E-viri
Recenzirano
-
Zhu, Yuan-Cheng; Xu, Fei; Zhang, Nan; Zhao, Wei-Wei; Xu, Jing-Juan; Chen, Hong-Yuan
Biosensors & bioelectronics, 05/2017, Letnik: 91Journal Article
This work reports the use of compositionally heterogeneous asymmetric Ag@Au core–satellite nanoassembly functionalized with DNA sequence as unique signaling nanoprobes for the realization of new energy-transfer-based photoelectrochemical (PEC) immunoassay of prostate- specific antigen (PSA). Specifically, the Ag@Au asymmetric core–satellite nanoassemblies (Ag@Au ACS) were fabricated on a two-dimensional glass substrate by a modified controlled assembly technique, and then functionalized with DNA sequences containing PSA aptamers as signaling nanoprobes. Then, the sandwich complexing between the PSA, its antibodies, and the signaling nanoprobes was performed on a CdS QDs modified indium tin oxide (ITO) electrode. The single stranded DNA can server as a facile mediator that place the Ag@Au ACS in proximity of CdS QDs, stimulating the interparticle exciton–plasmon interactions between Ag@Au ACS and CdS QDs and thus quenching the excitonic states in the latter. Since the damping effect is closely related to the target concentration, a novel energy-transfer-based PEC bioanalysis could be achieved for the sensitive and specific PSA assay. The developed biosensor displayed a linear range from 1.0×10−11gmL−1 to 1.0×10−7gmL−1 and the detection limit was experimentally found to be of 0.3×10–13gmL−1. This strategy used the Ag@Au ACS-DNA signaling nanoprobes and overcame the deficiency of short operating distance of the energy transfer process for feasible PEC immunoassay. More significantly, it provided a way to couple the plasmonic properties of the Ag NPs and Au NPs in a single PEC bioanalytical system. We expected this work could inspire more interests and further investigations on the advanced engineering of the core–satellite or other judiciously designed nanostructures for new PEC bioanalytical uses with novel properties. •Ag@Au asymmetric core–satellite nanoassembly was fabricated.•It was then applied for the novel energy-transfer-based PEC immunoassay.•The proposed format could serve as a general basis for PEC bioanalysis.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.