Iizuka, Kei; Nishinaka, Tomohiro; Akiyama, Daichi; Sumikura, Hirohito; Mizuno, Toshihide; Tsukiya, Tomonori; Takewa, Yoshiaki; Yamazaki, Kenji; Tatsumi, Eisuke
Journal of artificial organs, 12/2018, Letnik: 21, Številka: 4Journal Article
Aortic insufficiency (AI) is a crucial complication during continuous-flow left ventricular assist device (LVAD) support. Our previous clinical study suggested that a larger angle between the outflow graft and the aorta (O–A angle) could cause AI progression. This study examined the effect of the O–A angle on the hemodynamics of AI under LVAD support in an acute animal experimental model. An LVAD was installed in seven calves, with the inflow cannula inserted from the LV apex and with the outflow graft sutured at the ascending aorta. The AI model was made using a temporary inferior vena cava filter inserted from the LV apex and placed at the aortic valve. Cardiac dysfunction was induced by continuous beta-blocker infusion. Hemodynamic values and the myocardial oxygen extraction rate (O 2 ER) were evaluated at three O–A angles (45°, 90°, and 135°) over three levels of AI (none, Sellers I–II AI, and Sellers III–IV AI). The recirculation rate, defined as the percentage of regurgitation flow to LVAD output, was calculated. Systemic flow tended to decrease with a larger O–A angle. The recirculation rate was significantly increased with a larger O–A angle (22, 23, and 31% at 45°, 90°, and 135° in Sellers III–IV AI, respectively). Coronary artery flow was decreased at a larger O–A angle (86, 76 and 75 mL/min at 45°, 90°, and 135° in Sellers I–II AI, respectively, and 77, 67, and 56 mL/min at 45°, 90°, and 135° in Sellers III–IV AI, respectively). O 2 ER tended to increase with a larger O–A angle (40, 43, and 49% at 45°, 90°, and 135° in Sellers III–IV AI, respectively). A larger O–A angle can increase the recirculation due to AI and can be disadvantageous to LVAD-AI hemodynamics and myocardial oxygen metabolism.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.