Nowadays detection of deterioration of electrical motors is an important topic of research. Vibration signals often carry diagnostic information of a motor. The authors proposed a setup for the ...analysis of vibration signals of three-phase induction motors. In this paper rotor fault diagnostic techniques of a three-phase induction motor (TPIM) were presented. The presented techniques used vibration signals and signal processing methods. The authors analyzed the recognition rate of vibration signal readings for 3 states of the TPIM: healthy TPIM, TPIM with 1 broken bar, and TPIM with 2 broken bars. In this paper the authors described a method of the feature extraction of vibration signals Method of Selection of Amplitudes of Frequencies – MSAF-12. Feature vectors were obtained using FFT, MSAF-12, and mean of vector sum. Three methods of classification were used: Nearest Neighbor (NN), Linear Discriminant Analysis (LDA), and Linear Support Vector Machine (LSVM). The obtained results of analyzed classifiers were in the range of 97.61 % – 100 %.
The aim of this study was to perform precision measurements of the frequency-temperature dependences of the loss angle tangent of the liquid-solid composite with the FDS Dirana meter. The composite ...consisted of heavily moistered oil-impregnated pressboard. The moisturization of the pressboard occurred in a manner as close as possible to the process of wetting the insulation in power transformers to a moisture content of (5.0 ± 0.2) wt. %. This value of moisture content was chosen because exceeding this value can lead to transformer failure. The measuring temperature range was from 293.15 K (20 °C) to 333.15 K (60 °C), with a step of 8 K. The measuring frequency range was 0.0001 Hz to 5000 Hz. It was observed that the shape of the frequency dependence of the loss angle tangent for a moisture content of 5.0 wt. % does not depend on the value of the measuring temperature. An increase in temperature leads to a shift of the waveforms into the higher frequency region. This is associated with a decrease in the relaxation time, and its value depends on the activation energy. It was found that a good fit of the waveforms, simulated by Dirana, to the actual tgδ waveforms obtained at temperatures between 293.15 K (20 °C) and 333.15 K (60 °C) requires the introduction of temperatures, higher than the actual insulation temperatures, into the program. It was found that estimating the moisture content for different temperatures using Dirana soft-ware for insulating an oil-impregnated pressboard produced large discrepancies from the actual content. Better results were obtained after an adjustment requiring manual temperature correction towards higher, compared to measured, temperatures. The moisture content estimated after correction by the Dirana meter ranges from of 4.5 wt. % to 5.7 wt. % and increases almost linearly with increasing measuring temperature. The average moisture content estimated by the Dirana meter for all measuring temperatures is 5.1 wt. % and is close to the actual content (5.0 ± 0.2) wt. %. The uncertainty of the estimate is ±0.43 wt. % and is more than twice as high as the true value.
The authors describe experimental and theoretical analyses of faults of power transformer winding. Faults were caused by mechanical effect of short-circuit currents. Measurements of transformer were ...carried out in high-voltage laboratory. Frequency and time diagnostic methods (method SFRA - Sweep Frequency Response Analysis, impact test) were used for the analyses. Coils of transformer windings were diagnosed by means of the SFRA method and the time impact test. The analyzed methods had a significant sensitivity to a relatively small deformation of coil. In the analysis a new technique for analyzing the effects of short-circuit currents is introduced. This technique is developed for high-voltage transformers (different types of power). The proposed analyses show that it is necessary to analyze the value of short-circuit current. Short-circuit current represents a danger for the operation of the power transformer. The proposed approach can be used for other types of transformers. Moreover, the presented techniques have a potential application for fault diagnosis of electrical equipment such as: transformers and electrical machines.
The article describes the non-contact and contact analysis of 1-MVA dry power transformers with epoxy-resin insulation using an acoustic camera and frequency analyzer with automatic sweeping for ...low-middle frequency areas. Power transformers are most commonly used for construction component (core, windings, taps) analysis. The electrical, non-rotating machine generates electromagnetic and acoustic emissions that can be used to analyze dry transformers during their operation. Non-contact online diagnostic methods have many advantages over offline methods because it is not necessary to shut down the transformer, and also, the condition and behaviour of the machine are analyzed during its normal operation. The article presents the analysis and comparison of structural parts of the distribution dry transformers of the same type and power. The problem of insufficient or incorrect clamp-screw connection was identified using the SFRA (Sweep Frequency Response Analysis) method.
The paper presents experimental diagnostics of the oil-paper insulating system of power transformers using progressive frequency method. The first part of the paper deals with the basic information ...about diagnostics of power oil transformers. The second part of the paper deals with the use of frequency domain spectroscopy (FDS) for power oil transformers. This method is used in the analysis of insulating condition of power transformer with the system of oil-paper. It was found that the results of these tests are highly influenced by the operating temperature during the experimental measurement. Moisture and conductivity between the insulating transformer paper and oil in an insulating system are highly dependent on the temperature. In the other part, the paper presents experimental results of the diagnostic measurement for a real traction oil transformer at different operating temperatures and states (with oil and without). Finally, the paper presents comparative measurement among several autotransformers with the same power. In experimental measurements, the correlation between the measured values and the operational aspects of the individual oil autotransformers are shown.
Abstract The article presents a theoretical analysis of electromagnetic compatibility (EMC) and experimental measurement of effects of radiation and acoustic emission of high-voltage transformers for ...electronic equipment and working personnel in a control room. Electromagnetic compatibility and safety of equipment are not considered as two distinct areas of study in electric and electronic safety. Economic criteria cannot compromise safety but at the same time immunity levels must be relevant in order to establish a “Functional Safety”. Introducing Special Immunity Levels in the level of equipment testing allows us to combine the two areas of EMC and safety. The measurement was carried out in high-current of very high-voltage distribution station. A real-life analysis of effects of electric and electromagnetic field was carried out. FFT was used for mathematical processing of data which were later presented in a graphical form of a spectrally analyzed area. In the last part of the paper we discuss the suitability of acoustic camera to perform contactless monitoring of the health and operation conditions of the power transformer by analyzing acoustic field generated by the transformer core and windings in near control room.
The paper presents theoretical and experimental analyses of a possible effect of the short-circuit forces on the transformer winding. The first part of the paper is focused on creation and activity ...of the radial and axial forces during a short circuit. It shows dimensions, direction and − of course − the resulting mechanical stress. The presented equation shows basic dependencies of these mechanical forces created in the transformer winding. Finally, the paper presents experimental methods of diagnosing and analysing the effects of short-circuit forces on the transformer winding.
The paper deals with the issue of constructing delay lines on the basis of surface acoustic waves and their application to single-mode oscillators. As a result of a theoretical analysis concrete ...delay lines are proposed.
In the contribution, there is presented a theory of designing a symmetrical mismatched and matched delay line for a single-mode oscillator of electrical signals on the basis of which there were designed and fabricated acoustic-electronic components for sensors of non-electrical quantities.
From the experimental results it can be stated that all of six designed and fabricated delay lines can be effectively used in the construction of single-mode oscillators.
The paper presents mathematical model - TOPSIS method, which was utilized on insulating state of distribution transformer to analyze and sensibility of individual measurements methods mutual ...comparison. We can uniquely determine the importance of these measurements methods with this mathematical apparatus in these measurements methods in insulating state of transformers.
In the paper is presented experimental analysis and diagnostics of insulating system oil-paper for traction transformer by frequency method. In the first part of the paper is described base theory ...about measurement and diagnostics insulating part (oil and paper) of transformers. In the other part of the paper is presented experimental results of the diagnostic measurement for the traction transformer at constant temperature using to diagnostic method - frequency domain spectroscopy (FDS). This method is used for analysis insulating condition of high-voltage equipment with insulating oil-paper. According to follow analysis was compared quality of paper moisture and oil conductivity of transformer - before and after its drying.