E-viri
Recenzirano
-
Dian Utami Kartini, Ni Kadek; Listyendah Zahra, Nurul Baiti; Sarwono, Ariyanti; Koko Suryawan, I Wayan
Wahana Teknik Sipil: Jurnal Pengembangan Teknik Sipil, 12/2022, Letnik: 27, Številka: 2Journal Article
Deep wells are one of the sources of water to meet the daily needs of the people in Klungkung Regency. The well water still contains high levels of aluminum and color. For this reason, proper processing planning is needed for the characteristics of wells in Klungkung Regency. One of the appropriate process units to use is the Granular Activated Carbon (GAC) adsorbs. The purpose of this study is to find out the details of the unit area and the need for GAC used in treating well water in Klungkung Regency. The land area required for this unit is 3.82 m2, where this area already includes 2 GAC units. The GAC requirement for each unit is 3209.4 kg with a regeneration time of 6.6 months.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.