How, Alicia C; Baskaran, Mani; Kumar, Rajesh S; He, Mingguang; Foster, Paul J; Lavanya, Raghavan; Wong, Hon-Tym; Chew, Paul T K; Friedman, David S; Aung, Tin
Ophthalmology (Rochester, Minn.), 07/2012, Letnik: 119, Številka: 7Journal Article
Novel anterior segment optical coherence tomography (ASOCT) parameters associated with angle closure include anterior chamber area (ACA), anterior chamber volume (ACV), anterior chamber width (ACW), lens vault (LV), iris thickness (IT), iris area (I-area), and iris curvature (I-curv). We aimed to investigate changes in these parameters after laser peripheral iridotomy (LPI) in a cohort of primary angle-closure suspects (PACS). Prospective observational study. A total of 176 PACS aged ≥ 50 years who underwent LPI in 1 eye. We analyzed ASOCT images (Visante, Carl Zeiss Meditec, Dublin, CA) from all subjects using customized software before and 1 week after LPI. Multivariate linear regression analysis was performed for predictors of percentage change in mean angle opening distance (AOD750). Change in ASOCT parameters after LPI. The mean age of participants was 63 ± 7.3 years. The majority of subjects were Chinese (95.5%) and women (76.7%). Mean angle width (modified Shaffer grade) changed from 0.68 ± 0.54 at baseline to 1.76±0.69 after LPI (P<0.001) with a corresponding increase in mean AOD500 (0.12 vs. 0.19 mm, P<0.001), trabecular iris surface area (TISA500, 0.06 vs. 0.08 mm(2), P<0.001), and angle recess area (ARA, 0.13 vs. 0.17 mm(2), P<0.001). Mean ACA (15.0 vs. 16.0 mm(2), P<0.001) and ACV (91.6 vs. 103.0 mm(3), P<0.001) increased significantly after LPI, but there was no change in ACW, anterior chamber depth (ACD), or LV. Mean I-curv was reduced (0.375 vs. 0.18 mm, P<0.001) after LPI, but there was no significant change in IT or I-area. After multivariate analysis, mean LV (β = 0.286, P = 0.001), mean IT at 2000 μm (IT2000, β = 0.172, P = 0.034), and intraocular pressure (β = 0.159, P = 0.042) at baseline were found to be associated with ΔAOD750. This study confirms that LPI results in a significant increase in the angle width in PACS. The ACA and ACV increased after LPI, but there was no change in ACD, ACW, LV, IT, or I-area. The increase in ACA/ACV was mainly due to decreased I-curv after LPI.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.