Iacovelli, Fortunato; Giugliano, Giuseppe; Gerardi, Donato; Salemme, Luigi; Cioppa, Angelo; Pucciarelli, Armando; Popusoi, Grigore; Loizzi, Francesco; Schettino, Giancarlo; Favale, Stefano; Solimene, Francesco; Esposito, Giovanni; Tesorio, Tullio; Stabile, Eugenio
Heart and vessels, 02/2022, Letnik: 37, Številka: 2Journal Article
Performing transcatheter aortic valve implantation with high implantation technique, i.e. with an aorto-ventricular ratio > 60/40, reduces the need of permanent pacemaker implantation. Valve calcification and prosthesis oversizing are predictors of permanent pacemaker implantation, but there are no available data on their role when transcatheter aortic valve implantation is performed with an aorto-ventricular ratio > 60/40. The aim of this study was to evaluate the effect of leaflets/annulus calcification and prosthesis oversizing on the incidence of permanent pacemaker implantation after transcatheter aortic valve implantation with a high implantation technique. Transcatheter aortic valve implantation was performed in 48 patients implanting a balloon-expandable transcatheter heart valve with an aorto-ventricular ratio > 60/40. Calcium burden was assessed by preprocedural multidetector computed tomography. An invasive electrophysiological study was performed before and after transcatheter aortic valve implantation. Five patients (10.4%) needed permanent pacemaker implantation. At univariate analysis, baseline right bundle branch block and postprocedural PR, QRS and His-ventricular interval elongation significantly predicted permanent pacemaker implantation ( p < 0.05). Receiver-operating characteristic curve analysis showed a correlation between transcatheter heart valve oversizing and permanent pacemaker implantation need, with the best cut-off being 17% (AUC = 0.72, p = 0.033). Linear regression analysis demonstrated that QRS complex elongation was related to total, left and non-coronary leaflet calcification ( p < 0.05). This study demonstrates that, when transcatheter aortic valve implantation is performed using a balloon-expandable transcatheter heart valve deployed with an aorto-ventricular ratio > 60/40, the presence of leaflets/annulus calcification or the need to oversize the prosthesis correlate with the occurrence of pathological cardiac conduction delays.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.