The RENO experiment reports more precisely measured values of θ_{13} and |Δm_{ee}^{2}| using ∼2200 live days of data. The amplitude and frequency of reactor electron antineutrino (νover ¯_{e}) ...oscillation are measured by comparing the prompt signal spectra obtained from two identical near and far detectors. In the period between August 2011 and February 2018, the far (near) detector observed 103 212 (850 666) νover ¯_{e} candidate events with a background fraction of 4.8% (2.0%). A clear energy and baseline dependent disappearance of reactor νover ¯_{e} is observed in the deficit of the measured number of νover ¯_{e}. Based on the measured far-to-near ratio of prompt spectra, we obtain sin^{2}2θ_{13}=0.0896±0.0048(stat)±0.0047(syst) and |Δm_{ee}^{2}|=2.68±0.12(stat)±0.07(syst)×10^{-3} eV^{2}.
Summary
Background
Asthma in the elderly (aged ≥ 65 years old) is a significant concern with high morbidity, but the pathophysiology remains unclear particularly in late‐onset asthma. Recent studies ...suggest staphylococcal enterotoxin IgE (SE‐IgE) sensitization to be a risk factor for asthma in general populations; however, the associations have not been examined in late‐onset elderly asthma.
Objective
We aimed to examine the associations of SE‐IgE sensitization with late‐onset asthma in the elderly, using a database of elderly asthma cohort study.
Methods
A total of 249 elderly patients with asthma and 98 controls were analysed. At baseline, patients were assessed for demographics, atopy, induced sputum profiles and comorbidities including chronic rhinosinusitis (CRS). Serum total IgE and SE‐IgE levels were measured. Asthma severity was assessed on the basis of asthma outcomes during a 12‐month follow‐up period.
Results
At baseline, serum SE‐IgE concentrations were significantly higher in patients with asthma than in controls median 0.16 (interquartile range 0.04–0.53) vs. 0.10 (0.01–0.19), P < 0.001. Elderly asthma patients with high SE‐IgE levels had specific characteristics of having more severe asthma, sputum eosinophilia and CRS, compared to those with lower SE‐IgE levels. In multivariate logistic regression analyses, the associations between serum SE‐IgE concentrations and severe asthma were significant, independently of covariables SE‐IgE‐high (≥ 0.35 kU/L) vs. negative (< 0.10 kU/L) group: odds ratio 7.47, 95% confidence interval 1.86–30.03, P = 0.005. Multiple correspondence analyses also showed that high serum SE‐IgE level had close relationships with severe asthma, CRS and sputum eosinophilia together.
Conclusions and Clinical Relevance
This is the first report on the significant associations of SE‐IgE sensitization with late‐onset asthma in the elderly, particularly severe eosinophilic asthma with CRS comorbidity. Our findings indicate a potential implication of SE in the high morbidity burden of elderly asthma and suggest clues to the pathogenesis of severe late‐onset eosinophilic asthma in the elderly.
The Reactor Experiment for Neutrino Oscillation (RENO) has been taking electron antineutrino (ν¯e) data from the reactors in Yonggwang, Korea, using two identical detectors since August 2011. Using ...roughly 500 live days of data through January 2013 we observe 290 775 (31 514) reactor ν¯e candidate events with 2.8% (4.9%) background in the near (far) detector. The observed visible positron spectra from the reactor ν¯e events in both detectors show a discrepancy around 5 MeV with regard to the prediction from the current reactor ν¯e model. Based on a far-to-near ratio measurement using the spectral and rate information, we have obtained sin22θ13=0.082±0.009(stat.)±0.006(syst.) and |Δmee2|=2.62−0.23+0.21(stat.)−0.13+0.12(syst.)×10−3 eV2.
The RENO experiment has observed the disappearance of reactor electron antineutrinos, consistent with neutrino oscillations, with a significance of 4.9 standard deviations. Antineutrinos from six 2.8 ... GW(th) reactors at the Yonggwang Nuclear Power Plant in Korea, are detected by two identical detectors located at 294 and 1383 m, respectively, from the reactor array center. In the 229 d data-taking period between 11 August 2011 and 26 March 2012, the far (near) detector observed 17102 (154088) electron antineutrino candidate events with a background fraction of 5.5% (2.7%). The ratio of observed to expected numbers of antineutrinos in the far detector is 0.920±0.009(stat)±0.014(syst). From this deficit, we determine sin(2)2θ(13)=0.113±0.013(stat)±0.019(syst) based on a rate-only analysis.
An outstanding goal in quantum optics and scalable photonic quantum technology is to develop a source that each time emits one and only one entangled photon pair with simultaneously high entanglement ...fidelity, extraction efficiency, and photon indistinguishability. By coherent two-photon excitation of a single InGaAs quantum dot coupled to a circular Bragg grating bull's-eye cavity with a broadband high Purcell factor of up to 11.3, we generate entangled photon pairs with a state fidelity of 0.90(1), pair generation rate of 0.59(1), pair extraction efficiency of 0.62(6), and photon indistinguishability of 0.90(1) simultaneously. Our work will open up many applications in high-efficiency multiphoton experiments and solid-state quantum repeaters.
A novel concept for integrating visible light communications (VLC) with three‐dimensional indoor positioning is presented. A VLC link based on transmitter and receiver characteristics using ...experimental measurements was modelled. Proposed is a three‐dimensional positioning algorithm using received signal strength indication, which changes based on the angle and distance of the location based service. To reduce inter‐cell interference, the transmitter's location code was sent using different subcarriers. A demonstration shows that the proposed algorithm can obtain a user's position, including height, accurately and without inter‐cell interference.
Summary
Although different injection locations for retrolaminar and erector spinae plane blocks have been described, the two procedures have a similar anatomical basis. In this cadaveric study we ...compared anatomical spread of dye in the thoracic region following these two procedures. Following randomisation, 10 retrolaminar blocks and 10 erector spinae plane blocks were performed on the left or right sides of 10 unembalmed cadavers. For each block, 20 ml of dye solution was injected at the T5 level. The back regions were dissected and the involvement of the thoracic spinal nerve was also investigated. Twenty blocks were successfully completed. A consistent vertical spread, with deep staining between the posterior surface of the vertebral laminae and the overlaying transversospinalis muscle was observed in all retrolaminar blocks. Moreover, most retrolaminar blocks were predominantly associated with fascial spreading in the intrinsic back muscles. With an erector spinae plane block, dye spread in a more lateral pattern than with retrolaminar block, and fascial spreading in the back muscles was also observed. The number of stained thoracic spinal nerves was greater with erector spinae plane blocks than with retrolaminar blocks; median 2.0 and 3.5, respectively. Regardless of technique, the main route of dye spread was through the superior costotransverse ligament to the ipsilateral paravertebral space. Although erector spinae plane blocks were associated with a slightly larger number of stained thoracic spinal nerves than retrolaminar blocks, both techniques were consistently associated with posterior spread of dye and with limited spread to the paravertebral space.
Neuromorphic visual systems have considerable potential to emulate basic functions of the human visual system even beyond the visible light region. However, the complex circuitry of artificial visual ...systems based on conventional image sensors, memory and processing units presents serious challenges in terms of device integration and power consumption. Here we show simple two-terminal optoelectronic resistive random access memory (ORRAM) synaptic devices for an efficient neuromorphic visual system that exhibit non-volatile optical resistive switching and light-tunable synaptic behaviours. The ORRAM arrays enable image sensing and memory functions as well as neuromorphic visual pre-processing with an improved processing efficiency and image recognition rate in the subsequent processing tasks. The proof-of-concept device provides the potential to simplify the circuitry of a neuromorphic visual system and contribute to the development of applications in edge computing and the internet of things.