To report outcomes across three countries for patients with symptomatic knee or hip OA attending the evidence-based education and exercise therapy program Good Life with osteoArthritis from Denmark ...(GLA:D®).
GLA:D® is a structured treatment program including 2–3 patient education sessions and 12 supervised exercise sessions delivered over 8 weeks by certified health care practitioners. The program was introduced in Denmark in 2013, in Canada 2015 and in Australia 2016. Absolute mean change in pain intensity, number of chair stands in 30 s, 40 m walk test time and Knee injury and Osteoarthritis Outcome Score (KOOS)/Hip dysfunction and Osteoarthritis Outcome Score (HOOS) QOL subscale scores from baseline to immediately after treatment were reported as means and 95 % CIs and proportion of responders for each country.
Patients from the three countries improved 26–33% in mean pain intensity, 8–12% in walking speed, 18–30% in chair stand ability and 12–26% in joint-related quality of life from baseline to immediately after treatment, with no clinically relevant differences between patients with hip and knee OA. These improvements correspond with moderate to large within-group effect sizes and 43–47 % of the patients experienced clinically relevant pain reductions.
About half or more of patients across the three countries were categorized as responders for pain and objective function following the implementation of GLA:D®. These findings indicate positive patient outcomes associated with GLA:D® participation across varying health care systems from implementation of guideline-based patient education and exercise therapy for knee and hip OA.
Chronic Opioid Use Prior to Total Knee Arthroplasty Zywiel, Michael G., MD; Stroh, D. Alex, BS; Mont, Michael A., MD ...
Journal of bone and joint surgery. American volume,
2011-November-2, Letnik:
93, Številka:
21
Journal Article
Recenzirano
Background Chronic use of opioid medications may lead to dependence or hyperalgesia, both of which might adversely affect perioperative and postoperative pain management, rehabilitation, and clinical ...outcomes after total knee arthroplasty. The purpose of this study was to evaluate patients who underwent total knee arthroplasty following six or more weeks of chronic opioid use for pain control and to compare them with a matched group who did not use opioids preoperatively. Methods Forty-nine knees in patients who had a mean age of fifty-six years (range, thirty-seven to seventy-eight years) and who had regularly used opioid medications for pain control prior to total knee arthroplasty were compared with a group of patients who had not used them. Length of hospitalization, aseptic complications requiring reoperation, requirement for specialized pain management, and clinical outcomes were assessed for both groups. Results Knee Society scores were significantly lower in the patients who regularly used opioid medications at the time of final follow-up (mean, three years; range, two to seven years); the opioid group had a mean of 79 points (range, 45 to 100 points) as compared with a mean of 92 points (range, 59 to 100 points) in the non-opioid group. A significantly higher prevalence of complications was seen in the opioid group, with five arthroscopic evaluations and eight revisions for persistent stiffness and/or pain, compared with none in the matched group. Ten patients in the opioid group were referred for outpatient pain management, compared with one patient in the non-opioid group. Conclusions Patients who chronically use opioid medications prior to total knee arthroplasty may be at a substantially greater risk for complications and painful prolonged recoveries. Alternative non-opioid pain medications and/or earlier referral to an orthopaedic surgeon prior to habitual opioid use should be considered for patients with painful degenerative disease of the knee. Level of Evidence Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Symptomatic cobalt toxicity from a failed total hip replacement is a rare but devastating complication. It has been reported following revision of fractured ceramic components, as well as in patients ...with failed metal-on-metal articulations. Potential clinical findings include fatigue, weakness, hypothyroidism, cardiomyopathy, polycythaemia, visual and hearing impairment, cognitive dysfunction, and neuropathy. We report a case of an otherwise healthy 46-year-old patient, who developed progressively worsening symptoms of cobalt toxicity beginning approximately six months following synovectomy and revision of a fractured ceramic-on-ceramic total hip replacement to a metal-on-polyethylene bearing. The whole blood cobalt levels peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy. Implant retrieval analysis confirmed a loss of 28.3 g mass of the cobalt-chromium femoral head as a result of severe abrasive wear by ceramic particles embedded in the revision polyethylene liner. Autopsy findings were consistent with heavy metal-induced cardiomyopathy.We recommend using new ceramics at revision to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components.
Recently, the use of metal-on-metal articulations in total hip arthroplasty (THA) has led to an increase in adverse events owing to local soft-tissue reactions from metal ions and wear debris. While ...the majority of these implants perform well, it has been increasingly recognised that a small proportion of patients may develop complications secondary to systemic cobalt toxicity when these implants fail. However, distinguishing true toxicity from benign elevations in cobalt ion levels can be challenging. The purpose of this two part series is to review the use of cobalt alloys in THA and to highlight the following related topics of interest: mechanisms of cobalt ion release and their measurement, definitions of pathological cobalt ion levels, and the pathophysiology, risk factors and treatment of cobalt toxicity. Historically, these metal-on-metal arthroplasties are composed of a chromium-cobalt articulation. The release of cobalt is due to the mechanical and oxidative stresses placed on the prosthetic joint. It exerts its pathological effects through direct cellular toxicity. This manuscript will highlight the pathophysiology of cobalt toxicity in patients with metal-on-metal hip arthroplasties.
Patients with new or evolving hip symptoms with a prior history of THA warrant orthopaedic surgical evaluation. Increased awareness of the range of systemic symptoms associated with cobalt toxicity, coupled with prompt orthopaedic intervention, may forestall the development of further complications.
As adverse events related to metal on metal hip arthroplasty have been better understood, there has been increased interest in toxicity related to the high circulating levels of cobalt ions. However, ...distinguishing true toxicity from benign elevations in cobalt levels can be challenging. The purpose of this review is to examine the use of cobalt alloys in total hip arthroplasty, to review the methods of measuring circulating cobalt levels, to define a level of cobalt which is considered pathological and to review the pathophysiology, risk factors and treatment of cobalt toxicity. To the best of our knowledge, there are 18 published cases where cobalt metal ion toxicity has been attributed to the use of cobalt-chromium alloys in hip arthroplasty. Of these cases, the great majority reported systemic toxic reactions at serum cobalt levels more than 100 μg/L. This review highlights some of the clinical features of cobalt toxicity, with the goal that early awareness may decrease the risk factors for the development of cobalt toxicity and/or reduce its severity.
Severe adverse events can arise from the release of cobalt from metal-on-metal arthroplasties, and as such, orthopaedic surgeons should not only be aware of the presenting problems, but also have the knowledge to treat appropriately.
The aim of this review is to address controversies in the management of dislocations of the acromioclavicular joint. Current evidence suggests that operative rather than non-operative treatment of ...Rockwood grade III dislocations results in better cosmetic and radiological results, similar functional outcomes and longer time off work. Early surgery results in better functional and radiological outcomes with a reduced risk of infection and loss of reduction compared with delayed surgery. Surgical options include acromioclavicular fixation, coracoclavicular fixation and coracoclavicular ligament reconstruction. Although non-controlled studies report promising results for arthroscopic coracoclavicular fixation, there are no comparative studies with open techniques to draw conclusions about the best surgical approach. Non-rigid coracoclavicular fixation with tendon graft or synthetic materials, or rigid acromioclavicular fixation with a hook plate, is preferable to fixation with coracoclavicular screws owing to significant risks of loosening and breakage. The evidence, although limited, also suggests that anatomical ligament reconstruction with autograft or certain synthetic grafts may have better outcomes than non-anatomical transfer of the coracoacromial ligament. It has been suggested that this is due to better restoration horizontal and vertical stability of the joint. Despite the large number of recently published studies, there remains a lack of high-quality evidence, making it difficult to draw firm conclusions regarding these controversial issues.
Abstract The purpose of this study was to evaluate effectiveness of an advance, at-home chlorhexidine-impregnated skin preparation cloth in decreasing the incidence of deep periprosthetic hip ...arthroplasty infections. Arthroplasty surgeons at the senior author's institution provided their patients with chlorhexidine-impregnated single-use cloths for use at home the night before and the morning of surgery. Between January 2007 and December 2009, the compliance of this practice, as well as the incidence of periprosthetic infections, was monitored for all patients who underwent hip arthroplasty. Of the 1134 patients who underwent hip arthroplasty, 157 patients completely complied with the preoperative chlorhexidine preparation protocol. There were 14 infections in the group that was not compliant (1.6% infection rate), and there were no infections in the compliant patient population. Based on the results of this study, at-home preoperative patient skin preparation appears to be a simple and cost-effective method to reduce periprosthetic hip infection rates.
Many techniques and technologies exist for the intraoperative assessment of component positioning, leg lengths, and offset in total hip arthroplasty, but with limited comparative data. We conducted a ...systematic review of the available literature to evaluate the range of techniques and technologies for the intraoperative assessment of component position as well as leg lengths and offset in terms of accuracy, precision, surgical time, cost, and relationship to clinical outcomes.
A comprehensive search of the Embase and Medline databases from 1974 to 2023 was performed. We included controlled or comparative prospective clinical studies. Cochrane’s risk-of-bias tool for randomized trials and Risk of Bias in Non-Randomized Studies – of Interventions tools were used by 2 independent reviewers to evaluate each study for risk of bias. We conducted both qualitative and quantitative analyses of the studies included. However, a meta-analysis was deemed not to be feasible due to heterogeneity.
Our review included 25 studies with 52 intraoperative techniques and technologies. Mechanical guides and computerized navigation were most frequently evaluated in the included studies. Computerized navigation systems consistently showed the greatest accuracy and precision across all measures, at the cost of longer mean operative time. In contrast, freehand techniques demonstrated the poorest accuracy and precision. Insufficient data were found to reach any meaningful conclusions in terms of differences in overall surgical cost or clinical outcomes.
Evidence shows that computerized navigation systems are most accurate and precise in positioning components during total hip arthroplasty. Further research is needed to determine their health and economic impact and whether the accuracy and precision of navigated techniques are justified in terms of clinical outcomes.
Hip Pain and Heart Failure: The Missing Link Gilbert, Cameron J., MD; Cheung, Angela, MD; Butany, Jagdish, MD ...
Canadian journal of cardiology,
05/2013, Letnik:
29, Številka:
5
Journal Article
Recenzirano
Abstract A man presented with hypothyroidism, dilated cardiomyopathy, a pericardial effusion, liver failure, and polycythaemia. He had a history of bilateral hip replacements and new-onset hip pain. ...The patient progressed to develop shock. Given his acutely profound illness and constellation of symptoms, as well as the history of hip replacement, a diagnosis of cobalt toxicity was made.
Down's syndrome is associated with a number of musculoskeletal abnormalities, some of which predispose patients to early symptomatic arthritis of the hip. The purpose of the present study was to ...review the general and hip-specific factors potentially compromising total hip replacement (THR) in patients with Down's syndrome, as well as to summarise both the surgical techniques that may anticipate the potential adverse impact of these factors and the clinical results reported to date. A search of the literature was performed, and the findings further informed by the authors' clinical experience, as well as that of the hip replacement in Down Syndrome study group. The general factors identified include a high incidence of ligamentous laxity, as well as associated muscle hypotonia and gait abnormalities. Hip-specific factors include: a high incidence of hip dysplasia, as well as a number of other acetabular, femoral and combined femoroacetabular anatomical variations. Four studies encompassing 42 hips, which reported the clinical outcomes of THR in patients with Down's syndrome, were identified. All patients were successfully treated with standard acetabular and femoral components. The use of supplementary acetabular screw fixation to enhance component stability was frequently reported. The use of constrained liners to treat intra-operative instability occurred in eight hips. Survival rates of between 81% and 100% at a mean follow-up of 105 months (6 to 292) are encouraging. Overall, while THR in patients with Down's syndrome does present some unique challenges, the overall clinical results are good, providing these patients with reliable pain relief and good function.