Lacey, Jean M; Minutti, Carla Z; Magera, Mark J; Tauscher, Angela L; Casetta, Bruno; McCann, Mark; Lymp, James; Hahn, Si Houn; Rinaldo, Piero; Matern, Dietrich
Clinical chemistry (Baltimore, Md.), 03/2004, Letnik: 50, Številka: 3Journal Article
Newborn screening for congenital adrenal hyperplasia (CAH) involves measurement of 17alpha-hydroxyprogesterone (17-OHP), usually by immunoassay. Because this testing has been characterized by high false-positive rates, we developed a steroid profiling method that uses liquid chromatography-tandem mass spectrometry (LC-MS/MS) to measure 17-OHP, androstenedione, and cortisol simultaneously in blood spots. Whole blood was eluted from a 4.8-mm (3/16-inch) dried-blood spot by an aqueous solution containing the deuterium-labeled internal standard d(8)-17-OHP. 17-OHP, androstenedione, and cortisol were extracted into diethyl ether, which was subsequently evaporated and the residue dissolved in LC mobile phase. This extract was injected into a LC-MS/MS equipped with pneumatically assisted electrospray. The steroids were quantified in the selected-reaction monitoring mode by use of peak areas in reference to the stable-isotope-labeled internal standard. We analyzed 857 newborn blood spots, including 14 blood spots of confirmed CAH cases and 101 of false-positive cases by conventional screening. Intra- and interassay CVs for 17-OHP were 7.2-20% and 3.9-18%, respectively, at concentrations of 2, 30, and 50 microg/L. At a cutoff for 17-OHP of 12.5 microg/L and a cutoff of 3.75 for the sum of peak areas for 17-OHP and androstenedione divided by the peak area for cortisol, 86 of the 101 false-positive samples were within reference values by LC-MS/MS, whereas the 742 normal and 14 true-positive results obtained by conventional screening were correctly classified. Steroid profiling in blood spots can identify false-positive results obtained by conventional newborn screening for CAH.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.