E-viri
Recenzirano
-
Guerrero-Rodríguez, N.F.; Herrero-de Lucas, L.C.; de Pablo-Gómez, S.; Rey-Boué, Alexis. B.
Electric power systems research, 11/2014, Letnik: 116Journal Article
•This paper gives a performance study of the Positive Sequence Detector plus a dqPLL.•A real-time digital simulation platform is used to validate the results.•With low-level harmonic pollution it is not a necessity to use a complicated synchronization algorithm.•A significant attenuation of the harmonic contamination is attained when the PSD block is used.•A good power factor can be obtained even though variations in frequency occur. In a distributed generation (DG) system, several renewable agents are connected to the low-voltage 3-phase utility grid through an inverter which is used as power condition and must guarantee the higher efficiency of the renewable agent. To attain this level of efficiency, a unitary power factor (FP) between the inverter currents and the utility grid voltages is necessary, and a synchronization algorithm is needed for the perfect synchronization between the renewable agent and the 3-phase utility grid. Within this context, this paper gives a performance study of the Positive Sequence Detector plus a Synchronous Reference Frame Phase-Locked Loop (PSD+dqPLL) as the synchronization algorithm, evaluating its accuracy under different conditions and studying their advantages and drawbacks. A grid-connected photovoltaic system with a nominal power of 6kW is used so as to evaluate the behavior of the synchronization algorithm when the 3-phase utility grid is affected by some disturbances such as voltage unbalances, frequency variations and harmonic distortions. Firstly, several simulations with a disturbed 3-phase utility grid using MATLAB/SIMULINK from The MathWorks, Inc. are shown, and secondly, the previous tests are run in a Real-Time Digital Simulation (RTDS) platform in order to validate the obtained results with simulations.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.