Lenz, Philipp; Domagk, Dirk
Gastrointestinal endoscopy clinics of North America, 01/2017, Letnik: 27, Številka: 1Journal Article
Single-balloon enteroscopy is among 3 device-assisted enteroscopy systems on the market. Compared with double-balloon enteroscopy, no significant difference in diagnostic yield was found. Additionally, no significant difference was found in oral and anal insertion depth, adverse events, or procedure times. Some studies observed lower complete enteroscopy rates, which have evidently no diagnostic impact. With a learning curve of around 30 procedures, the single-balloon endoscope is a safe endoscopic tool, which seems equally suitable for diagnostic and therapeutic interventions. Carbon dioxide should be used for single-balloon endoscopy procedures, especially in patients with a history of surgical abdominal interventions.