It is now known that single-monochromator Brewer spectrophotometer ozone and sulfur dioxide measurements suffer from non-linearity at large ozone slant column amounts due to the presence of ...instrumental stray light caused by scattering within the optics of the instrument. Because of the large gradient in the ozone absorption spectrum in the near-ultraviolet, the atmospheric spectra measured by the instrument possess a very large gradient in intensity in the 300 to 325 nm wavelength region. This results in a significant sensitivity to stray light when there is more than 1000 Dobson units (DU) of ozone in the light path. As the light path (air mass) through ozone increases, the stray-light effect on the measurements also increases. The measurements can be of the order of 10 %, low for an ozone column of 600 DU and an air mass factor of 3 (1800 DU slant column amount), which is an example of conditions that produce large slant column amounts.
The MOPITT (Measurements Of Pollution In The Troposphere) instrument has been providing continuous measurements of carbon monoxide (CO) total column and CO vertical profile on a global scale since ...its launch on the Terra spacecraft on 18th of December 1999. MOPITT was one of the first correlation radiometer instruments at the time of its launch, that utilizes a combination of Length Modulating Cells (LMCs), Pressure Modulating Cells (PMCs) and Stirling cryocoolers to observe CO in the troposphere from space. MOPITT is unique in that it is the only space-borne correlation radiometer instrument in current operation that measures CO in the atmosphere. After 20 years of operation, an overview of the telemetry of MOPITT provides significant insight into the performance of one of the longest operating satellite instruments in the space environment.
In this work, the engineering telemetry of MOPITT’s core subsystems is examined, with emphasis on their relation to MOPITT’s long-term successes. These instrument successes include: (1) achieving an extremely stable thermal and vibrational environment; (2) allowing for compensation of subsystem failures and anomalies by means of a redundant design; (3) maintaining stable detector performance; and (4) becoming the longest living operational instrument for measuring atmospheric CO columns and profiles.
Dobson and Brewer spectrophotometers are the primary, standard instruments for ground-based ozone measurements under the World Meteorological Organization's (WMO) Global Atmosphere Watch program. The ...accuracy of the data retrieval for both instruments depends on a knowledge of the ozone absorption coefficients and some assumptions underlying the data analysis. Instrumental stray light causes nonlinearity in the response of both the Brewer and Dobson to ozone at large ozone slant paths. In addition, it affects the effective ozone absorption coefficients and extraterrestrial constants that are both instrument-dependent. This effect has not been taken into account in the calculation of ozone absorption coefficients that are currently recommended by WMO for the Dobson network. The ozone absorption coefficients are calculated for each Brewer instrument individually, but in the current procedure the effect of stray light is not considered. This study documents the error caused by the effect of stray light in the Brewer and Dobson total ozone measurements using a physical model for each instrument. For the first time, new ozone absorption coefficients are calculated for the Brewer and Dobson instruments, taking into account the stray light effect. The analyses show that the differences detected between the total ozone amounts deduced from Dobson AD and CD pair wavelengths are related to the level of stray light within the instrument. The discrepancy introduced by the assumption of a fixed height for the ozone layer for ozone measurements at high latitude sites is also evaluated. The ozone data collected by two Dobson instruments during the period of December 2008 to December 2014 are compared with ozone data from a collocated double monochromator Brewer spectrophotometer (Mark III). The results illustrate the dependence of Dobson AD and CD pair measurements on stray light.
AIM-North is a proposed satellite mission that would provide observations of unprecedented frequency and density for monitoring northern greenhouse gases (GHGs), air quality (AQ) and vegetation. ...AIM-North would consist of two satellites in a highly elliptical orbit formation, observing over land from ∼40°N to 80°N multiple times per day. Each satellite would carry a near-infrared to shortwave infrared imaging spectrometer for CO
2
, CH
4
, and CO, and an ultraviolet-visible imaging spectrometer for air quality. Both instruments would measure solar-induced fluorescence from vegetation. A cloud imager would make near-real-time observations, which could inform the pointing of the other instruments to focus only on the clearest regions. Multiple geostationary (GEO) AQ and GHG satellites are planned for the 2020s, but they will lack coverage of northern regions like the Arctic. AIM-North would address this gap with quasi-geostationary observations of the North and overlap with GEO coverage to facilitate intercomparison and fusion of these datasets. The resulting data would improve our ability to forecast northern air quality and quantify fluxes of GHG and AQ species from forests, permafrost, biomass burning and anthropogenic activity, furthering our scientific understanding of these processes and supporting environmental policy.