Akademska digitalna zbirka SLovenije - logo
E-viri
Celotno besedilo
Recenzirano
  • Percutaneous left ventricul...
    Mazzaferri, Ernest L., MD; Gradinac, Sinisa, MD; Sagic, Dragan, MD; Otasevic, Petar, MD; Hasan, Ayesha K., MD; Goff, Thomas L., MD; Sievert, Horst, MD; Wunderlich, Nina, MD; Nikolic, Serjan D., PhD; Abraham, William T., MD

    The American heart journal, 05/2012, Letnik: 163, Številka: 5
    Journal Article

    Objectives The aim of this study was to assess the feasibility, safety, and preliminary efficacy of a novel percutaneous left ventricular partitioning device (VPD) in patients with chronic heart failure (HF) and a prior anterior myocardial infarction. Background Anterior myocardial infarction is frequently followed by left ventricular remodeling, HF, and increased long-term morbidity and mortality. Methods Thirty-nine patients were enrolled in a multinational, nonrandomized, longitudinal investigation. The primary end point was an assessment of safety, defined as the successful delivery and deployment of the VPD and absence of device-related major adverse cardiac events over 6 months. Secondary (exploratory) efficacy end points included changes in hemodynamics and functional status and were assessed serially throughout the study. Results Ventricular partitioning device placement was not attempted in 5 (13%) of 39 subjects. The device was safely and successfully implanted in 31 (91%) of the remaining 34 patients or 79% of all enrolled patients. The 6-month rate of device-related major adverse cardiac event occurred in 5 (13%) of 39 enrolled subjects and 5 (15%) of 34 treated subjects, with 1 additional event occurring between 6 and 12 months. For patients discharged with the device to 12 months (n = 28), New York Heart Association class (2.5 ± 0.6 to 1.3 ± 0.6, P < .001) and quality-of-life scores (38.6 ± 6.1 to 28.4 ± 4.4, P < .002) improved significantly; however, the 6-minute hall walk distance (358.5 ± 20.4 m to 374.7 ± 25.6 m, P nonsignificant) only trended toward improvement. Conclusions The left VPD appears to be relatively safe and potentially effective in the treatment for patients with HF and a prior anterior myocardial infarction. However, these limited results suggest the need for further evaluation in a larger randomized controlled trial.