E-viri
Recenzirano
Odprti dostop
-
Grimaldi, Massimo; Quadrini, Federico; Caporusso, Nicola; Troisi, Federica; Vitulano, Nicola; Delmonte, Vito; Di Monaco, Antonio
Europace (London, England), 08/2023, Letnik: 25, Številka: 9Journal Article
Abstract Background Pulsed field ablation (PFA) is a novel, largely nonthermal ablative modality that, by virtue of its putative preferential action on myocardial tissue through the process of irreversible electroporation (IRE), may replace conventional thermal ablation for atrial fibrillation (AF). The recent inspIRE study confirmed safety and effectiveness of a fully integrated biphasic PFA system with a variable loop circular catheter for the treatment of paroxysmal AF. The majority of PFA procedures were performed using general anesthesia. However, due to the risks of general anesthesia we report the data regarding our sedation protocol used during inspIRE study. Methods A total of 29 patients (mean age 55±9 years; 72% male) were enrolled as part of this analysis within the inspIRE trial. The sedation protocol is reported in the manuscript. The Richmond Agitation-Sedation Scale (RASS), the Visual Analogue Scale (VAS) and the Patient State Index were collected during sedation. Each patient was monitored using the Masimo Sedline. At the end of ablation, the Likert Scale Questionnaire (LSQ) was used to assess the patients' satisfaction with intraoperative analgesia-sedation. Results No procedural complications were documented. Sufficient oxygen saturation was maintained in all patients during procedure. Non-invasive ventilation or tracheal intubation were not required for any patient. The RAAS score between -1 to -5 was obtained in 27 patients (93%) while the value 0 was obtained in 2 patients (7%). The VAS score between 0 to 2 was obtained in 24 patients (83%); the VAS score 3 in 3 patients (10%) and the VAS score 4 in 2 patients (7%). The PSI score <50 was achieved in 16 patients (55%) while the PSI between 50 and 70 was achieved in 9 patients (31%). Positive answers to LSQ were obtained in most patients. Conclusion During PFA ablation procedures with the variable-loop circular catheter and its accompanying biphasic pulse, our deep sedation protocol is a valid alternative to general anesthesia. Graphical Abstract Graphical abstract
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.