long (~20 cm) electron tracks. First results obtained at 1 bar for Xenon and Trymethylamine (Xe-(2%)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging full-width half-maximum of 11.6% was obtained for ~ 29 keV gammas without resorting to any data post-processing.
Silicon photomultipliers (SiPMs) are photosensors widely used for imaging in a variety of high energy and nuclear physics experiments. In noble-gas detectors for double-beta decay and dark matter ...experiments, SiPMs are attractive photosensors for imaging. However they are insensitive to the VUV scintillation emitted by the noble gases (xenon and argon). This difficulty is overcome in the NEXT experiment by coating the SiPMs with tetraphenyl butadiene (TPB) to convert the VUV light into visible light. TPB requires stringent storage and operational conditions to prevent its degradation by environmental agents. The development of UV sensitive SiPMs is thus of utmost interest for experiments using electroluminescence of noble-gas detectors. It is in particular an important issue for a robust and background free beta beta 0 upsilon experiment with xenon gas aimed by NEXT. The photon detection efficiency (PDE) of UV-enhanced SiPMs provided by Hamamatsu was determined for light in the range 250-500 nm. The PDE of standard SiPMs of the same model (S10362-33-50C), coated and non-coated with TPB, was also determined for comparison. In the UV range 250-350 nm, the PDE of the standard SiPM is shown to decrease strongly, down to about 3%. The UV-enhanced SiPM without window is shown to have the maximum PDE of 44% at 325 nm and 30% at 250 nm. The PDE of the UV-enhanced SiPM with silicon resin window has a similar trend in the UV range, although it is about 30% lower. The TPB-coated SiPM has shown to have about 6 times higher PDE than the non-coated SiPM in the range 250-315 nm. This is however below the performance of the UV-enhanced prototypes in the same wavelength range. Imaging in noble-gas detectors using UV-enhanced SiPMs is discussed.