In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have ...undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted.
Angiographic severity of coronary artery stenosis has historically been the primary guide to revascularization or medical management of coronary artery disease. However, physiologic severity defined ...by coronary pressure and/or flow has resurged into clinical prominence as a potential, fundamental change from anatomically to physiologically guided management. This review addresses clinical coronary physiology—pressure and flow—as clinical tools for treating patients. We clarify the basic concepts that hold true for whatever technology measures coronary physiology directly and reliably, here focusing on positron emission tomography and its interplay with intracoronary measurements.
Objectives This study sought to determine the feasibility of performing a comprehensive cardiac computed tomographic (CT) examination incorporating stress and rest myocardial perfusion imaging ...together with coronary computed tomography angiography (CTA). Background Although cardiac CT can identify coronary stenosis, very little data exist on the ability to detect stress-induced myocardial perfusion defects in humans. Methods Thirty-four patients who had a nuclear stress test and invasive angiography were included in the study. Dual-source computed tomography (DSCT) was performed as follows: 1) stress CT: contrast-enhanced scan during adenosine infusion; 2) rest CT: contrast-enhanced scan using prospective triggering; and 3) delayed scan: acquired 7 min after rest CT. Images for CTA, computed tomography perfusion (CTP), and single-photon emission computed tomography (SPECT) were each read by 2 independent blinded readers. Results The DSCT protocol was successfully completed for 33 of 34 subjects (average age 61.4 ± 10.7 years; 82% male; body mass index 30.4 ± 5 kg/m2 ) with an average radiation dose of 12.7 mSv. On a per-vessel basis, CTP alone had a sensitivity of 79% and a specificity of 80% for the detection of stenosis ≥50%, whereas SPECT myocardial perfusion imaging had a sensitivity of 67% and a specificity of 83%. For the detection of vessels with ≥50% stenosis with a corresponding SPECT perfusion abnormality, CTP had a sensitivity of 93% and a specificity of 74%. The CTA during adenosine infusion had a per-vessel sensitivity of 96%, specificity of 73%, and negative predictive value of 98% for the detection of stenosis ≥70%. Conclusions Adenosine stress CT can identify stress-induced myocardial perfusion defects with diagnostic accuracy comparable to SPECT, with similar radiation dose and with the advantage of providing information on coronary stenosis.
Chronic kidney disease (CKD), defined as dysfunction of the glomerular filtration apparatus, is an independent risk factor for the development of coronary artery disease (CAD). Patients with CKD are ...at a substantially higher risk of cardiovascular mortality compared with the age- and sex-adjusted general population with normal kidney function. The risk of CAD and mortality in patients with CKD is correlated with the degree of renal dysfunction including presence of microalbuminuria. A greater cardiovascular risk, albeit lower than for patients receiving dialysis, persists even after kidney transplantation. Congestive heart failure, commonly caused by CAD, also accounts for a significant portion of the cardiovascular-related events observed in CKD. The optimal strategy for the evaluation of CAD in patients with CKD, particularly before renal transplantation, remains a topic of contention spanning over several decades. Although the evaluation of coexisting cardiac disease in patients with CKD is desirable, severe renal dysfunction limits the use of radiographic and magnetic resonance contrast agents due to concerns regarding contrast-induced nephropathy and nephrogenic systemic sclerosis, respectively. In addition, many patients with CKD have extensive and premature (often medial) calcification disproportionate to the severity of obstructive CAD, thereby limiting the diagnostic value of computed tomography angiography. As such, echocardiography, non–contrast-enhanced magnetic resonance, nuclear myocardial perfusion, and metabolic imaging offer a variety of approaches to assess obstructive CAD and cardiomyopathy of advanced CKD without the need for nephrotoxic contrast agents.
Display omitted
•CKD is associated with increased risk of CAD, and the risk increases with worsening renal function.•Risks of revascularization are increased in patients with CKD, and long-term results are less favorable than those with normal renal function.•Diagnostic imaging studies should be directed toward patients with CKD whose risk of cardiac events is heightened and who are most likely to benefit from revascularization.•There are no compelling reasons to routinely select one particular stress imaging modality in preference to others, although there may be specific circumstances that favor a particular test.•Imaging techniques that require the use of contrast media that can cause contrast-induced nephropathy or nephrogenic systemic sclerosis should be avoided.
Objectives This study tests the hypothesis that absolute measurement of adenosine (Ado)-stimulated myocardial blood flow (MBFado) is superior to measurement of relative tracer uptake for ...identification of hemodynamically significant coronary artery disease (CAD). Background Positron emission tomography measurement of absolute myocardial blood flow (MBF) (13 N-ammonia) with Ado has the capability to more accurately assess hemodynamic severity of CAD than measurement of relative tracer content (TC) (nCi/ml) during Ado, which by definition depends on at least 1 normal zone to which others are compared. Methods A total of 27 patients (20 male, 58 ± 11 years, mean ± SD) with known or suspected CAD and 21 normal subjects (13 male, 38 ± 10 years) were studied. Parametric (K1) MBF images and TC sum images were analyzed. A stenosis ≥70% defined significant CAD. The receiver-operator characteristic curve (ROC) analysis area under the curve (AUC) compared MBF and TC results. Cut-point analysis for sensitivity, specificity, and accuracy showed the best MBF criteria for CAD as MBFado <1.85 ml/min/g and the best TC as <70% maximum. The myocardial blood flow reserve ratio (MBFR) (optimal <2.0×) also was studied. Results The ROC analysis of PET parameters showed that MBFado was superior to <70% maximum uptake for CAD detection (n = 144 vessels; AUC 0.900 vs. 0.690, respectively, p < 0.0001) and was marginally greater than MBFR (0.856; p = 0.10). For CAD cut-point analysis, MBFado accuracy exceeded TC (0.84 vs. 0.72, respectively, p = 0.005), as did sensitivity (0.81 vs. 0.48, respectively; p = 0.001). Specificity of MBFado for CAD classification (0.85) was comparable to TC (0.82; p = NS). Sensitivity, specificity, and predictive accuracy for MBFR were 0.62, 0.85, and 0.79, respectively. The difference in specificity was not significant versus MBFado. However, MBFado was more sensitive than MBFR (p = 0.01). The difference in predictive accuracy was borderline (p = 0.06) in favor of MBFado. Conclusions Measurement of Ado-stimulated absolute MBF is superior to relative measurement of myocardial tracer retention for identification of CAD and can be accomplished with a single MBFado measurement.