-
Evaluation of bone-to-implant contact and bone density adjacent to titanium implants using a stereological technique on ground sectionsBalatsouka, Dimitra ; Gotfredsen, Klaus ; Gundersen, Hans Jørgen G.When bone implants have to be examined in situ ground sections are required. Histomorphometric measurements are usually performed on two-dimensional sections, causing biased results when they are ... wrongly extrapolated to 3D without any knowledge of stereology. Unbiased results can only be obtained using stereological principles. The aim of the study was to describe an unbiased design for evaluating bone-to-implant contact (BIC) and peri-implant bone density (BD-i) in three-dimensions. The unbiased design was based on a fixed axis vertical random sampling technique. Three bone-implant blocks were collected from 3 rabbits. Four sections were obtained from each animal using afixed axis vertical random sampling technique. The BIC was estimated by creating a stereological method based on a systematic test line set. The BD-i was estimated using a design based on a systematic point set. The efficiency of the systematic sampling was evaluated for each sampling level: Coefficient of error CE(wi) for the systematic test line set, CESyst between the 4 rotatedsections, CENoise for the reproducibility. These variances were compared to the biological variation (CV) between animals. The mean CE(Wi) was5 to 6%; the CESyst was 7.8% for the BIC estimates and 5.7% for the BD-i estimates; the CENoise was 5.8% for the BIC and 7.7% for the BD-i. The CV was 19% for the BIC estimates and 24% for the BD-i estimates. These results demonstrated that the stereological technique used in the present study was a very efficient method to obtain unbiased estimates of BIC and BD-i in 3D on 2Dimplant-bone sections.Source: Image analysis & stereology : official journal of the International Society for Stereology. - ISSN 1580-3139 (Vol. 25, no. 1, mar. 2006, str. 13-24)Type of material - article, component partPublish date - 2006Language - englishCOBISS.SI-ID - 21169369
Author
Balatsouka, Dimitra |
Gotfredsen, Klaus |
Gundersen, Hans Jørgen G.
Topics
Bone Screws |
Tibia |
Anatomy And Histology |
Titanium |
Osseointegration |
Bone Density |
Rabbits |
Image Processing, Computer-Assisted |
Kost, gostota |
Kostni vijaki |
Oseointegracija |
Tibija |
Titan |
Slika, obdelava z računalnikom |
Zajci |
kosti |
kostna gostota |
implantati |
histologija |
stereologija
![loading ... loading ...](themes/default/img/ajax-loading.gif)
source: Image analysis & stereology : official journal of the International Society for Stereology. - ISSN 1580-3139 (Vol. 25, no. 1, mar. 2006, str. 13-24)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Balatsouka, Dimitra | ![]() |
Gotfredsen, Klaus | ![]() |
Gundersen, Hans Jørgen G. | ![]() |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
Pickup location | Material status | Reservation |
---|
Please wait a moment.
Naročanje gradiva za izposojo v čitalnice
Naročanje kopij člankov
Urnik dostave gradiva z oznako DS v signaturi