Akchurin, N.; Almeida, P.; Altopp, G.; Alyari, M.; Bergauer, T.; Brondolin, E.; Burkle, B.; Frey, W.D.; Gecse, Z.; Heintz, U.; Hinton, N.; Kuryatkov, V.; Lipton, R.; Mannelli, M.; Mengke, T.; Paulitsch, P.; Peltola, T.; Pitters, F.; Sicking, E.; Spencer, E.; Tripathi, M.; Pinto, M.V. Barreto; Voelker, J.; Wang, Z.; Yohay, R.
Journal of instrumentation, 09/2020, Letnik: 15, Številka: 9Journal Article
The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-μm-thick silicon (Si) pad sensors as the main active material and will sustain 1 MeV neutron equivalent fluences up to about 1016neqcm−2. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at −30ˆC to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at −30ˆC. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60% or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90% at the lowest fluence, at 600 V. The collected charge close to the fluence of 1016neqcm−2 exceeds 1 fC at voltages beyond 800 V.
Avtor
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.