Quasi‐biennial oscillations (QBOs) in thirteen atmospheric general circulation models forced with both observed and annually repeating sea surface temperatures (SSTs) are evaluated. In most models ...the QBO period is close to, but shorter than, the observed period of 28 months. Amplitudes are within ±20% of the observed QBO amplitude at 10 hPa, but typically about half of that observed at lower altitudes (50 and 70 hPa). For almost all models, the oscillation's amplitude profile shows an overall upward shift compared to reanalysis and its meridional extent is too narrow. Asymmetry in the duration of eastward and westward phases is reasonably well captured, though not all models replicate the observed slowing of the descending westward shear. Westward phases are generally too weak, and most models have an eastward time mean wind bias throughout the depth of the QBO. The intercycle period variability is realistic and in some models is enhanced in the experiment with observed SSTs compared to the experiment with repeated annual cycle SSTs. Mean periods are also sensitive to this difference between SSTs, but only when parametrized non‐orographic gravity wave (NOGW) sources are coupled to tropospheric parameters and not prescribed with a fixed value. Overall, however, modelled QBOs are very similar whether or not the prescribed SSTs vary interannually. A portrait of the overall ensemble performance is provided by a normalized grading of QBO metrics. To simulate a QBO, all but one model used parametrized NOGWs, which provided the majority of the total wave forcing at altitudes above 70 hPa in most models. Hence the representation of NOGWs either explicitly or through parametrization is still a major uncertainty underlying QBO simulation in these present‐day experiments.
Quasi‐biennial oscillations (QBOs) in thirteen atmospheric general circulation models forced with both observed (orange) and annually repeating (grey) sea surface temperatures (SSTs) are evaluated over a range of metrics and compared against reanalysis (blue‐green). Mean periods are sensitive to this difference between SSTs, but only when parametrized non‐orographic gravity wave sources are coupled to tropospheric parameters (60LCAM5 and right there of) and not prescribed with fixed values. Overall, however, modelled QBOs are very similar whether or not the prescribed SSTs vary interannually.
The Quasi‐Biennial Oscillation initiative (QBOi) is a model intercomparison programme that specifically targets simulation of the QBO in current global climate models. Eleven of the models or model ...versions that participated in a QBOi intercomparison study have upper boundaries in or above the mesosphere and therefore simulate the region where the stratopause semiannual oscillation (SAO) is the dominant mode of variability of zonal winds in the tropical upper stratosphere. Comparisons of the SAO simulations in these models are presented here. These show that the model simulations of the amplitudes and phases of the SAO in zonal‐mean zonal wind near the stratopause agree well with the information derived from available observations. However, most of the models simulate time‐average zonal winds that are more westward than determined from observations, in some cases by several tens of m·s–1. Validation of wave activity in the models is hampered by the limited observations of tropical waves in the upper stratosphere but suggests a deficit of eastward forcing either by large‐scale waves, such as Kelvin waves, or by gravity waves.
The figure shows the climatological annual cycle of equatorial zonally averaged zonal wind for each calendar month from 11 models that participated in the Quasi‐Biennial Oscillation initiative (QBOi), compared with winds derived from SABER observations (lower right). The models simulate a realistic semiannual cycle but the time‐mean winds are more strongly westward than observed.
Elderly patients with atrial fibrillation who were not appropriate candidates for standard doses of oral anticoagulants because of a high risk of bleeding were assigned to receive 15 mg of edoxaban ...or placebo once daily. Edoxaban was superior to placebo in preventing stroke or systemic embolism.
Abstract Gravity‐wave (GW) parameterizations from 12 general circulation models (GCMs) participating in the Quasi‐Biennial Oscillation initiative (QBOi) are compared with Strateole 2 balloon ...observations made in the tropical lower stratosphere from November 2019–February 2020 (phase 1) and from October 2021–January 2022 (phase 2). The parameterizations employ the three standard techniques used in GCMs to represent subgrid‐scale non‐orographic GWs, namely the two globally spectral techniques developed by Warner and McIntyre (1999) and Hines (1997), as well as the “multiwaves” approaches following the work of Lindzen (1981). The input meteorological fields necessary to run the parameterizations offline are extracted from the ERA5 reanalysis and correspond to the meteorological conditions found underneath the balloons. In general, there is fair agreement between amplitudes derived from measurements for waves with periods less than h and parameterizations. The correlation between the daily observations and the corresponding results of the parameterization can be around 0.4, which is significant, since 1200 days of observations are used. Given that the parameterizations have only been tuned to produce a quasi‐biennial oscillation (QBO) in the models, the 0.4 correlation coefficient of the GW momentum fluxes is surprisingly good. These correlations nevertheless vary between schemes and depend little on their formulation (globally spectral versus multiwaves for instance). We therefore attribute these correlations to dynamical filtering, which all schemes take into account, whereas only a few relate the gravity waves to their sources. Statistically significant correlations are mostly found for eastward‐propagating waves, which may be due to the fact that during both Strateole 2 phases the QBO is easterly at the altitude of the balloon flights. We also found that the probability density functions (pdfs) of the momentum fluxes are represented better in spectral schemes with constant sources than in schemes (“spectral” or “multiwaves”) that relate GWs only to their convective sources.
Measurements of spin excitations are essential for an understanding of spin-mediated pairing for superconductivity; and resonant inelastic X-ray scattering (RIXS) provides a considerable opportunity ...to probe high-energy spin excitations. However, whether RIXS correctly measures the collective spin excitations of doped superconducting cuprates remains under debate. Here we demonstrate distinct Raman- and fluorescence-like RIXS excitations of Bi1.5Pb0.6Sr1.54CaCu2O(8+δ). Combining photon-energy and momentum dependent RIXS measurements with theoretical calculations using exact diagonalization provides conclusive evidence that the Raman-like RIXS excitations correspond to collective spin excitations, which are magnons in the undoped Mott insulators and evolve into paramagnons in doped superconducting compounds. In contrast, the fluorescence-like shifts are due primarily to the continuum of particle-hole excitations in the charge channel. Our results show that under the proper experimental conditions RIXS indeed can be used to probe paramagnons in doped high-Tc cuprate superconductors.
First search for KL → π0γ Shimizu, N
Physical review. D,
09/2020, Letnik:
102, Številka:
5
Journal Article
Recenzirano
We report the first search for the KL → π0γ decay, which is forbidden by Lorentz invariance, using the data from 2016 to 2018 at the J-PARC KOTO experiment. With a single event sensitivity of (7.1 ± ...0. 3stat ± 1. 6syst) × 10−8, no candidate event was observed in the signal region. The upper limit on the branching fraction was set to be 1.7 × 10−7 at the 90% confidence level.
In this paper we describe the Kottamia Faint Imaging Spectro-Polarimeter (KFISP) that has been recently developed and designed to be mounted at the Cassegrain focus of the 1.88 m telescope at ...Kottamia Astronomical Observatory (KAO), Egypt. The optical design of KFISP is developed such that it can be used in various modes of operation. These are: direct imaging, spectroscopic, polarimetric imaging, and spectro-polarimetric. The KFISP is an all-refractive design to meet the polarimetric requirements and includes a focal reducer with a corrector section, collimator section, parallel beam section (containing various imaging components), and camera section. The corrector section gives an unvignetted Field-of-View of 8ʹ × 8ʹ and the collimator section has a focal length of 305 mm and matches the focal ratio of the input beam. The parallel beam section is 200 mm long and near the middle of it there is an image of the telescope pupil. The camera section includes 5 elements and has a focal length of 154.51 mm which gives an instrument effective final focal ratio of f/6.14 (acting as a telescope focal reducer of 1:2 ratio). The KFISP contains an internal calibration system which hosts the calibration light injection system, an integrating sphere equipped with the required calibration light sources. The opto-mechanical parts of KFISP contain a double-layered carbon fiber strut structure and comprises its subsystems of slit and guider assemblies, filter wheel drawer, grism wheel drawer, polarimetric components cubical box, and CCD camera which is integrated with camera optics. The CCD camera has 2048
×
2048 pixels with 13.5-micron square pixel size. The camera is cooled by liquid Nitrogen and is fixed to the KFISP through the integrated camera lens. The KFISP has been fully commissioned, mounted and is being tested in all modes of operation. In this paper we introduce the ambitious scientific goals, the optical setups of KFISP, its opto-mechanical implementation and the performance analysis of the instrument. In addition, we describe the camera system, its performance, and its software control. Finally, we present a sample of the first light observations obtained from the instrument.