  • Setting times measurements of portland cements with pulsed USWR method = Merjenje časov vezanja portland cementov s pulzno USWR metodo
    Valič, Marko ...
    In this paper we present the results of parallel measurements on PC cements; the setting times with a standard Vicat apparatus and the reflection coefficient changes ▫$\Delta$▫r during early ... hydration with a pulsed ultrasonic shear wave reflection (USWR) hardening meter. The measurements were carried out on the same samples and under the same ambient conditions. In contrast to the Vicat needle test, the USWR method gives continuous information on the stiffening and hardening process over time via ▫$\Delta$▫r changes, as the rigidity of the pastes grow on hydration. The magnitudes of the ▫$\Delta$▫r change in selected cement pastes (CEM I 52.5R and PC 30dz 45s) at Vicat setting times are used to determine the correlation between the two methods. Through such calibration the setting times of production samples can be satisfactorily measured with the USWR method.
    Source: Kovine zlitine tehnologije = Metals alloys technologies. - ISSN 1318-0010 (Letn. 32, št. 1/2, jan.-apr. 1999, str. 83-86)
    Type of material - article, component part
    Publish date - 1999
    Language - english
    COBISS.SI-ID - 559715

source: Kovine zlitine tehnologije = Metals alloys technologies. - ISSN 1318-0010 (Letn. 32, št. 1/2, jan.-apr. 1999, str. 83-86)