Bisschops, Raf; East, James E.; Hassan, Cesare; Hazewinkel, Yark; Kamiński, Michał F.; Neumann, Helmut; Pellisé, Maria; Antonelli, Giulio; Bustamante Balen, Marco; Coron, Emmanuel; Cortas, Georges; Iacucci, Marietta; Yuichi, Mori; Longcroft-Wheaton, Gaius; Pilonis, Nastazja; Puig, Ignasi; van Hooft, Jeanin E.; Dekker, Evelien
Endoscopy, 12/2019, Letnik: 51, Številka: 12Journal Article
Main Recommendations 1 ESGE suggests that high definition endoscopy, and dye or virtual chromoendoscopy, as well as add-on devices, can be used in average risk patients to increase the endoscopist’s adenoma detection rate. However, their routine use must be balanced against costs and practical considerations. Weak recommendation, high quality evidence. 2 ESGE recommends the routine use of high definition systems in individuals with Lynch syndrome. Strong recommendation, high quality evidence. 3 ESGE recommends the routine use, with targeted biopsies, of dye-based pancolonic chromoendoscopy or virtual chromoendoscopy for neoplasia surveillance in patients with long-standing colitis. Strong recommendation, moderate quality evidence. 4 ESGE suggests that virtual chromoendoscopy and dye-based chromoendoscopy can be used, under strictly controlled conditions, for real-time optical diagnosis of diminutive (≤ 5 mm) colorectal polyps and can replace histopathological diagnosis. The optical diagnosis has to be reported using validated scales, must be adequately photodocumented, and can be performed only by experienced endoscopists who are adequately trained, as defined in the ESGE curriculum, and audited. Weak recommendation, high quality evidence. 5 ESGE recommends the use of high definition white-light endoscopy in combination with (virtual) chromoendoscopy to predict the presence and depth of any submucosal invasion in nonpedunculated colorectal polyps prior to any treatment. Strong recommendation, moderate quality evidence. 6 ESGE recommends the use of virtual or dye-based chromoendoscopy in addition to white-light endoscopy for the detection of residual neoplasia at a piecemeal polypectomy scar site. Strong recommendation, moderate quality evidence. 7 ESGE suggests the possible incorporation of computer-aided diagnosis (detection and characterization of lesions) to colonoscopy, if acceptable and reproducible accuracy for colorectal neoplasia is demonstrated in high quality multicenter in vivo clinical studies. Possible significant risks with implementation, specifically endoscopist deskilling and over-reliance on artificial intelligence, unrepresentative training datasets, and hacking, need to be considered. Weak recommendation, low quality evidence.
Avtor
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.