In the early stage esophageal cancer, changes in the mucosa are subtle and pass unnoticed in endoscopic examinations using white light. To increase sensitivity, chromoscopy with Lugol's solution has ...been used. Technological advancements have led to the emergence of virtual methods of endoscopic chromoscopy, including narrow band imaging (NBI). NBI enhances the relief of the mucosa and the underlying vascular pattern, providing greater convenience without the risks inherent to the use of vital dye. The purpose of this systematic review and meta-analysis was to evaluate the ability of NBI to diagnose squamous cell carcinoma of the esophagus and to compare it to chromoscopy with Lugol's solution.
This systematic review included all studies comparing the diagnostic accuracy of NBI and Lugol chromoendoscopy performed to identify high-grade dysplasia and/or squamous cell carcinoma in the esophagus. In the meta-analysis, we calculated and demonstrated sensitivity, specificity, and positive and negative likelihood values in forest plots. We also determined summary receiver operating characteristic (sROC) curves and estimates of the areas under the curves for both per-patient and per-lesion analysis.
The initial search identified 7079 articles. Of these, 18 studies were included in the systematic review and 12 were used in the meta-analysis, for a total of 1911 patients. In per-patient and per-lesion analysis, the sensitivity, specificity, and positive and negative likelihood values for Lugol chromoendoscopy were 92% and 98, 82 and 37%, 5.42 and 1.4, and 0.13 and 0.39, respectively, and for NBI were 88 and 94%, 88 and 65%, 8.32 and 2.62, and 0.16 and 0.12, respectively. There was a statistically significant difference in only specificity values, in which case NBI was superior to Lugol chromoendoscopy in both analyses. In the per-patient analysis, the area under the sROC curve for Lugol chromoendoscopy was 0.9559. In the case of NBI, this value was 0.9611; in the per-lesion analysis, this number was 0.9685 and 0.9587, respectively.
NBI was adequate in evaluating the esophagus in order to diagnose high-grade dysplasia and squamous cell carcinoma. In the differentiation of those disorders from other esophageal mucosa alterations, the NBI was shown to be superior than Lugol.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Semaglutide is a long-acting glucagon-like peptide-1 receptor agonist used for management of type 2 diabetes and/or obesity. To test the hypothesis that perioperative semaglutide use is associated ...with delayed gastric emptying and increased residual gastric content (RGC) despite adequate preoperative fasting, we compared the RGC of patients who had and had not taken semaglutide prior to elective esophagogastroduodenoscopy. The primary outcome was the presence of increased RGC.
Single-center retrospective electronic chart review.
Tertiary hospital.
Patients undergoing esophagogastroduodenoscopy under deep sedation/general anesthesia between July/2021–March/2022.
Patients were divided into two (SG = semaglutide, NSG = non-semaglutide) groups, according to whether they had received semaglutide within 30 days prior to the esophagogastroduodenoscopy.
Increased RGC was defined as any amount of solid content, or > 0.8 mL/Kg (measured from the aspiration/suction canister) of fluid content.
Of the 886 esophagogastroduodenoscopies performed, 404 (33 in the SG and 371 in the NSG) were included in the final analysis. Increased RGC was observed in 27 (6.7%) patients, being 8 (24.2%) in the SG and 19 (5.1%) in the NSG (p < 0.001). Semaglutide use 5.15 (95%CI 1.92–12.92) and the presence of preoperative digestive symptoms (nausea/vomiting, dyspepsia, abdominal distension) 3.56 (95%CI 2.2–5.78) were associated with increased RGC in the propensity weighted analysis. Conversely, a protective 0.25 (95%CI 0.16–0.39) effect against increased RGC was observed in patients undergoing esophagogastroduodenoscopy combined with colonoscopy. In the SG, the mean time of preoperative semaglutide interruption in patients with and without increased RGC was 10.5 ± 5.5 and 10.2 ± 5.6 days, respectively (p = 0.54). There was no relationship between semaglutide use and the amount/volume of RGC found on esophagogastroduodenoscopy (p = 0.99). Only one case (in the SG) of pulmonary aspiration was reported.
Semaglutide was associated with increased RGC in patients undergoing elective esophagogastroduodenoscopy. Digestive symptoms prior to esophagogastroduodenoscopy were also predictive of increased RGC.
•Semaglutide, a GLP-1 agonist, has been associated with delayed gastric emptying.•5.1% of patients not using semaglutide had increased residual gastric content (RGC).•24.2% of patients taking semaglutide perioperatively had increased RGC (p < 0.001).•Presence of pre-endoscopy digestive symptoms was also associated with increased RGC.•Interval of preoperative semaglutide cessation was not predictive of increased RGC.
Post-surgical leaks and fistulas are the most feared complication of bariatric surgery. They have become more common in clinical practice given the increasing number of these procedures and can be ...very difficult to treat. These two related conditions must be distinguished and characterized to guide the appropriate treatment. Leak is defined as a transmural defect with communication between the intra and extraluminal compartments, while fistula is defined as an abnormal communication between two epithelialized surfaces. Traditionally, surgical treatment was the preferred approach for leaks and fistulas and was associated with high morbidity with significant mortality rates. However, with the development of novel devices and techniques, endoscopic therapy plays an increasingly essential role in managing these conditions. Early diagnosis and endoscopic therapy initiation after clinical stabilization are crucial to success since clinical success rates are higher for acute leaks and fistulas when compared to late and chronic leaks and fistulas. Several endoscopic techniques are available with different mechanisms of action, including direct closure, covering/diverting or draining. The treatment should be individualized by considering the characteristics of both the patient and the defect. Although there is a lack of high-quality studies to provide standardized treatment algorithms, this narrative review aims to provide a summary of the current scientific evidence and, based on this data and our extensive experience, make recommendations to help choose the best endoscopic approach for the management of post-bariatric surgical leaks and fistulas.
To compare the complications and mortality related to gastrostomy procedures performed using surgical and percutaneous endoscopic gastrostomy techniques, this review covered seven studies. Five of ...these were retrospective and two were randomized prospective studies. In total, 406 patients were involved, 232 of whom had undergone percutaneous endoscopic gastrostomy and 174 of whom had undergone surgical gastrostomy. The analysis was performed using Review Manager. Risk differences were computed using a fixed-effects model and forest and funnel plots. Data on risk differences and 95% confidence intervals were obtained using the Mantel-Haenszel test. There was no difference in major complications in retrospective (95% CI (-0.11 to 0.10)) or randomized (95% CI (-0.07 to 0.05)) studies. Regarding minor complications, no difference was found in retrospective studies (95% CI (-00.17 to 0.09)), whereas a difference was observed in randomized studies (95% CI (-0.25 to -0.02)). Separate analyses of retrospective and randomized studies revealed no differences between the methods in relation to mortality and major complications. Moreover, low levels of minor complications were observed among endoscopic procedures in randomized studies, with no difference observed compared with retrospective studies.
Our aim in this study was to compare the efficiency of 25G versus 22G needles in diagnosing solid pancreatic lesions by EUS-FNA. We performed a systematic review and meta-analysis. Studies were ...identified in five databases using an extensive search strategy. Only randomized trials comparing 22G and 25G needles were included. The results were analyzed by fixed and random effects. A total of 504 studies were found in the search, among which 4 randomized studies were selected for inclusion in the analysis. A total of 462 patients were evaluated (233: 25G needle/229: 22G needle). The diagnostic sensitivity was 93% for the 25G needle and 91% for the 22G needle. The specificity of the 25G needle was 87%, and that of the 22G needle was 83%. The positive likelihood ratio was 4.57 for the 25G needle and 4.26 for the 22G needle. The area under the sROC curve for the 25G needle was 0.9705, and it was 0.9795 for the 22G needle, with no statistically significant difference between them (p=0.497). Based on randomized studies, this meta-analysis did not demonstrate a significant difference between the 22G and 25G needles used during EUS-FNA in the diagnosis of solid pancreatic lesions.
Background and Aims: There are no systematic reviews comparing the use of endoscopic retrograde cholangiopancreatography (ERCP)-based brush cytology and forceps biopsy and endoscopic ultrasound ...(EUS)-guided fine-needle aspiration (FNA) for the diagnosis of malignant biliary stricture; so in this revision, we will compare ERCP against EUS-FNA for tissue diagnosis of malignant biliary stricture. Design: A systematic review was conducted of comparative studies (prospective or retrospective) analyzing EUS and ERCP for tissue diagnosis of malignant biliary stricture. Materials and Methods: The databases Medline, EMBASE, Cochrane, LILACS, CINAHL, and Scopus were searched for studies dated previous to November 2014. We identified three prospective studies comparing EUS-FNA and ERCP for the diagnosis of malignant biliary stricture and five prospective studies comparing EUS-FNA with the same diagnosis of the other three studies. All patients were subjected to the same gold standard method. We calculated study variables (sensitivity, specificity, prevalence, positive and negative predictive values, and accuracy) and performed a meta-analysis using the Review Manager (RevMan) 5.3 software. Results: A total of 294 patients were included in the analysis. The pretest probability for malignant biliary stricture was 76.66%. The mean sensitivities of ERCP and EUS-FNA for tissue diagnosis of malignant biliary stricture were 49% and 75%, respectively; the specificities were 96.33% and 100%, respectively. The posttest probabilities positive predictive value (98.33% and 100%, respectively) and negative predictive value (34% and 47%, respectively) were determined. The accuracies were 60.66% and 79%, respectively. Conclusion: We found that EUS-FNA was superior to ERCP with brush cytology and forceps biopsy for diagnosing malignant biliary strictures. However, a negative EUS-FNA or ERCP test may not exclude malignant biliary stricture because both have low negative posttest probabilities.
Intragastric balloon (IGB) is a minimally invasive and reversible therapy for weight loss with a good efficacy and safety profile. Introduced in the 1980s, IGBs have significantly evolved in the last ...couple of decades. They mechanically act by decreasing the volume of the stomach and its reservoir capacity, delaying gastric emptying, and increasing satiety leading to a subsequent weight loss. Despite the low rates of complications and mortality associated with IGBs, adverse events and complications still occur and can range from mild to fatal. This review aims to provide an update on the current scientific evidence in regard to complications and adverse effects of the use of the IGB and its treatment. This is the first comprehensive narrative review in the literature dedicated to this subject.
Graphical abstract
A gastrointestinal (GI) transmural defect is defined as total rupture of the GI wall, and these defects can be divided into three categories: perforations, leaks, and fistulas. Surgical management of ...these defects is usually challenging and may be associated with high morbidity and mortality rates. Recently, several novel endoscopic techniques have been developed, and endoscopy has become a first-line approach for therapy of these conditions. The use of endoscopic vacuum therapy (EVT) is increasing with favorable results. This technique involves endoscopic placement of a sponge connected to a nasogastric tube into the defect cavity or lumen. This promotes healing
five mechanisms, including macrodeformation, microdeformation, changes in perfusion, exudate control, and bacterial clearance, which is similar to the mechanisms in which skin wounds are treated with commonly employed wound vacuums. EVT can be used in the upper GI tract, small bowel, biliopancreatic regions, and lower GI tract, with variable success rates and a satisfactory safety profile. In this article, we review and discuss the mechanism of action, materials, techniques, efficacy, and safety of EVT in the management of patients with GI transmural defects.
Serologic testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) promises to assist in assessing exposure to and confirming the diagnosis of coronavirus disease 2019 (COVID-19), and ...to provide a roadmap for reopening countries worldwide. Considering this, a proper understanding of serologic-based diagnostic testing characteristics is critical. The aim of this study was to perform a structured systematic review and meta-analysis to evaluate the diagnostic characteristics of serological-based COVID-19 testing. Electronic searches were performed using Medline (PubMed), EMBASE, and Cochrane Library. Full-text observational studies that reported IgG or IgM diagnostic yield and used nucleic acid amplification tests (NAATs) of respiratory tract specimens, as a the reference standard in English language were included. A bivariate model was used to compute pooled sensitivity, specificity, positive/negative likelihood ratio (LR), diagnostic odds ratio (OR), and summary receiver operating characteristic curve (SROC) with corresponding 95% confidence intervals (CIs). Five studies (n=1,166 individual tests) met inclusion criteria. The pooled sensitivity, specificity, and diagnostic accuracy for IgG was 81% (95% CI, 61-92);I2=95.28, 97% (95% CI, 78-100);I2=97.80, and 93% (95% CI, 91-95), respectively. The sensitivity, specificity, and accuracy for IgM antibodies was 80% (95% CI, 57-92);I2=94.63, 96% (95% CI, 81-99);I2=92.96 and 95% (95% CI, 92-96). This meta-analysis demonstrates suboptimal sensitivity and specificity of serologic-based diagnostic testing for SARS-CoV-2 and suggests that antibody testing alone, in its current form, is unlikely to be an adequate solution to the difficulties posed by COVID-19 and in guiding future policy decisions regarding social distancing and reopening of the economy worldwide.
Adverse events (AEs) after ERCP are not uncommon and post-ERCP acute pancreatitis (PEP) is the most important one. Thermal injury from biliary sphincterotomy may play an important role and trigger ...PEP or bleeding. Therefore, this study evaluates the outcomes of two electric current modes used during biliary sphincterotomy.
From October 2019 to August 2021, consecutive native papilla patients undergoing ERCP with biliary sphincterotomy were randomized to either the pure cut or endocut after cannulation. The primary outcome was PEP incidence. Secondary outcomes included intraprocedural and delayed bleeding, infection, and perforation.
550 patients were randomized (272 Pure cut, 278 Endocut). The overall PEP rate was 4.0% and significantly higher in the Endocut group (5.8% vs/ 2.2%, p=0.034). Univariate analysis revealed >5 attempts (p=0.004) and Endocut mode (p=0.034) as risk factors for PEP. Multivariate analysis revealed >5 attempts (p=0.005) and a trend for Endocut mode as a risk factor for PEP (p=0.052). Intraprocedural bleeding occurred more often with Pure cut (p=0.018), but all cases were controlled endoscopically during the ERCP. Delayed bleeding was more frequent with Endocut (p=0.047). There was no difference in terms of perforation (p=1.0) or infection (p=0.4999) between the groups.
Endocut mode may increase thermal injury leading to higher rates of PEP and delayed bleeding, whereas Pure cut is associated with increased intraprocedural bleeding without clinical repercussion. The electric current mode is not related to perforation or infection. Further RCTs assessing the impact of electric current on AEs with overlapping preventive measures such as rectal NSAIDs and hyperhydration are needed.The study was submitted to the Brazilian Clinical Trials Platform (http://www.ensaiosclinicos.gov.br) under the registry number RBR-5d27tn.