Akademska digitalna zbirka SLovenije - logo
E-viri
Celotno besedilo
Recenzirano
  • Krivda, M; Barnby, L; Bombara, M; Evans, D; Jones, P G; Jusko, A; Kralik, I; Lazzeroni, C; Lietava, R; Matthews, Z L; Navin, S; Kour, R; Palaha, A S; Petrov, PR

    Journal of instrumentation, 01/2012, Letnik: 7
    Journal Article

    The ALICE trigger system installed in the experimental cavern processes information from triggering detectors at 3 hardware levels, and is used in p-p and Pb-Pb collisions. Many automatic functions have been developed to facilitate work in the control room. The hardware is permanently monitored, and around 1200 counters, with considerable built-in redundancy, are read at regular intervals (at least once per minute). This provides relevant physics information and also verifies the consistency of the hardware operation. In order to compensate for seasonal drift, the CORDE module has been installed, which allows the LHC clock to be delayed in steps of 10 ps. This paper describes the current status of the ALICE trigger system after experience with p-p and Pb-Pb runs, the new firmware developments and the appropriate software for this electronics.