-
Pozna reakcija mehkih tkiv ob kovinskih vsadkih, prekritih s hidroksiapatitom, pri ovcah : magistrsko deloVidmar, Jerneja, nevrobiologija, 1971-Hydroxyapatite coatings of metal implants that are used in traumatology and orthopaedics are at some types of these implants also in direct contact with the soft tissues. The aim of this study is to ... find out what is the late soft tissue reaction on hydroxyapatite coating of metal implants which have some specific properties and are implanted between the skeletal muscles of the femoral region in sheep. We expect that the late inflammatory reaction around coated implants will be less intensive than around uncoated implants. Hydroxyapatite is a biocompatible material, stainless steel on the other hand is not very biocompatible because it is prone to corrosion. Four hydroxyapatite coated Schanz screws were implanted into one femur and four uncoated Schanz screws into the other femur of each sheep so that the screws remained also between the skeletal muscles and subcutaneous tissue. The animals were sacrificed 2 and 6 months after the implantation. The segments ofsoft tissue near the screws were obtained immediately after the sacrifice. Macroscopic descriptions of the specimens were done. Histomorphological analysis was performed by light and electron microscopy, quantitative analysisof the specimens was done. Analysis of the specimens indicates the presence of three distinct layers near the implants. Next to the implant thereis the pseudosynovial membrane which is followed by the granulomatous layer. Further away from the implant there is the connective tissue. This is histological picture of chronical granulomatous inflammatory reaction. Differences in mean values of the width of layers and average percentages of component cells in the granulomatous layers of test and control group are not statistically significant. Only the difference in mean values of cellularity of the granulomatous layers is significant.Vrsta gradiva - magistrsko delo ; neleposlovje za odrasleZaložništvo in izdelava - Ljubljana : [J. Vidmar], 2000Jezik - slovenskiCOBISS.SI-ID - 2240276
Avtor
Vidmar, Jerneja, nevrobiologija, 1971-
Drugi avtorji
Smrkolj, Vladimir, upokojen
Teme
Bone screws |
Adverse effects |
Durapatite |
Adverse effects |
Stainless steel |
Adverse effects |
Inflammation |
Etiology |
Kostni vijaki |
Škodljivi učinki |
Durapatit |
Škodljivi učinki |
Nerjaveče jeklo |
Škodljivi učinki |
Vnetje |
Etiologija |
ortopedija |
kovinski vsadki |
hidroksiapatit |
nerjaveče jeklo |
mehka tkiva |
vnetni odziv |
biokompatibilnost |
magistrske naloge
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Knjižnica | Signatura – lokacija, inventarna št. ... | Status izvoda |
---|---|---|
Narodna in univerzitetna knjižnica, Ljubljana | GS II 708460 glavno skladišče | prosto - za čitalnico |
MF, Centralna medicinska knjižnica, Ljubljana | magistrske naloge VIDMAR Jerneja Pozna IN: 020010111 |
prosto - na dom, čas izposoje: 1 mes. |
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Vidmar, Jerneja, nevrobiologija, 1971- | 19214 |
Smrkolj, Vladimir, upokojen | 03250 |
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Obvestilo
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Mesto prevzema | Status gradiva | Rezervacija |
---|
Prosimo, počakajte trenutek.