In this study, the authors designed checklists to guide care during operating-room crises and evaluated them in a simulated operating room. The availability of checklists improved adherence to best ...practices by operating-room teams during simulations of surgical crises.
Operating-room crises (e.g., massive hemorrhage and cardiac arrest) are high-risk, stressful events that require rapid and coordinated care in a time-critical setting. The reported incidence may be rare for an individual practitioner,
1
but the aggregate incidence for a hospital with 10,000 operations a year is estimated to be approximately 145 such events annually.
2
These are situations in which the way the team cares for a patient will make the difference between life and death. Failure to effectively manage life-threatening complications in surgical patients has been recognized as the largest source of variation in surgical mortality among hospitals.
3
–
7
Small-scale studies . . .
Background Because operating room crises are rare events, failure to adhere to critical management steps is common. We sought to develop and pilot a tool to improve adherence to lifesaving measures ...during operating room crises. Study Design We identified 12 of the most frequently occurring operating room crises and corresponding evidence-based metrics of essential care for each (46 total process measures). We developed checklists for each crisis based on a previously defined method, which included literature review, multidisciplinary expert consultation, and simulation. After development, 2 operating room teams (11 participants) were each exposed to 8 simulations with random assignment to checklist use or working from memory alone. Each team managed 4 simulations with a checklist available and 4 without. One of the primary outcomes measured through video review was failure to adhere to essential processes of care. Participants were surveyed for perceptions of checklist use and realism of the scenarios. Results Checklist use resulted in a 6-fold reduction in failure of adherence to critical steps in management for 8 scenarios with 2 pilot teams. These results held in multivariate analysis accounting for clustering within teams and adjusting for learning or fatigue effects (11 of 46 failures without the checklist vs 2 of 46 failures with the checklist; adjusted relative risk = 0.15, 95% CI, 0.04–0.60; p = 0.007). All participants rated the overall quality of the checklists and scenarios to be higher than average or excellent. Conclusions Checklist use can improve safety and management in operating room crises. These findings warrant broader evaluation, including in clinical settings.
Neurosurgery is a high-risk specialty currently undertaking the pursuit of systematic approaches to measuring and improving outcomes. As part of a project to devise evidence-based safety ...interventions for specialty surgery, the authors sought to review current evidence in cranial tumor resection concerning the frequency of adverse events in practice, their patterns, and current methods of reducing the occurrence of these events. This review represents part of a series of papers written to consolidate information about these events and preventive measures as part of an ongoing effort to ascertain the utility of devising system-wide policies and safety tools to improve neurosurgical practice.
The authors performed a PubMed search using search terms "intracranial neoplasm," "cerebral tumor," "cerebral meningioma," "glioma," and "complications" or "adverse events." Only papers that specifically discussed the relevant complication rates were included. Papers were chosen to maximize the range of rates of occurrence for the reported adverse events.
Review of the tumor neurosurgery literature showed that documented overall complication rates ranged from 9% to 40%, with overall mortality rates of 1.5%-16%. There was a wide range of types of adverse events overall. Deep venous thromboembolism (DVT) was the most common adverse event, with a reported incidence of 3%-26%. The presence of new or worsened neurological deficit was the second most common adverse event found in this review, with reported rates ranging from 0% for the series of meningioma cases with the lowest reported rate to 20% as the highest reported rate for treatment of eloquent glioma. Benign tumor recurrence was found to be a commonly reported adverse event following surgery for intracranial neoplasms. Rates varied depending on tumor type, tumor location, patient demographics, surgical technique, the surgeon's level of experience, degree of specialization, and changes in technology, but these effects remain unmeasured. The incidence on our review ranged from 2% for convexity meningiomas to 36% for basal meningiomas. Other relatively common complications were dural closure-related complications (1%-24%), postoperative peritumoral edema (2%-10%), early postoperative seizure (1%-12%), medical complications (6%-7%), wound infection (0%-4%), surgery-related hematoma (1%-2%), and wrong-site surgery. Strategies to minimize risk of these events were evaluated. Prophylactic techniques for DVT have been widely demonstrated and confirmed, but adherence remains unstudied. The use of image guidance, intraoperative functional mapping, and real-time intraoperative MRI guidance can allow surgeons to maximize resection while preserving neurological function. Whether the extent of resection significantly correlates with improved overall outcomes remains controversial.
A significant proportion of adverse events in intracranial neoplasm surgery may be avoidable by use of practices to encourage use of standardized protocols for DVT, seizure, and infection prophylaxis; intraoperative navigation among other steps; improved teamwork and communication; and concentrated volume and specialization. Systematic efforts to bundle such strategies may significantly improve patient outcomes.
The purpose of this study was to provide an evidence-based algorithm for the design, development, and implementation of a new checklist for the response to an intraoperative neuromonitoring alert ...during spine surgery.
The aviation and surgical literature was surveyed for evidence of successful checklist design, development, and implementation. The limitations of checklists and the barriers to their implementation were reviewed. Based on this review, an algorithm for neurosurgical checklist creation and implementation was developed. Using this algorithm, a multidisciplinary team surveyed the literature for the best practices for how to respond to an intraoperative neuromonitoring alert. All stakeholders then reviewed the evidence and came to consensus regarding items for inclusion in the checklist.
A checklist for responding to an intraoperative neuromonitoring alert was devised. It highlights the specific roles of the anesthesiologist, surgeon, and neuromonitoring personnel and encourages communication between teams. It focuses on the items critical for identifying and correcting reversible causes of neuromonitoring alerts. Following initial design, the checklist draft was reviewed and amended with stakeholder input. The checklist was then evaluated in a small-scale trial and revised based on usability and feasibility.
The authors have developed an evidence-based algorithm for the design, development, and implementation of checklists in neurosurgery and have used this algorithm to devise a checklist for responding to intraoperative neuromonitoring alerts in spine surgery.
As part of a project to devise evidence-based safety interventions for specialty surgery, the authors sought to review current evidence in CSF shunt surgery concerning the frequency of adverse events ...in practice, their patterns, and the state of knowledge regarding methods for their reduction. This review may also inform future and ongoing efforts for the advancement of neurosurgical quality.
The authors performed a PubMed search using search terms "cerebral shunt," "cerebrospinal fluid shunt," "CSF shunt," "ventriculoperitoneal shunt," "cerebral shunt AND complications," "cerebrospinal fluid shunt AND complications," "CSF shunt AND complications," and "ventriculoperitoneal shunt AND complications." Only papers that specifically discussed the relevant complication rates were included. Papers were chosen to be included to maximize the range of rates of occurrence for the adverse events reported.
In this review of the neurosurgery literature, the reported rate of mechanical malfunction ranged from 8% to 64%. The use of programmable valves has increased but remains of unproven benefit even in randomized trials. Infection was the second most common complication, with the rate ranging from 3% to 12% of shunt operations. A meta-analysis that included 17 randomized controlled trials of perioperative antibiotic prophylaxis demonstrated a decrease in shunt infection by half (OR 0.51, 95% CI 0.36-0.73). Similarly, use of detailed protocols including perioperative antibiotics, skin preparation, and limitation of OR personnel and operative time, among other steps, were shown in uncontrolled studies to decrease shunt infection by more than half. Other adverse events included intraabdominal complications, with a reported incidence of 1% to 24%, intracerebral hemorrhage, reported to occur in 4% of cases, and perioperative epilepsy, with a reported association with shunt procedures ranging from 20% to 32%. Potential management strategies are reported but are largely without formal evaluation.
Surgery for CSF shunt placement or revision is associated with a high complication risk due primarily to mechanical issues and infection. Concerted efforts aimed at large-scale monitoring of neurosurgical complications and consistent quality improvement within these highlighted realms may significantly improve patient outcomes.
The surgical Apgar score (SAS) reliably predicts postoperative death and complications and has been validated in a large cohort of general and vascular surgery patients. However, there has been ...limited study of the utility of the score in the neurosurgical population. The authors tested the hypothesis that the SAS would predict postoperative complications and length of stay after neurosurgical procedures.
A cohort of 918 intracranial and spine surgery patients treated over a 3-year period were retrospectively evaluated. The 10-point SAS was calculated and postoperative 30-day mortality and complications rates, intensive care unit (ICU) stay, and hospital stay were assessed by 2 independent raters. Univariate analysis and multivariate logistic regression were performed.
There were 145 patients (15.8%) with at least 1 complication and 24 patients (2.6%) who died within 30 days of surgery. Surgical Apgar scores were significantly associated with the likelihood of postoperative complications (p < 0.001) and death (p = 0.002); scores varied inversely with postoperative complication and mortality risk in a multivariate analysis. Low SASs also predicted prolonged ICU and hospital stay. Patients with scores of 0-2 stayed a mean of 18.9 days (p < 0.001) and patients with scores of 3-4 stayed an average of 14.3 days (p < 0.001) compared with 4.1 days in patients with scores of 9-10.
The application of the surgical Apgar score to a neurosurgical cohort predicted 30-day postoperative mortality and complication rates as well as extended ICU and hospital stay. This readily calculated score may help neurosurgical teams efficiently direct postoperative care to those at highest risk of death and complications.
There are little data on the effects of plated, or plate-only, open-door laminoplasty on cervical range of motion (ROM), neck pain, and clinical outcomes. The purpose of this study was to compare ROM ...after a plated laminoplasty in patients with ossification of posterior longitudinal ligament (OPLL) versus those with cervical spondylotic myelopathy (CSM) and to correlate ROM with postoperative neck pain and neurological outcomes.
The authors retrospectively compared patients with a diagnosis of cervical stenosis due to either OPLL or CSM who had been treated with plated laminoplasty in the period from 2007 to 2012 at the University of California, San Francisco. Clinical outcomes were measured using the modified Japanese Orthopaedic Association (mJOA) scale and neck visual analog scale (VAS). Radiographic outcomes included assessment of changes in the C2-7 Cobb angle at flexion and extension, ROM at C2-7, and ROM of proximal and distal segments adjacent to the plated lamina.
Sixty patients (40 men and 20 women) with an average age of 63.1 ± 10.9 years were included in the study. Forty-one patients had degenerative CSM and 19 patients had OPLL. The mean follow-up period was 20.9 ± 13.1 months. The mean mJOA score significantly improved in both the CSM and the OPLL groups (12.8 to 14.5, p < 0.01; and 13.2 to 14.2, respectively; p = 0.04). In the CSM group, the mean VAS neck score significantly improved from 4.2 to 2.6 after surgery (p = 0.01), but this improvement did not reach the minimum clinically important difference (MCID). Neither was there significant improvement in the VAS neck score in the OPLL group (3.6 to 3.1, p = 0.17). In the CSM group, ROM at C2-7 significantly decreased from 32.7° before surgery to 24.4° after surgery (p < 0.01). In the OPLL group, ROM at C2-7 significantly decreased from 34.4° to 20.8° (p < 0.01). In the CSM group, the change in the VAS neck score significantly correlated with the change in the flexion angle (r = - 0.31) and the extension angle (r = - 0.37); however, it did not correlate with the change in ROM at C2-7 (r = - 0.1). In the OPLL group, the change in the VAS neck score did not correlate with the change in the flexion angle (r = 0.03), the extension angle (r = - 0.17), or the ROM at C2-7 (r = - 0.28). The OPLL group had a significantly greater loss of ROM after surgery than did the CSM group (p = 0.04). There was no significant correlation between the change in ROM and the mJOA score in either group.
Plated laminoplasty in patients with either OPLL or CSM decreases cervical ROM, especially in the extension angle. Among patients who have undergone laminoplasty, those with OPLL lose more ROM than do those with CSM. No correlation was observed between neck pain and ROM in either group. Neither group had a change in neck pain that reached the MCID following laminoplasty. Both groups improved in neurological function and outcomes.
Cervical kyphosis can lead to spinal instability, spinal cord injury, and disability. The correction of cervical kyphosis is technically challenging, especially in severe cases. The authors describe ...the anterior sequential interbody dilation technique for the treatment of cervical kyphosis and evaluate perioperative outcomes, degree of correction, and long-term follow-up outcomes associated with the technique.
In the period from 2006 to 2011, a consecutive cohort of adults with cervical kyphosis (Cobb angles ≥ 0°) underwent sequential interbody dilation, a technique entailing incrementally increased interbody distraction with the sequential placement of larger spacers (at least 1 mm) in the discectomy and/or corpectomy spaces. The authors retrospectively reviewed these patients, and primary outcomes of interest included kyphosis correction, blood loss, hospital stay, complications, Nurick grade, pain, reoperation, and pseudarthrosis. A subgroup analysis among patients with preoperative kyphosis of 0°-9° (mild), 10°-19° (moderate), and ≥ 20° (severe) was performed.
One hundred patients were included in the study: 74 with mild preoperative cervical kyphosis, 19 with moderate, and 7 with severe. The mean patient age was 53.1 years, and 54.0% of the patients were male. Mean estimated blood loss was 305.6 ml, and the mean length of hospital stay was 5.2 days. The overall complication rate was 9.0%, and there were no deaths. Sixteen percent of patients underwent supplemental posterior fusion. There was significant correction in cervical alignment (p < 0.001), and the mean overall kyphosis correction was 12.4°. Patients with severe preoperative kyphosis gained a correction of 24.7°, those with moderate kyphosis gained 17.8°, and those with mild kyphosis gained 10.1°. A mean correction of 32.0° was obtained if 5 levels were addressed. The mean follow-up was 26.8 months. The reoperation rate was 4.7%. At follow-up, there was significant improvement in visual analog scale neck pain (p = 0.020) and Nurick grade (p = 0.037). The pseudarthrosis rate was 6.3%.
Sequential interbody dilation is a feasible and effective method of correcting cervical kyphosis. Complications and reoperation rates are low. Similar benefits are seen among all severities of kyphosis, and greater correction can be achieved in more severe cases.
As part of a project to devise evidence-based safety interventions for specialty surgery, we sought to review current evidence concerning the frequency of adverse events in open cerebrovascular ...neurosurgery and the state of knowledge regarding methods for their reduction. This review represents part of a series of papers written to consolidate information about these events and preventive measures as part of an ongoing effort to ascertain the utility of devising system-wide policies and safety tools to improve neurosurgical practice.
The authors performed a PubMed search using search terms "cerebral aneurysm", "cerebral arteriovenous malformation", "intracerebral hemorrhage", "intracranial hemorrhage", "subarachnoid hemorrhage", and "complications" or "adverse events." Only papers that specifically discussed the relevant complication rates were included. Papers were chosen to be included to maximize the range of rates of occurrence for the reported adverse events.
The review revealed hemorrhage-related hyperglycemia (incidence rates ranging from 27% to 71%) and cerebral salt-wasting syndromes (34%-57%) to be the most common perioperative adverse events related to subarachnoid hemorrhage (SAH). Next in terms of frequency was new cerebral infarction associated with SAH, with a rate estimated at 40%. Many techniques are advocated for use during surgery to minimize risk of this development, including intraoperative neurophysiological monitoring, but are not universally used due to surgeon preference and variable availability of appropriate staffing and equipment. The comparative effectiveness of using or omitting monitoring technologies has not been evaluated. The incidence of perioperative seizure related to vascular neurosurgery is unknown, but reported seizure rates from observational studies range from 4% to 42%. There are no standard guidelines for the use of seizure prophylaxis in these patients, and there remains a need for prospective studies to support such guidelines. Intraoperative rupture occurs at a rate of 7% to 35% and depends on aneurysm location and morphology, history of rupture, surgical technique, and surgeon experience. Preventive strategies include temporary vascular clipping. Technical adverse events directly involving application of the aneurysm clip include incomplete aneurysm obliteration and parent vessel occlusion. The rates of these events range from 5% to 18% for incomplete obliteration and 3% to 12% for major vessel occlusion. Intraoperative angiography is widely used to confirm clip placement; adjuncts include indocyanine green video angiography and microvascular Doppler ultrasonography. Use of these technologies varies by institution.
A significant proportion of these complications may be avoidable through development and testing of standardized protocols to incorporate monitoring technologies and specific technical practices, teamwork and communication, and concentrated volume and specialization. Collaborative monitoring and evaluation of such protocols are likely necessary for the advancement of open cerebrovascular neurosurgical quality.
Adverse events are common in neurosurgery. Their reporting is inconsistent and widely variable due to nonuniform definitions, data collection mechanisms, and retrospective data collection. ...Historically, neurosurgery has lagged behind general and cardiac surgical fields in the creation of multi-institutional prospective databases allowing for benchmarking and accurate adverse event/outcomes measurement, the bedrock of evidence used to guide quality improvement initiatives. The National Neurosurgery Quality and Outcomes Database has begun to address this issue by collecting prospective, multi-institutional outcomes data in neurosurgical patients. Once reliable outcomes exist, various targeted quality improvement strategies may be used to reduce adverse events and improve outcomes.