E-viri
Recenzirano
Odprti dostop
-
Migueles, Jairo H.; Cadenas-Sanchez, Cristina; Alcantara, Juan M. A.; Leal-Martín, Javier; Mañas, Asier; Ara, Ignacio; Glynn, Nancy W.; Shiroma, Eric J.
Sensors (Basel, Switzerland), 05/2021, Letnik: 21, Številka: 10Journal Article
Accelerometers’ accuracy for sedentary time (ST) and moderate-to-vigorous physical activity (MVPA) classification depends on accelerometer placement, data processing, activities, and sample characteristics. As intensities differ by age, this study sought to determine intensity cut-points at various wear locations people more than 70 years old. Data from 59 older adults were used for calibration and from 21 independent participants for cross-validation purposes. Participants wore accelerometers on their hip and wrists while performing activities and having their energy expenditure measured with portable calorimetry. ST and MVPA were defined as ≤1.5 metabolic equivalents (METs) and ≥3 METs (1 MET = 2.8 mL/kg/min), respectively. Receiver operator characteristic (ROC) analyses showed fair-to-good accuracy (area under the curve AUC = 0.62–0.89). ST cut-points were 7 mg (cross-validation: sensitivity = 0.88, specificity = 0.80) and 1 count/5 s (cross-validation: sensitivity = 0.91, specificity = 0.96) for the hip; 18 mg (cross-validation: sensitivity = 0.86, specificity = 0.86) and 102 counts/5 s (cross-validation: sensitivity = 0.91, specificity = 0.92) for the non-dominant wrist; and 22 mg and 175 counts/5 s (not cross-validated) for the dominant wrist. MVPA cut-points were 14 mg (cross-validation: sensitivity = 0.70, specificity = 0.99) and 54 count/5 s (cross-validation: sensitivity = 1.00, specificity = 0.96) for the hip; 60 mg (cross-validation: sensitivity = 0.83, specificity = 0.99) and 182 counts/5 s (cross-validation: sensitivity = 1.00, specificity = 0.89) for the non-dominant wrist; and 64 mg and 268 counts/5 s (not cross-validated) for the dominant wrist. These cut-points can classify ST and MVPA in older adults from hip- and wrist-worn accelerometers.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.