  • Continuous monitoring of AP...
    Wahl, P.R.; Pucher, I.; Scheibelhofer, O.; Kerschhaggl, M.; Sacher, S.; Khinast, J.G.

    International journal of pharmaceutics, 02/2017, Letnik: 518, Številka: 1-2
    Journal Article

    Display omitted Near-infrared chemical imaging (NIR-CI) with high-speed cameras based on the push-broom acquisition principle is a rapidly-evolving and can be used for a variety of purposes, from classification (and sorting) of products to mapping spatial distribution of materials. The present study examined if NIR-CI is suitable for tablet manufacturing. To that end, the tablets were introduced into the CI system via a flat belt conveyor. A formulation, which consisted of 4wt.%–6wt.% caffeine, 5wt.% crospovidone as a disintegrant, 88wt.%–90wt.% lactose as a filler and 1wt.% magnesium stearate as a lubricator, was tableted at compression forces ranging from 5kN to 30kN. The intra- and inter-tablet homogeneity of caffeine and the tablet’s hardness were analyzed via NIR‐CI. For the homogeneity evaluation, two methods were applied: standard deviation (SD) and distributional homogeneity index (DHI). The results showed that the SD of caffeine in a single tablet increased with an increase in the caffeine content. This was attributed to natural variations in a binary mixture of caffeine and excipients. Overall, the chosen NIR-CI setup has strong potential to be transferred to the production scale to monitor all tablets in a production stream.