ABSTRACT
High time resolution and accuracy are of critical importance in the studies of timing analysis and time delay localization of gamma-ray bursts (GRBs), soft gamma-ray repeaters (SGRs) and ...pulsars. The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) consisting of two micro-satellites, GECAM-A and GECAM-B, launched on 2020 December 10, is aimed at monitoring and locating X-ray and GRBs all over the sky. To achieve its scientific goals, GECAM is designed to have the highest time resolution (0.1 $\mu {\rm s}$) among all GRB detectors ever flown. Here, we make a comprehensive time calibration campaign including both on-ground and on-orbit tests to derive not only the relative time accuracy of GECAM satellites and detectors, but also the absolute time accuracy of GECAM-B. Using the on-ground calibration with a $\rm ^{22}Na$ radioactive source, we find that the relative time accuracy between GECAM-A and GECAM-B is about 0.15 $\mu {\rm s}$ (1σ). To measure the relative time accuracy between all detectors of a single GECAM satellite, cosmic-ray events detected on orbit are utilized since they could produce many secondary particles simultaneously record by multiple detectors. We find that the relative time accuracy among all detectors onboard GECAM-B is about 0.12 $\mu {\rm s}$ (1σ). Finally, we use the novel Li-CCF method to perform the absolute time calibration with Crab pulsar and SGR J1935+2154, both of which were jointly observed by GECAM-B and Fermi/GBM, and obtain that the time difference between GECAM-B and Fermi/GBM is 3.06 ± 6.04 $\mu {\rm s}$ (1σ).
We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses (mχ) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on ...time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg day exposure and 250 eVee threshold for AM analysis. The sensitive windows in mχ are expanded by an order of magnitude to lower DM masses with Migdal effect incorporated. New limits on σχNSI at 90% confidence level are derived as 2×10−32∼7×10−35 cm2 for TI analysis at mχ∼50–180 MeV/c2, and 3×10−32∼9×10−38 cm2 for AM analysis at mχ∼75 MeV/c2–3.0 GeV/c2.
The extension of the cosmic-ray spectrum beyond 1 petaelectronvolt (PeV; 10
electronvolts) indicates the existence of the so-called PeVatrons-cosmic-ray factories that accelerate particles to PeV ...energies. We need to locate and identify such objects to find the origin of Galactic cosmic rays
. The principal signature of both electron and proton PeVatrons is ultrahigh-energy (exceeding 100 TeV) γ radiation. Evidence of the presence of a proton PeVatron has been found in the Galactic Centre, according to the detection of a hard-spectrum radiation extending to 0.04 PeV (ref.
). Although γ-rays with energies slightly higher than 0.1 PeV have been reported from a few objects in the Galactic plane
, unbiased identification and in-depth exploration of PeVatrons requires detection of γ-rays with energies well above 0.1 PeV. Here we report the detection of more than 530 photons at energies above 100 teraelectronvolts and up to 1.4 PeV from 12 ultrahigh-energy γ-ray sources with a statistical significance greater than seven standard deviations. Despite having several potential counterparts in their proximity, including pulsar wind nebulae, supernova remnants and star-forming regions, the PeVatrons responsible for the ultrahigh-energy γ-rays have not yet been firmly localized and identified (except for the Crab Nebula), leaving open the origin of these extreme accelerators.
We present improved germanium-based constraints on sub-GeV dark matter via dark matter-electron (χ-e) scattering using the 205.4 kg·day dataset from the CDEX-10 experiment. Using a novel calculation ...technique, we attain predicted χ-e scattering spectra observable in high-purity germanium detectors. In the heavy mediator scenario, our results achieve 3 orders of magnitude of improvement for m_{χ} larger than 80 MeV/c^{2} compared to previous germanium-based χ-e results. We also present the most stringent χ-e cross-section limit to date among experiments using solid-state detectors for m_{χ} larger than 90 MeV/c^{2} with heavy mediators and m_{χ} larger than 100 MeV/c^{2} with electric dipole coupling. The result proves the feasibility and demonstrates the vast potential of a new χ-e detection method with high-purity germanium detectors in ultralow radioactive background.
Fast radio bursts (FRBs) are millisecond-duration radio transients
of unknown origin. Two possible mechanisms that could generate extremely coherent emission from FRBs invoke neutron star ...magnetospheres
or relativistic shocks far from the central energy source
. Detailed polarization observations may help us to understand the emission mechanism. However, the available FRB polarization data have been perplexing, because they show a host of polarimetric properties, including either a constant polarization angle during each burst for some repeaters
or variable polarization angles in some other apparently one-off events
. Here we report observations of 15 bursts from FRB 180301 and find various polarization angle swings in seven of them. The diversity of the polarization angle features of these bursts is consistent with a magnetospheric origin of the radio emission, and disfavours the radiation models invoking relativistic shocks.
The prevalence of diabetes in China is among the highest in the world. For this reason, findings from the 2016 Global Burden of Disease (GBD) study were used to calculate the burden of hyperglycaemia ...and diabetes in China.
Following the general analytical strategy used in GBD 2016, diabetes prevalence and mortality were analyzed by age and gender. Trends in disability-adjusted life years (DALYs) due to diabetes were assessed in 33 province-level administrative units from 1990 to 2016, and similar data were provided for chronic kidney disease (CKD) related to diabetes and, as an overall summarizing measure, for hyperglycaemia expressed as high fasting plasma glucose (HFPG).
From 1990 to 2016, all-age prevalence of diabetes rose from 3.7% to 6.6%, and all-age diabetes and diabetes-related CKD mortality rates increased by 63.5% and 33.3%, respectively, with both rates increasing more rapidly in diabetes patients aged 15–49 years than in any other age groups. In 2016, HFPG became China's sixth leading cause of DALYs, and the attributable DALYs burden was 1802.3/100,000 population. Although the number of diabetes DALYs increased by 95% from 1990 to 2016, age-standardized diabetes DALYs rates increased by only 2.3%. Also, from 1990 to 2016, rates of age-standardized DALYs due to diabetes decreased in 14 provinces, but increased in 19 provinces. High BMI Scores and diets low in whole grains, nuts and seeds were the most important risk factors for diabetes in 2016.
Diabetes and hyperglycaemia constitute a huge health burden in China. The substantial increase in diabetes-related burden represents an ongoing challenge, given the rapidly ageing Chinese population. Thus, a targeted control and preventative strategy needs to be developed at risk factor level to reduce this burden.
With the aim of gathering temporal trends on bacterial epidemiology and resistance from multiple laboratories in China, the CHINET surveillance system was organized in 2005. Antimicrobial ...susceptibility testing was carried out according to a unified protocol using the Kirby-Bauer method or automated systems. Results were analyzed according to Clinical and Laboratory Standards Institute (CLSI) 2014 definitions. Between 2005 and 2014, the number of bacterial isolates ranged between 22 774 and 84 572 annually. Rates of extended-spectrum β-lactamase production among Escherichia coli isolates were stable, between 51.7 and 55.8%. Resistance of E. coli and Klebsiella pneumoniae to amikacin, ciprofloxacin, piperacillin/tazobactam and cefoperazone/sulbactam decreased with time. Carbapenem resistance among K. pneumoniae isolates increased from 2.4 to 13.4%. Resistance of Pseudomonas aeruginosa strains against all of antimicrobial agents tested including imipenem and meropenem decreased with time. On the contrary, resistance of Acinetobacter baumannii strains to carbapenems increased from 31 to 66.7%. A marked decrease of methicillin resistance from 69% in 2005 to 44.6% in 2014 was observed for Staphylococcus aureus. Carbapenem resistance rates in K. pneumoniae and A. baumannii in China are high. Our results indicate the importance of bacterial surveillance studies.