Jason L Cantera; Lorraine M Lillis; Roger B Peck; Emmanuel Moreau; James A Schouten; Paul Davis; Paul K Drain; Alfred Andama; Abraham Pinter; Masanori Kawasaki; Gunilla Källenius; Christopher Sundling; Karen M Dobos; Danara Flores; Delphi Chatterjee; Eileen Murphy; Olivia R Halas; David S Boyle
PloS one, 09/2022, Letnik: 17, Številka: 9Journal Article
Lipoarabinomannan (LAM), a component of the Mycobacterium tuberculosis (MTB) cell wall, is detectable in the urine of MTB infected patients with active tuberculosis (TB). LAM-specific antibodies (Igs) have been developed by a variety of traditional and recombinant methods for potential use in a rapid diagnostic test (RDT). We evaluated the analytical performance of the TB LAM Igs to identify pairs that offer superior performance over existing urine LAM tests. We assessed 25 new and 4 existing Igs in a matrixed format using a multiplex electrochemiluminescence-based liquid immunoassay. A total of 841 paired Ig combinations were challenged with in vitro cultured LAM (cLAM) derived from MTB strains representing diverse phylogenetic lineages, alongside urinary LAM (uLAM) from the urine of adults with active pulmonary TB. Analytical sensitivity of down-selected Ig pairs was determined using MTB Aoyama-B cLAM, while diagnostic accuracy was determined using clinical samples. When testing cLAM, the reactivity of Ig pairs was similar across MTB lineages 1-4 but lineage 5:6 had significantly more reactivity among Ig pairs. Overall, 41 Ig pairs had a strong binding affinity to cLAM, as compared to the reference pair of S4-20/A194-01, and 28 Ig pairs therein exhibited a strong affinity for both cLAM and uLAM. Retrospective testing on clinical urine specimens demonstrated varying sensitivities (12-80%) and specificities (14-100%). The five top pairs had a similar analytical limit of detection to the reference pair but in four instances, the sensitivity and specificity with clinical uLAM samples was poor. Overall, epitopes presented by uLAM are different from cLAM, which may affect antibody performance when testing uLAM in patient samples. Several new Ig pairs had similar ranges of high sensitivity to cLAM but overall, there were no new candidate Ig pairs identified in this round of screening with increased performance with uLAM as compared to an existing optimal pair.
Avtor
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.