Tricuspid regurgitation is a prevalent disease associated with high morbidity and mortality, with few treatment options. The aim of the TRILUMINATE trial is to evaluate the safety and effectiveness ...of TriClip, a minimally invasive transcatheter tricuspid valve repair system, for reducing tricuspid regurgitation.
The TRILUMINATE trial is a prospective, multicentre, single-arm study in 21 sites in Europe and the USA. Patients with moderate or greater triscuspid regurgitation, New York Heart Association class II or higher, and who were adequately treated per applicable standards were eligible for enrolment. Patients were excluded if they had systolic pulmonary artery pressure of more than 60 mm Hg, a previous tricuspid valve procedure, or a cardiovascular implantable electronic device that would inhibit TriClip placement. Participants were treated using a clip-based edge-to-edge repair technique with the TriClip tricuspid valve repair system. Tricuspid regurgitation was graded using a five-class grading scheme (mild, moderate, severe, massive, and torrential) that expanded on the standard American Society of Echocardiography grading scheme. The primary efficacy endpoint was a reduction in tricuspid regurgitation severity by at least one grade at 30 days post procedure, with a performance goal of 35%, analysed in all patients who had an attempted tricuspid valve repair procedure upon femoral vein puncture. The primary safety endpoint was a composite of major adverse events at 6 months, with a performance goal of 39%. Patients were excluded from the primary safety analysis if they did not reach 6-month follow-up and did not have a major adverse event during previous follow-ups. The trial has completed enrolment and follow-up is ongoing; it is registered with ClinicalTrials.gov, number NCT03227757.
Between Aug 1, 2017, and Nov 29, 2018, 85 patients (mean age 77·8 years SD 7·9; 56 66% women) were enrolled and underwent successful TriClip implantation. Tricuspid regurgitation severity was reduced by at least one grade at 30 days in 71 (86%) of 83 patients who had available echocardiogram data and imaging. The one-sided lower 97·5% confidence limit was 76%, which was greater than the prespecified performance goal of 35% (p<0·0001). One patient withdrew before 6-month follow-up without having had a major adverse event and was excluded from analysis of the primary safety endpoint. At 6 months, five (6%) of 84 patients experienced a major adverse event, which was less than the prespecified performance goal of 39% (p<0·0001). Single leaflet attachment occurred in five (7%) of 72 patients. No periprocedural deaths, conversions to surgery, device embolisations, or strokes occurred. At 6 months, all-cause mortality had occurred in four (5%) of 84 patients.
The TriClip system appears to be safe and effective at reducing tricuspid regurgitation by at least one grade. This reduction could translate to significant clinical improvement at 6 months post procedure.
Abbott.
Transcatheter aortic valve replacement for treatment of aortic stenosis has now become an accepted alternative to surgical valve replacement for some patients. In addition, transcatheter mitral valve ...repair is also routinely used in high surgical risk patients with mitral regurgitation. Other transcatheter procedures are in rapid development. The current review attempts to summarize the procedures and echocardiographic imaging used for transcatheter valve replacement or valve repair.
Abstract
Aims
The Valve Academic Research Consortium (VARC), founded in 2010, was intended to (i) identify appropriate clinical endpoints and (ii) standardize definitions of these endpoints for ...transcatheter and surgical aortic valve clinical trials. Rapid evolution of the field, including the emergence of new complications, expanding clinical indications, and novel therapy strategies have mandated further refinement and expansion of these definitions to ensure clinical relevance. This document provides an update of the most appropriate clinical endpoint definitions to be used in the conduct of transcatheter and surgical aortic valve clinical research.
Methods and results
Several years after the publication of the VARC-2 manuscript, an in-person meeting was held involving over 50 independent clinical experts representing several professional societies, academic research organizations, the US Food and Drug Administration (FDA), and industry representatives to (i) evaluate utilization of VARC endpoint definitions in clinical research, (ii) discuss the scope of this focused update, and (iii) review and revise specific clinical endpoint definitions. A writing committee of independent experts was convened and subsequently met to further address outstanding issues. There were ongoing discussions with FDA and many experts to develop a new classification schema for bioprosthetic valve dysfunction and failure. Overall, this multi-disciplinary process has resulted in important recommendations for data reporting, clinical research methods, and updated endpoint definitions. New definitions or modifications of existing definitions are being proposed for repeat hospitalizations, access site-related complications, bleeding events, conduction disturbances, cardiac structural complications, and bioprosthetic valve dysfunction and failure (including valve leaflet thickening and thrombosis). A more granular 5-class grading scheme for paravalvular regurgitation (PVR) is being proposed to help refine the assessment of PVR. Finally, more specific recommendations on quality-of-life assessments have been included, which have been targeted to specific clinical study designs.
Conclusions
Acknowledging the dynamic and evolving nature of less-invasive aortic valve therapies, further refinements of clinical research processes are required. The adoption of these updated and newly proposed VARC-3 endpoints and definitions will ensure homogenous event reporting, accurate adjudication, and appropriate comparisons of clinical research studies involving devices and new therapeutic strategies.
Graphical Abstract