E-viri
Recenzirano
Odprti dostop
-
Zeidan-Shwiri, Tawfiq; Yang, Yuesong; Lashevsky, Ilan; Kadmon, Ehud; Kagal, Darren; Dick, Alexander; Laish Farkash, Avishag; Paul, Gideon; Gao, Donsheng; Shurrab, Mohammed; Newman, David; Wright, Graham; Crystal, Eugene
Heart rhythm, 04/2015, Letnik: 12, Številka: 4Journal Article
The majority of patients receiving implantable cardioverter-defibrillator (ICD) implantation under current guidelines never develop sustained ventricular arrhythmia; therefore, better markers of risk for sustained ventricular tachycardia and/or ventricular fibrillation are needed. The purpose of this study was to identify cardiac magnetic resonance arrhythmic risk predictors of ischemic cardiomyopathy before ICD implantation. Forty-three subjects (mean age, 64.5 ± 11.9 years) with previous myocardial infarction who were referred for ICD implantation were evaluated by cardiac magnetic resonance imaging (MRI). The MRI protocol included left ventricular functional parameter assessment using steady-state free precession and late gadolinium enhancement MRI using inversion recovery fast gradient echo. Left ventricular functional parameters were measured using cardiac magnetic resonance software. Subjects were followed up for 6-46 months, and the events of appropriate ICD treatments (shocks and antitachycardia pacing) were recorded. Twenty-eight patients experienced 46 spontaneous episodes during a median follow-up duration of 30 months. The total myocardial infarct (MI) size (18.05 ± 11.44 g vs 38.83 ± 19.87 g; P = .0006), MI core (11.63 ± 7.14 g vs 24.12 ± 12.73 g; P = .0002), and infarct gray zone (6.43 ± 4.64 g vs 14.71 ± 7.65 g; P = .0004) were significantly larger in subjects who received appropriate ICD therapy than in those who did not experience an episode of ventricular tachycardia and/or ventricular fibrillation. Multivariate regression analyses for the infarct gray zone and MI core adjusted for New York Heart Association class, diabetes, and etiology (primary or secondary prevention) revealed that the gray zone and MI core were predictors of appropriate ICD therapies (P = .0018 and P = .007, respectively). The extent of MI scar may predict which patients would benefit most from ICD implantation.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.