Background
Postoperative complications have a great impact on the postoperative course and oncological outcomes following major cancer surgery. Among them, infective complications play an important ...role. The aim of this study was to evaluate whether postoperative infective complications influence long‐term survival after liver resection for hepatocellular carcinoma (HCC).
Methods
Patients who underwent resection with curative intent for HCC between July 2003 and June 2016 were identified from a multicentre database (8 institutions) and analysed retrospectively. Independent risk factors for postoperative infective complications were identified. After excluding patients who died 90 days or less after surgery, overall survival (OS) and recurrence‐free survival (RFS) were compared between patients with and without postoperative infective complications within 30 days after resection.
Results
Among 2442 patients identified, 332 (13·6 per cent) had postoperative infective complications. Age over 60 years, diabetes mellitus, obesity, cirrhosis, intraoperative blood transfusion, duration of surgery exceeding 180 min and major hepatectomy were identified as independent risk factors for postoperative infective complications. Univariable analysis revealed that median OS and RFS were poorer among patients with postoperative infective complications than among patients without (54·3 versus 86·8 months, and 22·6 versus 43·2 months, respectively; both P < 0·001). After adjustment for other prognostic factors, multivariable Cox regression analyses identified postoperative infective complications as independently associated with decreased OS (hazard ratio (HR) 1·20, 95 per cent c.i. 1·02 to 1·41; P = 0·027) and RFS (HR 1·19, 1·03 to 1·37; P = 0·021).
Conclusion
Postoperative infective complications decreased long‐term OS and RFS in patients treated with liver resection for HCC.
From a multi‐institutional database, 2442 patients who underwent resection with curative intent for hepatocellular carcinoma between 2003 and 2016 were analysed retrospectively. Among them, 332 patients (13·6 per cent) had postoperative infective complications within 30 days after surgery. Multivariable Cox regression revealed that postoperative infective complications decreased long‐term overall and recurrence‐free survival after liver resection for hepatocellular carcinoma.
Complications decrease long‐term overall survival
Fast radio bursts (FRBs) are millisecond-duration radio transients of unknown physical origin observed at extragalactic distances
. It has long been speculated that magnetars are the engine powering ...repeating bursts from FRB sources
, but no convincing evidence has been collected so far
. Recently, the Galactic magnetar SRG 1935+2154 entered an active phase by emitting intense soft γ-ray bursts
. One FRB-like event with two peaks (FRB 200428) and a luminosity slightly lower than the faintest extragalactic FRBs was detected from the source, in association with a soft γ-ray/hard-X-ray flare
. Here we report an eight-hour targeted radio observational campaign comprising four sessions and assisted by multi-wavelength (optical and hard-X-ray) data. During the third session, 29 soft-γ-ray repeater (SGR) bursts were detected in γ-ray energies. Throughout the observing period, we detected no single dispersed pulsed emission coincident with the arrivals of SGR bursts, but unfortunately we were not observing when the FRB was detected. The non-detection places a fluence upper limit that is eight orders of magnitude lower than the fluence of FRB 200428. Our results suggest that FRB-SGR burst associations are rare. FRBs may be highly relativistic and geometrically beamed, or FRB-like events associated with SGR bursts may have narrow spectra and characteristic frequencies outside the observed band. It is also possible that the physical conditions required to achieve coherent radiation in SGR bursts are difficult to satisfy, and that only under extreme conditions could an FRB be associated with an SGR burst.
Fast radio bursts (FRBs) are highly dispersed, millisecond-duration radio bursts1-3. Recent observations of a Galactic FRB4-8 suggest that at least some FRBs originate from magnetars, but the origin ...of cosmological FRBs is still not settled. Here we report the detection of1,863 bursts in 82 h over 54 days from the repeating source FRB 20201124A (ref.9). These observations show irregular short-time variation ofthe Faraday rotation measure (RM), which scrutinizes the density-weighted line-of-sight magnetic field strength, of individual bursts during the first 36 days, followed by a constant RM. We detected circular polarization in more than half of the burst sample, including one burst reaching a high fractional circular polarization of 75%. Oscillations in fractional linear and circular polarizations, as well as polarization angle as a function of wavelength, were detected. All of these features provide evidence for a complicated, dynamically evolving, magnetized immediate environment within about an astronomical unit (au; Earth-Sun distance) ofthe source. Our optical observations of its Milky-Way-sized, metal-rich host galaxy10-12 show a barred spiral, with the FRB source residing in a low-stellar-density interarm region at an intermediate galactocentric distance. This environment is inconsistent with a young magnetar engine formed during an extreme explosion of a massive star that resulted in a long gamma-ray burst or superluminous supernova.
Fast radio bursts (FRBs) are millisecond-duration radio transients
of unknown origin. Two possible mechanisms that could generate extremely coherent emission from FRBs invoke neutron star ...magnetospheres
or relativistic shocks far from the central energy source
. Detailed polarization observations may help us to understand the emission mechanism. However, the available FRB polarization data have been perplexing, because they show a host of polarimetric properties, including either a constant polarization angle during each burst for some repeaters
or variable polarization angles in some other apparently one-off events
. Here we report observations of 15 bursts from FRB 180301 and find various polarization angle swings in seven of them. The diversity of the polarization angle features of these bursts is consistent with a magnetospheric origin of the radio emission, and disfavours the radiation models invoking relativistic shocks.
Gravitational‐wave high‐energy Electromagnetic Counterpart All‐sky Monitor (GECAM) is a space‐borne instrument dedicated to monitoring high‐energy transients, including Terrestrial Gamma‐ray Flashes ...(TGFs) and Terrestrial Electron Beams (TEBs). We implemented a TGF/TEB search algorithm for GECAM, with which 147 bright TGFs, 2 typical TEBs and 2 special TEB‐like events are identified during an effective observation time of ∼9 months. We show that, with gamma‐ray and charged particle detectors, GECAM can effectively identify and distinguish TGFs and TEBs, and measure their temporal and spectral properties in detail. A very high TGF‐lightning association rate of ∼80% is obtained between GECAM and GLD360 in east Asia region.
Plain Language Summary
Terrestrial gamma‐ray flashes (TGFs) and Terrestrial Electron Beams (TEBs) represent the most energetic radioactive phenomena in the atmosphere of the Earth. They reflect a natural particle accelerator that can boost electrons up to at least several tens of mega electron volts and produce gamma‐ray radiation. With novel detection technologies, Gravitational‐wave high‐energy Electromagnetic Counterpart All‐sky Monitor (GECAM) is a new powerful instrument to observe TGFs and TEBs, as well as study their properties. For example, it is difficult for most space‐borne high‐energy instruments to distinguish between TGFs and TEBs. However, we show here that, with the joint observation of gamma‐ray and charged particle detectors, GECAM can effectively identify TGFs and TEBs. GECAM can also reveal their fine features in the light curves and spectra.
Key Points
During 9‐month observation, Gravitational‐wave high‐energy Electromagnetic Counterpart All‐sky Monitor (GECAM) has detected 147 bright Terrestrial Gamma‐ray Flashes (TGFs), 2 typical Terrestrial Electron Beams (TEBs), and 2 special TEB‐like events
With novel detector design, GECAM can effectively classify TGFs and TEBs, and reveal their fine temporal features
We obtained a very high TGF‐lightning association rate (∼80%) between GECAM and GLD360 in east Asia region
Objectives
The aim of this study was to investigate the predictive factors for relapse of IgG4‐related disease (IgG4‐RD) and observe the long‐term clinical outcomes in patients with IgG4‐RD.
Methods
...We included in the present analysis 122 patients who were newly diagnosed with IgG4‐RD, treated with glucocorticoid (GC) monotherapy or GC and immunosuppressant combination therapy, and followed for at least 3 years. Clinical relapse, response and side effects were recorded.
Results
The cumulative relapse rates of patients in this study were 10.66%, 22.95% and 27.87% at 12, 24 and 36 months, respectively. Complete drug withdrawal was an independent risk factor for disease relapse. Higher serum IgG4 concentrations, involvement of more organs, higher IgG4 RI scores and elevation of eosinophils at baseline were closely associated with disease relapse. Re‐elevation of serum IgG4 concentrations and low GC maintenance dosage during the follow‐up period were significantly associated with clinical relapse. The GC dosage should be more than 6.25 mg day−1 as monotherapy during the maintenance stage; moreover, combining with immunosuppressants can reduce the GC dosage. Adding GC or immunosuppressants for patients with re‐elevation of serum IgG4 levels could prevent later disease relapse. No serious complications were noted during long‐term follow‐up.
Conclusions
The combination of GC with immunosuppressants was more effective than GC monotherapy during the steroid tapering and maintenance stages. Higher serum IgG4 levels, involvement of more organs, higher IgG4 RI scores, history of allergy, eosinophil elevation at baseline, re‐elevation of serum IgG4 levels and lower GC maintenance dosage at follow‐up might be predictive of relapse.
Polarization is an important property of electromagnetic (EM) wave and different polarization manipulations are required for varied optical applications. Here we report a reconfigurable metasurface ...which achieves both the polarization conversion and the polarization rotation in THz regime. The metasurface is reconfigured through the micro-electro-mechanical-systems (MEMS) actuation. The cross polarization transmittance from a linear polarized incidence is experimentally tuned from 0 to 28% at 2.66 THz. In addition, the polarization rotation angle is effectively changed from -12.8° to 13.1° at 1.78 THz. The tunable bi-functional metasurface for polarization conversion and the polarization rotation can be flexibly applied in various applications such as imaging, polarization microscopy and material analysis, etc.
Graphene oxide (GO) membranes continue to attract intense interest due to their unique molecular sieving properties combined with fast permeation. However, their use is limited to aqueous solutions ...because GO membranes appear impermeable to organic solvents, a phenomenon not yet fully understood. Here, we report efficient and fast filtration of organic solutions through GO laminates containing smooth two-dimensional (2D) capillaries made from large (10-20 μm) flakes. Without modification of sieving characteristics, these membranes can be made exceptionally thin, down to ∼10 nm, which translates into fast water and organic solvent permeation. We attribute organic solvent permeation and sieving properties to randomly distributed pinholes interconnected by short graphene channels with a width of 1 nm. With increasing membrane thickness, organic solvent permeation rates decay exponentially but water continues to permeate quickly, in agreement with previous reports. The potential of ultrathin GO laminates for organic solvent nanofiltration is demonstrated by showing >99.9% rejection of small molecular weight organic dyes dissolved in methanol. Our work significantly expands possibilities for the use of GO membranes in purification and filtration technologies.
The process e+e- → Λ Λ ¯ is studied using data samples at √s = 2.2324, 2.400, 2.800 and 3.080 GeV collected with the BESIII detector operating at the BEPCII collider. The Born cross section is ...measured at √s=2.2324 GeV, which is 1.0 MeV above the Λ Λ ¯ mass threshold, to be 305±$45_{-36}^{+66}$ pb, where the first uncertainty is statistical and the second systematic. The substantial cross section near threshold is significantly larger than that expected from theory, which predicts the cross section to vanish at threshold. The Born cross sections at √s=2.400, 2.800 and 3.080 GeV are measured and found to be consistent with previous experimental results, but with improved precision. Finally, the corresponding effective electromagnetic form factors of Λ are deduced.