The measurement of the energy spectrum of cosmic ray helium nuclei from 70 GeV to 80 TeV using 4.5 years of data recorded by the Dark Matter Particle Explorer (DAMPE) is reported in this work. A ...hardening of the spectrum is observed at an energy of about 1.3 TeV, similar to previous observations. In addition, a spectral softening at about 34 TeV is revealed for the first time with large statistics and well controlled systematic uncertainties, with an overall significance of 4.3σ. The DAMPE spectral measurements of both cosmic protons and helium nuclei suggest a particle charge dependent softening energy, although with current uncertainties a dependence on the number of nucleons cannot be ruled out.
Abstract
We report on analysis of observations of the bright transient X-ray pulsar Swift J0243.6+6124 obtained during its 2017-2018 giant outburst with Insight-HXMT, NuSTAR, and Swift observatories. ...We focus on the discovery of a sharp state transition of the timing and spectral properties of the source at super-Eddington accretion rates, which we associate with the transition of the accretion disk to a radiation pressure dominated (RPD) state, the first ever directly observed for magnetized neutron star. This transition occurs at slightly higher luminosity compared to already reported transition of the source from sub- to super-critical accretion regime associate with onset of an accretion column. We argue that this scenario can only be realized for comparatively weakly magnetized neutron star, not dissimilar to other ultra-luminous X-ray pulsars (ULPs), which accrete at similar rates. Further evidence for this conclusion is provided by the non-detection of the transition to the propeller state in quiescence which strongly implies compact magnetosphere and thus rules out magnetar-like fields.
Objective: Subcellular-sized chronically implanted recording electrodes have demonstrated significant improvement in single unit (SU) yield over larger recording probes. Additional work expands on ...this initial success by combining the subcellular fiber-like lattice structures with the design space versatility of silicon microfabrication to further improve the signal-to-noise ratio, density of electrodes, and stability of recorded units over months to years. However, ultrasmall microelectrodes present very high impedance, which must be lowered for SU recordings. While poly(3,4-ethylenedioxythiophene) (PEDOT) doped with polystyrene sulfonate (PSS) coating have demonstrated great success in acute to early-chronic studies for lowering the electrode impedance, concern exists over long-term stability. Here, we demonstrate a new blend of PEDOT doped with carboxyl functionalized multiwalled carbon nanotubes (CNTs), which shows dramatic improvement over the traditional PEDOT/PSS formula. Methods: Lattice style subcellular electrode arrays were fabricated using previously established method. PEDOT was polymerized with carboxylic acid functionalized carbon nanotubes onto high-impedance (8.0 ± 0.1 MΩ: M ± S.E.) 250-μm 2 gold recording sites. Results: PEDOT/CNT-coated subcellular electrodes demonstrated significant improvement in chronic spike recording stability over four months compared to PEDOT/PSS recording sites. Conclusion: These results demonstrate great promise for subcellular-sized recording and stimulation electrodes and long-term stability. Significance: This project uses leading-edge biomaterials to develop chronic neural probes that are small (subcellular) with excellent electrical properties for stable long-term recordings. High-density ultrasmall electrodes combined with advanced electrode surface modification are likely to make significant contributions to the development of long-term (permanent), high quality, and selective neural interfaces.
This study aimed to explore the effect and mechanism of chondrocyte apoptosis on the chemotaxis of osteoclast precursors (OCPs) during bone destruction.
The relationship between cartilage and bone ...destruction was verified with a rat temporomandibular joint osteoarthritis (TMJOA) model. The pan-caspase inhibitor Z-VAD-FMK (ZVAD) was applied to confirm the chemotactic effect of chondrocyte apoptosis on OCPs. Synthesis and release of the key chemokine CX3CL1 in apoptotic and non-apoptotic chondrocytes was assessed with IHC, IF, WB, and ELISA. The function of CX3CL1-CX3CR1 axis in the chemotaxis of OCPs was examined by CX3XR1 inhibitor AZD8797 (AZD) and si-CX3CL1. The regulatory effect of p38 MAPK on CX3CL1 release was verified by p38 inhibitor PH-797804.
A temporal and spatial association between cartilage degradation and bone resorption was found in the TMJOA model. The caspase-dependent chondrocyte apoptosis promoted chemotaxis of OCPs, which can be restrained by ZVAD. CX3CL1 was significantly upregulated when chondrocytes underwent apoptosis, and it played a critical role in the recruitment of OCPs, blockage of CX3CL1-CX3CR1 axis resulted in less bone resorption in TMJOA. P38 MAPK was activated in apoptotic chondrocytes, and had a regulatory effect on the synthesis and release of CX3CL1. After inhibition of p38 by PH-797804, the chemotactic effect of apoptotic chondrocytes on OCPs was limited.
This study indicates that apoptosis of chondrocytes in TMJOA enhances chemotaxis of OCPs toward osteoclast precursors through upregulation of the p38-CX3CL1 axis, thereby promoting the activation of local osteoclasts.
The natural resonance appears at 16
GHz for (Fe, Ni)/C nanocapsules with (Fe, Ni) alloys as cores and graphite as shells. Reflection loss (RL) exceeding −10
dB was obtained in the whole Ku-band ...(12.4–18
GHz) for an absorber thickness of 2.0
mm, while it exceeds −20
dB over the 13.6–16.6
GHz range. In addition, the bandwidth does not change dramatically for the thicknesses of 1.87–2.1
mm for the RL values exceeding −10
dB. The (Fe, Ni)/C nanocapsules with wide bandwidth absorption can be used as excellent electromagnetic-wave-absorption materials in the whole Ku-band.
Abstract Penetrating intracortical electrode arrays that record brain activity longitudinally are powerful tools for basic neuroscience research and emerging clinical applications. However, ...regardless of the technology used, signals recorded by these electrodes degrade over time. The failure mechanisms of these electrodes are understood to be a complex combination of the biological reactive tissue response and material failure of the device over time. While mechanical mismatch between the brain tissue and implanted neural electrodes have been studied as a source of chronic inflammation and performance degradation, the electrode failure caused by mechanical mismatch between different material properties and different structural components within a device have remained poorly characterized. Using Finite Element Model (FEM) we simulate the mechanical strain on a planar silicon electrode. The results presented here demonstrate that mechanical mismatch between iridium and silicon leads to concentrated strain along the border of the two materials. This strain is further focused on small protrusions such as the electrical traces in planar silicon electrodes. These findings are confirmed with chronic in vivo data (133–189 days) in mice by correlating a combination of single-unit electrophysiology, evoked multi-unit recordings, electrochemical impedance spectroscopy, and scanning electron microscopy from traces and electrode sites with our modeling data. Several modes of mechanical failure of chronically implanted planar silicon electrodes are found that result in degradation and/or loss of recording. These findings highlight the importance of strains and material properties of various subcomponents within an electrode array.
Implantable biosensors are valuable scientific tools for basic neuroscience research and clinical applications. Neurotechnologies provide direct readouts of neurological signal and neurochemical ...processes. These tools are generally most valuable when performance capacities extend over months and years to facilitate the study of memory, plasticity, and behavior or to monitor patients’ conditions. These needs have generated a variety of device designs from microelectrodes for fast scan cyclic voltammetry (FSCV) and electrophysiology to microdialysis probes for sampling and detecting various neurochemicals. Regardless of the technology used, the breaching of the blood–brain barrier (BBB) to insert devices triggers a cascade of biochemical pathways resulting in complex molecular and cellular responses to implanted devices. Molecular and cellular changes in the microenvironment surrounding an implant include the introduction of mechanical strain, activation of glial cells, loss of perfusion, secondary metabolic injury, and neuronal degeneration. Changes to the tissue microenvironment surrounding the device can dramatically impact electrochemical and electrophysiological signal sensitivity and stability over time. This review summarizes the magnitude, variability, and time course of the dynamic molecular and cellular level neural tissue responses induced by state-of-the-art implantable devices. Studies show that insertion injuries and foreign body response can impact signal quality across all implanted central nervous system (CNS) sensors to varying degrees over both acute (seconds to minutes) and chronic periods (weeks to months). Understanding the underlying biological processes behind the brain tissue response to the devices at the cellular and molecular level leads to a variety of intervention strategies for improving signal sensitivity and longevity.
Hydrodynamic characteristics of hydrofoils with leading-edge tubercles were experimentally investigated in a water tunnel at a Reynolds number of Re=1.4×104. Particle image velocimetry measurements ...and particle-streak visualizations reveal that the tubercles improve flow separation behaviour. In particular, hydrofoils with larger wave amplitudes and smaller wavelengths tend to perform significantly better in flow separation control. Cross-stream flow measurements indicate that streamwise counter-rotating vortex pairs are generated over the tubercles and mitigate flow separation. Analysis confirms that the tubercles function as vortex generators, due to their comparable heights relative to the boundary layer thickness. The vortex pairs meander and interact with adjacent flows, causing the flow separation behaviour to be occasionally unstable, thus leading to variable flow separation region sizes. This suggests that measures may have to be taken to ensure the stability of the counter-rotating vortex pairs for more persistent and predictable improvements.
Display omitted
•Leading-edge tubercles could significantly improve flow separation behaviour for hydrofoils.•Streamwise counter-rotating vortex pairs are generated over the tubercles, which mitigate flow separations.•The tubercles behave like the leading-edges of small delta wings and function as vortex generators.•The streamwise counter-rotating vortex pairs generated are not stable.•CVPs meander and interact with neighbouring vortices, which cause the flow separation region to vary in size.
There are limited data comparing the prognosis and fertility outcomes of the patients with early cervical cancer treated by trans-vaginal radical trachelectomy (VRT) or abdominal radical ...trachelectomy (ART).The objective of this study was to compare the surgical and pathologic characteristics, the prognosis and fertility outcomes of the patients treated by VRT or ART.
Matched-case study based on a prospectively maintained database of patients underwent radical trachelectomy in 10 centres of China was designed to compare the prognosis and fertility outcomes of the patients treated by VRT or ART.
Totally 150 cases, 77 in the VRT and 73 in the ART group, were included. VRT and ART provide similar surgical and pathological outcomes except larger specimens obtained by ART. In the ART group, no patient developed recurrent diseases, but, in the VRT group, 7 (9.8%) patients developed recurrent diseases and 2 (1.6%) patients died of the tumours (P=0.035). The rate of pregnancy in the VRT group was significantly higher than those of ART (39.5% vs 8.8%; P=0.003). The patients with tumour size >2 cm showed significant higher recurrent rate (11.6% vs 2.4%, P<0.05) and lower pregnant rate (12.5% vs 32.1%, P=0.094) compared with the patients with tumour size <2 cm.
Patients treated by ART obtained better oncology results, but their fertility outcomes were unfavourable compared with VRT. Tumour size <2 cm should be emphasised as an indication for radical trachelectomy for improving the outcome of fertility and prognosis.
Abstract Implantable neural electrode technologies for chronic neural recordings can restore functional control to paralysis and limb loss victims through brain-machine interfaces. These probes, ...however, have high failure rates partly due to the biological responses to the probe which generates an inflammatory scar and subsequent neuronal cell death. L1 is a neuronal specific cell adhesion molecule and has been shown to minimize glial scar formation and promote electrode-neuron integration when covalently attached to the surface of neural probes. In this work, the acute microglial response to L1-coated neural probes was evaluated in vivo by implanting coated devices into the cortex of mice with fluorescently labeled microglia, and tracking microglial dynamics with multi-photon microscopy for the ensuing 6 h in order to understand L1's cellular mechanisms of action. Microglia became activated immediately after implantation, extending processes towards both L1-coated and uncoated control probes at similar velocities. After the processes made contact with the probes, microglial processes expanded to cover 47.7% of the control probes' surfaces. For L1-coated probes, however, there was a statistically significant 83% reduction in microglial surface coverage. This effect was sustained through the experiment. At 6 h post-implant, the radius of microglia activation was reduced for the L1 probes by 20%, shifting from 130.0 to 103.5 μm with the coating. Microglia as far as 270 μm from the implant site displayed significantly lower morphological characteristics of activation for the L1 group. These results suggest that the L1 surface treatment works in an acute setting by microglial mediated mechanisms.