This review evaluates the reliability and validity of ultrasound to quantify muscles in older adults. The databases PubMed, Cochrane, and Cumulative Index to Nursing and Allied Health Literature were ...systematically searched for studies. In 17 studies, the reliability (n = 13) and validity (n = 8) of ultrasound to quantify muscles in community‐dwelling older adults (≥60 years) or a clinical population were evaluated. Four out of 13 reliability studies investigated both intra‐rater and inter‐rater reliability. Intraclass correlation coefficient (ICC) scores for reliability ranged from −0.26 to 1.00. The highest ICC scores were found for the vastus lateralis, rectus femoris, upper arm anterior, and the trunk (ICC = 0.72 to 1.000). All included validity studies found ICC scores ranging from 0.92 to 0.999. Two studies describing the validity of ultrasound to predict lean body mass showed good validity as compared with dual‐energy X‐ray absorptiometry (r2 = 0.92 to 0.96). This systematic review shows that ultrasound is a reliable and valid tool for the assessment of muscle size in older adults. More high‐quality research is required to confirm these findings in both clinical and healthy populations. Furthermore, ultrasound assessment of small muscles needs further evaluation. Ultrasound to predict lean body mass is feasible; however, future research is required to validate prediction equations in older adults with varying function and health.
Sufficient physical activity is important for solid organ transplant recipients (heart, lung, liver, kidney). However, recipients do not meet the recommended amount or required type of physical ...activity. The perceived barriers to and facilitators of physical activity in this population are largely unknown.
Semi-structured in depth interviews were conducted with solid organ transplant recipients in order to explore experienced barriers and facilitators. Qualitative methodology with thematic line-by-line analysis was used for analysis, and derived themes were classified into personal and environmental factors.
The most important indicated barriers were physical limitations, insufficient energy level, fear, and comorbidities. The most frequently mentioned facilitators included motivation, coping, consequences of (in)activity, routine/habit, goals/goal priority, and responsibility for the transplanted organ. Neutral factors acting as a barrier or facilitator were self-efficacy and expertise of personnel. A comparison of barriers and facilitators between transplant recipient groups yielded no overt differences.
Several personal and environmental factors were indicated that should be considered in intervention development to increase physical activity behavior in solid organ transplant recipients.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
PURPOSETo examine the test–retest reliability and validity of ten activity trackers for step counting at three different walking speeds.
METHODSThirty-one healthy participants walked twice on a ...treadmill for 30 min while wearing 10 activity trackers (Polar Loop, Garmin Vivosmart, Fitbit Charge HR, Apple Watch Sport, Pebble Smartwatch, Samsung Gear S, Misfit Flash, Jawbone Up Move, Flyfit, and Moves). Participants walked three walking speeds for 10 min each; slow (3.2 km·h), average (4.8 km·h), and vigorous (6.4 km·h). To measure test–retest reliability, intraclass correlations (ICC) were determined between the first and second treadmill test. Validity was determined by comparing the trackers with the gold standard (hand counting), using mean differences, mean absolute percentage errors, and ICC. Statistical differences were calculated by paired-sample t tests, Wilcoxon signed-rank tests, and by constructing Bland–Altman plots.
RESULTSTest–retest reliability varied with ICC ranging from −0.02 to 0.97. Validity varied between trackers and different walking speeds with mean differences between the gold standard and activity trackers ranging from 0.0 to 26.4%. Most trackers showed relatively low ICC and broad limits of agreement of the Bland–Altman plots at the different speeds. For the slow walking speed, the Garmin Vivosmart and Fitbit Charge HR showed the most accurate results. The Garmin Vivosmart and Apple Watch Sport demonstrated the best accuracy at an average walking speed. For vigorous walking, the Apple Watch Sport, Pebble Smartwatch, and Samsung Gear S exhibited the most accurate results.
CONCLUSIONTest–retest reliability and validity of activity trackers depends on walking speed. In general, consumer activity trackers perform better at an average and vigorous walking speed than at a slower walking speed.
Introduction
Positive attitudes towards family involvement in nursing care are essential for improving the involvement of and collaboration with patients’ families. The aim of this study is to ...explore nurses’ attitudes towards the importance of families in nursing care.
Method
Using a cross‐sectional design, hospital and homecare nurses completed the Families Importance to Nursing Care (FINC‐NA) scale, Dutch language version, consisting of four subscales. Data were analysed using descriptive statistics and regression analyses.
Results
A total of 426 hospital and homecare nurses were eligible for analysis (mean (SD) age 42 years (13), 93% female). The mean (SD) attitude of nurses was 63.8 (12) (100‐point scale) on the FINC‐NA. Less than half of the nurses (44%) considered family as a collaboration partner, and 37% of nurses stated that families should be invited to actively participate in planning patient care. The nurses’ attitudes were explained by years of work experience in nursing, work setting and existing policy regarding families in patient care.
Conclusion
This study identifies areas of improvement regarding to nurses’ attitudes towards the importance of families in nursing care in order to establish a more family‐focused approach in nursing care. Nursing policies should facilitate working with families as part of regular nursing processes. Furthermore, the importance of family involvement in care should be an explicit matter of concern for nursing educational institutions and for policy making within healthcare organisations.
Background
For families with adolescent children, the transition to adulthood is usually challenging. This period may be extra demanding for families with a child with profound intellectual and ...multiple disabilities due to the child's strong and persistent support needs. To support these families during this phase and to facilitate the transition process of these adolescents, we adapted the Canadian skills for growing up (SGU) into the skills for growing up‐profound intellectual and multiple disabilities (SGU‐PIMD). The aim of this study is to determine its content validity.
Method
A Delphi study with family members and healthcare professionals was conducted.
Results
Results showed good content validity. However, the Delphi panel suggested minor adjustments to improve relevance, comprehensibility and comprehensiveness.
Conclusions
The current SGU‐PIMD can be used in practice for supporting adolescents with profound intellectual and multiple disabilities. However, there are also recommendations for research into the feasibility and acceptability of the instrument.
The effects of stress may be alleviated when its impact or a decreased stress-resilience are detected early. This study explores whether wearable-measured sleep and resting HRV in police officers can ...be predicted by stress-related Ecological Momentary Assessment (EMA) measures in preceding days and predict stress-related EMA outcomes in subsequent days. Eight police officers used an Oura ring to collect daily Total Sleep Time (TST) and resting Heart Rate Variability (HRV) and an EMA app for measuring demands, stress, mental exhaustion, and vigor during 15-55 weeks. Vector Autoregression (VAR) models were created and complemented by Granger causation tests and Impulse Response Function visualizations. Demands negatively predicted TST and HRV in one participant. TST negatively predicted demands, stress, and mental exhaustion in two, three, and five participants, respectively, and positively predicted vigor in five participants. HRV negatively predicted demands in two participants, and stress and mental exhaustion in one participant. Changes in HRV lasted longer than those in TST. Bidirectional associations of TST and resting HRV with stress-related outcomes were observed at a weak-to-moderate strength, but not consistently across participants. TST and resting HRV are more consistent predictors of stress-resilience in upcoming days than indicators of stress-related measures in prior days.
Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for ...measuring step count in both laboratory and free-living conditions.
Healthy adult volunteers (n = 33) walked twice on a treadmill (4.8 km/h) for 30 min while wearing ten different activity trackers (i.e. Lumoback, Fitbit Flex, Jawbone Up, Nike+ Fuelband SE, Misfit Shine, Withings Pulse, Fitbit Zip, Omron HJ-203, Yamax Digiwalker SW-200 and Moves mobile application). In free-living conditions, 56 volunteers wore the same activity trackers for one working day. Test-retest reliability was analyzed with the Intraclass Correlation Coefficient (ICC). Validity was evaluated by comparing each tracker with the gold standard (Optogait system for laboratory and ActivPAL for free-living conditions), using paired samples t-tests, mean absolute percentage errors, correlations and Bland-Altman plots.
Test-retest analysis revealed high reliability for most trackers except for the Omron (ICC .14), Moves app (ICC .37) and Nike+ Fuelband (ICC .53). The mean absolute percentage errors of the trackers in laboratory and free-living conditions respectively, were: Lumoback (-0.2, -0.4), Fibit Flex (-5.7, 3.7), Jawbone Up (-1.0, 1.4), Nike+ Fuelband (-18, -24), Misfit Shine (0.2, 1.1), Withings Pulse (-0.5, -7.9), Fitbit Zip (-0.3, 1.2), Omron (2.5, -0.4), Digiwalker (-1.2, -5.9), and Moves app (9.6, -37.6). Bland-Altman plots demonstrated that the limits of agreement varied from 46 steps (Fitbit Zip) to 2422 steps (Nike+ Fuelband) in the laboratory condition, and 866 steps (Fitbit Zip) to 5150 steps (Moves app) in the free-living condition.
The reliability and validity of most trackers for measuring step count is good. The Fitbit Zip is the most valid whereas the reliability and validity of the Nike+ Fuelband is low.
Short-term survival after solid-organ transplantation has substantially improved, and the focus has shifted to long-term survival, including the role of physical activity (PA). Knowledge about PA and ...sedentary time in recipients of solid-organ transplantation is limited, and identification of the levels and associated factors is necessary for intervention development.
The objectives of this study were to investigate the level of PA and sedentary time in recipients of solid-organ transplantation and to identify factors associated with these behaviors.
The design consisted of a cross-sectional survey.
Questionnaires on PA level, sedentary time, and potential associated factors were used for recipients of solid-organ transplantation (kidney, liver, lung, and heart N = 656). Multiple regression analyses with a variable selection procedure were used.
Fewer than 60% of the recipients fulfilled the PA guideline. Factors significantly associated with a lower level of PA included being a woman, younger age (nonlinear), not actively working or being retired, physical limitations, and low expectations and self-confidence. Factors significantly associated with less sedentary time included exercise self-efficacy and not actively working or being retired. Significantly associated with more sedentary time were a high education level, fear of negative effects, physical limitations, and the motivator "health and physical outcomes." The type of transplantation did not significantly influence either of the outcome measures.
The design did not allow for causal inferences to be made. The studied associated factors were limited to individual and interpersonal factors. Self-reported measures of PA and sedentary time were used.
In intervention development directed at increasing the level of PA and reducing sedentary time in recipients of solid-organ transplantation, attention should be paid to physical limitations, fear of negative effects, low expectations and self-confidence, health and physical outcomes, and exercise self-efficacy.
Consumer wearables health data may reflect the impact of pancreatic cancer and its treatment on cardiorespiratory fitness and the subsequent recovery after treatment. The patient is a 65-year-old ...male treated for borderline resectable pancreatic cancer. Treatment consisted of four courses of FOLFIRINOX neoadjuvant chemotherapy, a Whipple procedure with a right hemicolectomy and venous segment resection, and eight courses of adjuvant FOLFIRINOX chemotherapy. Physical activity and moderate to vigorous physical activity declined after the onset of symptoms, increased in the weeks before surgery, declined after surgery and then gradually recovered during and after adjuvant chemotherapy. Estimated VO2max remained stable during neoadjuvant chemotherapy, sharply decreased after surgery and then gradually recovered. Heart rate at rest increased and heart rate variability decreased after the onset of symptoms reaching their highest and lowest values after surgery. Both gradually returned to baseline seven months after the last course of chemotherapy. The physical impact of pancreatic cancer and its treatment and recovery was in this case reflected on consumer wearable health data. Seven months after the last chemotherapy recovery was close to baseline values.
Objective
To determine the effect of interventions on physical activity levels of patients awaiting abdominal resection surgery using self-reported as well as device-measured outcome measures.
Data ...source
PubMed and EMBASE databases were searched on the 18th of April 2023 up to April 2023 for studies on interventions to promote physical activity during the preoperative phase.
Review methods
Studies were included if pre- and post-intervention physical activity was measured between diagnosis and abdominal surgery. Risk of bias was assessed by the Physiotherapy Evidence Database (PEDro) assessment tool for trials. Meta-analyses were performed to assess the effect of the pre-surgery activity promoting interventions on self-reported and device-measured physical activity.
Results
Seventeen studies were included in the analysis with 452 subjects in the intervention groups. The random-effect meta-analysis showed a moderate improvement in intervention groups measures in pre-surgery physical activity levels compared to the baseline (SMD = 0.67, CI = 0.30;1.03, I2 = 79%). The self-reported subgroup meta-analysis showed the largest increase in performed physical activity, (SMD = 0.78, CI = 0.4;1.15, I2 = 79%) whilst non-significant increase was shown in the device-measured subgroup (SMD = 0.16, CI = −0.64;0.97, I2 = 58%).
Conclusion
Increasing physical activity in the preoperative phase is feasible. Self-reported physical activity outcome measures show larger effects compared to device-measured outcome measures. More high-quality research should be performed utilizing objective measures.