E-viri
Recenzirano
Odprti dostop
-
LE, Quynh-Thu; QIANG ZHANG; LEE, Nancy; KIAN ANG, K; CHAN, Anthony T. C; CHAN, K. C. Allen; HONGBIN CAO; CHENG, Ann-Joy; PINSKY, Benjamin A; HONG, Ruey-Long; CHANG, Joseph T; WANG, Chun-Wei; TSAO, Kuo-Chien; LO, Ym Dennis
Clinical cancer research, 04/2013, Letnik: 19, Številka: 8Journal Article
Persistently elevated posttreatment plasma EBV DNA is a robust predictor of relapse in nasopharyngeal carcinoma (NPC). However, assay standardization is necessary for use in biomarker-driven trials. We conducted a study to harmonize the method between four centers with expertise in EBV DNA quantitation. Plasma samples of 40 patients with NPC were distributed to four centers. DNA was extracted and EBV DNA copy number was determined by real-time quantitative PCR (BamHI-W primer/probe). Centers used the same protocol but generated their own calibrators. A harmonization study was then conducted using the same calibrators and PCR master mix and validated with ten pooled samples. The initial intraclass correlations (ICC) for the first 40 samples between each center and the index center were 0.62 95% confidence interval (CI): 0.39-0.78, 0.70 (0.50-0.83), and 0.59 (0.35-0.76). The largest variability was the use of different PCR master mixes and calibrators. Standardization improved ICC to 0.83 (0.5-0.95), 0.95 (0.83-0.99) and 0.96 (0.86-0.99), respectively, for ten archival frozen samples. For fresh plasma with spiked-in EBV DNA, correlations were more than 0.99 between the centers. At 5 EBV DNA copies per reaction or above, the coefficient of variance (CV) was less than 10% for the cycle threshold (Ct) among all centers, suggesting this concentration can be reliably used as a cutoff for defining the presence of detectable EBV DNA. Quantitative PCR assays, even when conducted in experienced clinical labs, can yield large variability in plasma EBV DNA copy numbers without harmonization. The use of common calibrators and PCR master mix can help to reduce variability.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.