This study evaluated the accuracy of synthetic computed tomography (sCT), as compared to CT, for the 3D assessment of the hip morphology. Thirty male patients with asymptomatic hips, referred for ...magnetic resonance (MR) imaging and CT, were included in this retrospective study. sCT images were generated from three‐dimensional radiofrequency‐spoiled T1‐weighted multi‐echo gradient‐echo MR images using a commercially available deep learning‐enabled software and were compared with CT images through mean error and surface distance computation and by means of eight clinical morphometric parameters relevant for hip care. Parameters included center‐edge angle (CEA), sharp angle, acetabular index, extrusion index, femoral head center‐to‐midline distance, acetabular version (AV), and anterior and posterior acetabular sector angles. They were measured by two senior orthopedic surgeons and a radiologist in‐training on CT and sCT images. The reliability and agreement of CT‐ and sCT‐based measurements were assessed using intraclass correlation coefficients (ICCs) for absolute agreement, Bland–Altman plots, and two one‐sided tests for equivalence. The surface distance between CT‐ and sCT‐based bone models were on average submillimeter. CT‐ and sCT‐based measurements showed moderate to excellent interobserver and intraobserver correlation (0.56 < ICC < 0.99). In particular, the inter/intraobserver agreements were good for AV (ICC > 0.75). For CEA, the intraobserver agreement was good (ICC > 0.75) and the interobserver agreement was moderate (ICC > 0.69). Limits of agreements were similar between intraobserver CT and intermodal measurements. All measurements were found statistically equivalent, with average intermodal differences within the intraobserver limits of agreement. In conclusion, sCT and CT were equivalent for the assessment of the hip joint bone morphology.
This study compared magnetic resonance imaging‐based synthetic computed tomography (sCT) to conventional CT for the morphological assessment of the hip joint. The sCT generation technique reconstructed radiodensity contrast accurately, providing bone models within a submillimeter accuracy to CT‐based bone models. CT and sCT images were found statistically equivalent for measuring eight morphometric parameters clinically relevant in hip care. For both modalities, moderate to excellent interobserver and intraobserver reliability were obtained. This provides new possibilities in the radiation‐free diagnosis and surgical planning.
Prostate cancer patients with locoregional lymph node disease at diagnosis (N1M0) still have a limited prognosis despite the improvements provided by aggressive curative intent multimodal ...locoregional external beam radiation therapy (EBRT) with systemic androgen deprivation therapy (ADT). Although some patients can be cured and the majority of patients have a long survival, the 5-year biochemical failure rate is currently 29-47%.
LuLu-PSMA-617 has shown impressive clinical and biochemical responses with low toxicity in salvage setting in metastatic castration-resistant prostate cancer. This study aims to explore the combination of standard EBRT and ADT complemented with a single administration of
LuLu-PSMA-617 in curative intent treatment for N1M0 prostate cancer. Hypothetically, this combined approach will enhance EBRT to better control macroscopic tumour localizations, and treat undetected microscopic disease locations inside and outside EBRT fields.
The PROQURE-I study is a multicenter prospective phase I study investigating standard of care treatment (7 weeks EBRT and 3 years ADT) complemented with one concurrent cycle (three, six, or nine GBq) of systemic
LuLu-PSMA-617 administered in week two of EBRT. A maximum of 18 patients with PSMA-positive N1M0 prostate cancer will be included. The tolerability of adding
LuLu-PSMA-617 will be evaluated using a Bayesian Optimal Interval (BOIN) dose-escalation design. The primary objective is to determine the maximum tolerated dose (MTD) of a single cycle
LuLu-PSMA-617 when given concurrent with EBRT + ADT, defined as the occurrence of Common Terminology Criteria for Adverse Events (CTCAE) v 5.0 grade three or higher acute toxicity. Secondary objectives include: late toxicity at 6 months, dosimetric assessment, preliminary biochemical efficacy at 6 months, quality of life questionnaires, and pharmacokinetic modelling of
LuLu-PSMA-617.
This is the first prospective study to combine EBRT and ADT with
LuLu-PSMA-617 in treatment naïve men with N1M0 prostate cancer, and thereby explores the novel application of
LuLu-PSMA-617 in curative intent treatment. It is considered likely that this study will confirm tolerability as the combined toxicity of these treatments is expected to be limited. Increased efficacy is considered likely since both individual treatments have proven high anti-tumour effect as mono-treatments.
ClinicalTrials, NCT05162573 . Registered 7 October 2021.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Background/Aim
Patients with locally recurrent prostate cancer after primary radiotherapy can be eligible for salvage treatment. Whole-gland salvage techniques carry a high risk of toxicity. A
focal
...salvage approach might reduce the risk of adverse events while maintaining cancer control in carefully selected patients. The aim of this review was to evaluate current literature to assess whether focal salvage leads to a comparable or favourable recurrence rate and less toxicity compared to whole-gland salvage.
Methods
A literature search was performed using PubMed, Embase and the Cochrane Library. A total of 3015 articles were screened and assessed for quality. Eight papers on focal cryoablation (
n
= 3), brachytherapy (
n
= 3) and high-intensity focused ultrasound (
n
= 2) were used to report outcomes.
Results
One-, 2-, 3- and 5-year biochemical disease-free survival (BDFS) ranges for focal salvage are, respectively, 69–100, 49–100, 50–91 and 46.5–54.5 %. Severe genitourinary, gastrointestinal and sexual function toxicity rates are 0–33.3 %. One study directly compares focal to whole-gland salvage cryotherapy, showing 5-year BDFS of, respectively, 54.4 and 86.5 % with lower toxicity rates for focal salvage patients.
Conclusion
Provisional data suggest that BDFS rates of focal salvage are in line with those of whole-gland approaches. There is evidence that focal salvage could decrease severe toxicity and preserve erectile function.
To evaluate prostate intrafraction motion using MRI during the full course of online adaptive MR-Linac radiotherapy (RT) fractions, in preparation of MR-guided extremely hypofractionated RT.
Five low ...and intermediate risk prostate cancer patients were treated with 20 × 3.1 Gy fractions on a 1.5T MR-Linac. Each fraction, initial MRI (Pre) scans were obtained at the start of every treatment session. Pre-treatment planning MRI contours were propagated and adapted to this Pre scan after which plan re-optimization was started in the treatment planning system followed by dose delivery. 3D Cine-MR imaging was started simultaneously with beam-on and acquired over the full beam-on period. Prostate intrafraction motion in this cine-MR was determined with a previously validated soft-tissue contrast based tracking algorithm. In addition, absolute accuracy of the method was determined using a 4D phantom.
Prostate motion was completely automatically determined over the full on-couch period (approx. 45 min) with no identified mis-registrations. The translation 95% confidence intervals are within clinically applied margins of 5 mm, and plan adaption for intrafraction motion was required in only 4 out of 100 fractions.
This is the first study to investigate prostate intrafraction motions during entire MR-guided RT sessions on an MR-Linac. We have shown that high quality 3D cine-MR imaging and prostate tracking during RT is feasible with beam-on. The clinically applied margins of 5 mm have proven to be sufficient for these treatments and may potentially be further reduced using intrafraction plan adaptation guided by cine-MR imaging.
Structure delineation is a necessary, yet time-consuming manual procedure in radiotherapy. Recently, convolutional neural networks have been proposed to speed-up and automatise this procedure, ...obtaining promising results. With the advent of magnetic resonance imaging (MRI)-guided radiotherapy, MR-based segmentation is becoming increasingly relevant. However, the majority of the studies investigated automatic contouring based on computed tomography (CT).
In this study, we investigate the feasibility of clinical use of deep learning-based automatic OARs delineation on MRI.
We included 150 patients diagnosed with prostate cancer who underwent MR-only radiotherapy. A three-dimensional (3D) T1-weighted dual spoiled gradient-recalled echo sequence was acquired with 3T MRI for the generation of the synthetic-CT. The first 48 patients were included in a feasibility study training two 3D convolutional networks called DeepMedic and dense V-net (dV-net) to segment bladder, rectum and femurs. A research version of an atlas-based software was considered for comparison. Dice similarity coefficient, 95% Hausdorff distances (HD
), and mean distances were calculated against clinical delineations. For eight patients, an expert RTT scored the quality of the contouring for all the three methods. A choice among the three approaches was made, and the chosen approach was retrained on 97 patients and implemented for automatic use in the clinical workflow. For the successive 53 patients, Dice, HD
and mean distances were calculated against the clinically used delineations.
DeepMedic, dV-net and the atlas-based software generated contours in 60 s, 4 s and 10-15 min, respectively. Performances were higher for both the networks compared to the atlas-based software. The qualitative analysis demonstrated that delineation from DeepMedic required fewer adaptations, followed by dV-net and the atlas-based software. DeepMedic was clinically implemented. After retraining DeepMedic and testing on the successive patients, the performances slightly improved.
High conformality for OARs delineation was achieved with two in-house trained networks, obtaining a significant speed-up of the delineation procedure. Comparison of different approaches has been performed leading to the succesful adoption of one of the neural networks, DeepMedic, in the clinical workflow. DeepMedic maintained in a clinical setting the accuracy obtained in the feasibility study.
Adequate detection of the histopathological extraprostatic extension (EPE) of prostate cancer (PCa) remains a challenge using conventional radiomics on 3 Tesla multiparametric magnetic resonance ...imaging (3T mpMRI). This study focuses on the assessment of artificial intelligence (AI)-driven models with innovative MRI radiomics in predicting EPE of prostate cancer (PCa) at a lesion-specific level. With a dataset encompassing 994 lesions from 794 PCa patients who underwent robot-assisted radical prostatectomy (RARP) at two Dutch hospitals, the study establishes and validates three classification models. The models were validated on an internal validation cohort of 162 lesions and an external validation cohort of 189 lesions in terms of discrimination, calibration, net benefit, and comparison to radiology reporting. Notably, the achieved AUCs ranged from 0.86 to 0.91 at the lesion-specific level, demonstrating the superior accuracy of the random forest model over conventional radiological reporting. At the external test cohort, the random forest model was the best-calibrated model and demonstrated a significantly higher accuracy compared to radiological reporting (83% vs. 67%, p = 0.02). In conclusion, an AI-powered model that includes both existing and novel MRI radiomics improves the detection of lesion-specific EPE in prostate cancer.
The use of intraprostatic gold fiducial markers (FMs) ensures highly accurate and precise image-guided radiation therapy for patients diagnosed with prostate cancer thanks to the ease of localising ...FMs on photon-based imaging, like Computed Tomography (CT) images. Recently, Magnetic Resonance (MR)-only radiotherapy has been proposed to simplify the workflow and reduce possible systematic uncertainties. A critical, determining factor in the accuracy of such an MR-only simulation will be accurate FM localisation using solely MR images.
The aim of this study is to evaluate the performances of manual MR-based FM localisation within a clinical environment.
We designed a study in which 5 clinically involved radiation therapy technicians (RTTs) independently localised the gold FMs implanted in 16 prostate cancer patients in two scenarios: employing a single MR sequence or a combination of sequences. Inter-observer precision and accuracy were assessed for the two scenarios for localisation in terms of 95% limit of agreement on single FMs (LoA)/ centre of mass (LoA
) and inter-marker distances (IDs), respectively.
The number of precisely located FMs (LoA <2 mm) increased from 38/48 to 45/48 FMs when localisation was performed using multiple sequences instead of single one. When performing localisation on multiple sequences, imprecise localisation of the FMs (3/48 FMs) occurred for 1/3 implanted FMs in three different patients. In terms of precision, we obtained LoA
within 0.25 mm in all directions over the precisely located FMs. In terms of accuracy, IDs difference of manual MR-based localisation versus CT-based localisation was on average (±1 STD) 0.6 ±0.6 mm.
For both the investigated scenarios, the results indicate that when FM classification was correct, the precision and accuracy are high and comparable to CT-based FM localisation. We found that use of multiple sequences led to better localisation performances compared with the use of single sequence. However, we observed that, due to the presence of calcification and motion, the risk of mislocated patient positioning is still too high to allow the sole use of manual FM localisation. Finally, strategies to possibly overcome the current challenges were proposed.
Background
Pelvic morphological parameters on magnetic resonance imaging (MRI), such as the membranous urethral length (MUL), can predict urinary incontinence after radical prostatectomy but are ...prone to interobserver disagreement. Our objective was to improve interobserver agreement among radiologists in measuring pelvic parameters using deep learning (DL)-based segmentation of pelvic structures on MRI scans.
Methods
Preoperative MRI was collected from 167 prostate cancer patients undergoing radical prostatectomy within our regional multicentric cohort. Two DL networks (nnU-Net) were trained on coronal and sagittal scans and evaluated on a test cohort using an 80/20% train-test split. Pelvic parameters were manually measured by three abdominal radiologists on raw MRI images and with the use of DL-generated segmentations. Automated measurements were also performed for the pelvic parameters. Interobserver agreement was evaluated using the intraclass correlation coefficient (ICC) and the Bland–Altman plot.
Results
The DL models achieved median Dice similarity coefficient (DSC) values of 0.85–0.97 for coronal structures and 0.87–0.98 for sagittal structures. When radiologists used DL-generated segmentations of pelvic structures, the interobserver agreement for sagittal MUL improved from 0.64 (95% confidence interval 0.28–0.83) to 0.91 (95% CI 0.84–0.95). Furthermore, there was an increase in ICC values for the obturator internus muscle from 0.74 (95% CI 0.42–0.87) to 0.86 (95% CI 0.75–0.92) and for the levator ani muscle from 0.40 (95% CI 0.05–0.66) to 0.61 (95% CI 0.31–0.78).
Conclusions
DL-based automated segmentation of pelvic structures improved interobserver agreement in measuring pelvic parameters on preoperative MRI scans.
Relevance statement
The implementation of deep learning segmentations allows for more consistent measurements of pelvic parameters by radiologists. Standardized measurements are crucial for incorporating these parameters into urinary continence prediction models.
Key points
• DL-generated segmentations improve interobserver agreement for pelvic measurements among radiologists.
• Membranous urethral length measurement improved from substantial to almost perfect agreement.
• Artificial intelligence enhances objective pelvic parameter assessment for continence prediction models.
Graphical Abstract
Abstract Purpose Whole-gland salvage for recurrent prostate cancer (PCa) shows high failure and toxicity rates. Early and adequate localization of recurrences enables focal salvage, thereby ...potentially improving functional outcomes, while maintaining cancer control. Materials and methods Retrospective analysis yielded 20 focal salvage I125 brachytherapy patients for locally recurrent PCa after primary radiotherapy. Tumor was defined by multiparametric MRI and correspondence with transrectal biopsies. Dose data were obtained intra-operatively. The tumor was prescribed ⩾144 Gy. Toxicity was scored by the Common Terminology Criteria for Adverse Events version 4 (CTCAE-4). Biochemical failure (BF) was defined using the Phoenix criteria (PSA-nadir + 2.0 ng/ml). Quality of life (QoL) was measured by SF-36 Health Survey and European Organization of Research and Treatment of Cancer (EORTC) C30+3 and PR25 questionnaires. Results With a median follow-up of 36 months (range 10–45), six patients experienced BF, of which three had no initial response. Grade 3 genitourinary (GU) toxicity occurred in one patient (a urethral stricture). The five previously potent patients retained erectile function. QoL remained decreased with regard to urinary symptoms. Conclusion Focal salvage I125 brachytherapy showed one grade 3 GU toxicity in the 20 treated patients. Biochemical response and QoL were acceptable.
Magnetic resonance imaging (MRI) is often combined with computed tomography (CT) in prostate radiotherapy to optimise delineation of the target and organs-at-risk (OAR) while maintaining accurate ...dose calculation. Such a dual-modality workflow requires two separate imaging sessions, and it has some fundamental and logistical drawbacks. Due to the availability of new MRI hardware and software solutions, CT examinations can be omitted for prostate radiotherapy simulations. All information for treatment planning, including electron density maps and bony anatomy, can nowadays be obtained with MRI. Such an MRI-only simulation workflow reduces delineation ambiguities, eases planning logistics, and improves patient comfort; however, careful validation of the complete MRI-only workflow is warranted. The first institutes are now adopting this MRI-only workflow for prostate radiotherapy. In this article, we will review technology and workflow requirements for an MRI-only prostate simulation workflow.
•MRI-only workflows are being implemented in several centres for prostate cancer;•Before the introduction of an MRI-only workflow in clinical practice, the building blocks of this workflow should be implemented and validated.•MRI-only workflows are useful both in the context of X-ray or CBCT-guided radiotherapy as well as MRI-guided radiotherapy.