E-viri
Recenzirano
Odprti dostop
-
Kitahara, Hideki; Okada, Kozo; Kimura, Takumi; Yock, Paul G; Lansky, Alexandra J; Popma, Jeffrey J; Yeung, Alan C; Fitzgerald, Peter J; Honda, Yasuhiro
Circulation. Cardiovascular interventions 10, Številka: 10Journal Article
Although significant undersizing often results in incomplete stent apposition or underexpansion, the possible impact of oversized stent implantation on arterial wall injury has not been systematically investigated with drug-eluting stents. The aim of this study was to investigate the impact of stent oversizing on acute and long-term outcomes after drug-eluting stents implantation in de novo coronary lesions. Serial (baseline and 6-12 months) coronary angiography and intravascular ultrasound were performed in 2931 lesions treated with drug-eluting stents (355 sirolimus, 846 paclitaxel, 1387 zotarolimus, and 343 everolimus). The percentage of stent oversizing to angiographic reference vessel diameter (RVD) was calculated as (nominal stent diameter-RVD)/RVD×100 (%). Clinical outcomes, including target lesion revascularization and stent thrombosis, were followed for 1 year. Overall, smaller preintervention RVD was associated with higher percentage of stent oversizing ( <0.001). The significant oversizing group underwent less post-dilatation ( =0.002) but achieved greater stent expansion ( <0.001) and less incomplete stent apposition ( <0.001) without increase of edge dissection after procedure. When stratified by vessel size and stent oversizing, progressive decreases of restenosis ( =0.002) and target lesion revascularization rates ( =0.007) were found in favor of larger vessel size and oversized stents. Stent thrombosis was observed the most in small RVD with low percentage of stent oversizing group among the subgroups ( =0.040). The positive impact of stent oversizing was documented on procedural and clinical outcomes. In particular, small vessels treated with smaller stents were associated with greater adverse events, suggesting that aggressive selection of larger stents, with appropriate attention to edge effects, may optimize long-term outcomes, even in drug-eluting stents implantation.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.