E-viri
Recenzirano
-
Bourcier, Romain; Legrand, Laurence; Soize, Sébastien; Labreuche, Julien; Beaumont, Marine; Desal, Hubert; Derraz, Imad; Bracard, Serge; Oppenheim, Catherine; Naggara, Olivier
European radiology, 05/2019, Letnik: 29, Številka: 5Journal Article
Objective We aimed to determine in the “THRACE” trial, the clinical and MRI technical parameters associated with the two-layered susceptibility vessel sign (TL-SVS) and the overestimation ratio (overR). Materials and methods Patients with pre-treatment brain gradient echo (GRE) sequence and an etiological work-up were identified. Two readers reviewed TL-SVS, i.e., a SVS with a linear low-intense signal core surrounded by a higher intensity and measured the overR as the width of SVS divided by the width of the artery. Binomial and ordinal logistic regression respectively tested the association between TL-SVS and quartiles of overR with patient characteristics, cardioembolic stroke (CES), time from onset to imaging, and GRE sequence parameters (inter slice gap, slice thickness, echo time, flip angle, voxel size, and field strength). Results Among 258 included patients, 102 patients were examined by 3 Tesla MRI and 156 by 1.5 Tesla MRI. Intra- and inter-reader agreements for quartiles of overR and TL-SVS were good to excellent. The median overR was 1.59 (IQR, 1.30 to 1.86). TL-SVS was present in 101 patients (39.2%, 95%CI, 33.1 to 45.1%). In multivariate analysis, only CES was associated with overR quartiles (OR, 1.83; 95%CI, 1.11 to 2.99), and every 60 min increase from onset to MRI time was associated with TL-SVS (OR, 1.72; 95%CI, 1.10 to 2.67). MRI technical parameters were statistically associated with neither overR nor TL-SVS. Conclusion Independent of GRE sequence parameters, an increased overR was associated to CES, while the TL-SVS is independently related to a longer time from onset to MRI. Key Points • An imaging biomarker would be useful to predict the etiology of stroke in order to adapt secondary prevention of stroke. • The two-layered susceptibility vessel sign and the overestimation ratio are paramagnetic effect derived markers that vary according to the MRI machines and sequence parameters. • Independent of sequence parameters, an increased overestimation ratio was associated to cardioembolic stroke, while the two-layered susceptibility vessel sign is independently related to a longer time from onset to MRI.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.