Kereiakes, Dean J., MD; Ellis, Stephen G., MD; Kimura, Takeshi, MD; Abizaid, Alexandre, MD, PhD; Zhao, Weiying, MD, PhD; Veldhof, Susan, RN; Vu, Minh-Thien, MS; Zhang, Zhen, PhD; Onuma, Yoshinobu, MD, PhD; Chevalier, Bernard, MD; Serruys, Patrick W., MD, PhD; Stone, Gregg W., MD
JACC. Cardiovascular interventions, 01/2017, Letnik: 10, Številka: 1Journal Article
Abstract Objectives The study sought to evaluate the efficacy and safety of the Absorb everolimus-eluting bioresorbable vascular scaffold (BVS) (Abbott Vascular, Abbott Park, Illinois) in patients with diabetes mellitus. Background Randomized, controlled trials have demonstrated comparable clinical outcomes following percutaneous coronary intervention with either Absorb BVS or metallic Xience everolimus-eluting stent. However, these trials lack power required to provide reliable treatment effect estimates in this high-risk population. Methods In a pre-specified, powered analysis, patients with diabetes who received ≥1 Absorb were pooled from the ABSORB II, III, and JAPAN randomized trials and from the single arm ABSORB EXTEND registry. The study composite primary endpoint was target lesion failure (TLF) at 1 year following Absorb BVS compared with a performance goal of 12.7%. Results Among 754 diabetic patients included in analysis (27.3% insulin treated), the 1-year TLF rate was 8.3% (upper 1-sided 95% confidence limit: 10.1%; p = 0.0001 vs. performance goal). Scaffold thrombosis (definite or probable) was observed in 2.3% of patients. Multivariable regression identified older age, insulin treatment, and smaller pre-procedure reference vessel diameter as significant independent predictors of 1-year TLF. Conclusions The Absorb diabetic substudy suggests efficacy and safety of the Absorb BVS for treatment of patients with diabetes mellitus.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.