The role of serologic testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), in both the clinical and public health settings, will continue to evolve as we gain increasing insight ...into our immune response to the virus. Here, we evaluated four high-throughput serologic tests for detection of anti-SARS-CoV-2 IgG antibodies, from Abbott Laboratories (Abbott Park, IL), Epitope Diagnostics, Inc. (San Diego, CA), Euroimmun (Lubeck, Germany), and Ortho-Clinical Diagnostics (Rochester, NY), using a panel of serially collected serum samples (
= 224) from 56 patients with confirmed coronavirus disease 2019 (COVID-19), healthy donor sera from 2018, and a cross-reactivity serum panel collected in early 2020. The sensitivities of the Abbott, Epitope, Euroimmun, and Ortho-Clinical IgG assays in convalescent-phase serum samples collected more than 14 days post-symptom onset or post-initial positive reverse transcriptase PCR (RT-PCR) result were 92.9% (78/84), 88.1% (74/84), 97.6% (82/84), and 98.8% (83/84), respectively. Among unique convalescent patients, sensitivities of the Abbott, Epitope, Euroimmun, and Ortho-Clinical anti-SARS-CoV-2 IgG assays were 97.3% (36/37), 73% (27/37), 94.6% (35/37), and 97.3% (36/37), respectively. Overall assay specificity/positive predictive values based on a 5% prevalence rate were 99.6%/92.8%, 99.6%/90.6%, 98.0%/71.2%, and 99.6%/92.5%, respectively, for the Abbott, Epitope, Euroimmun, and Ortho-Clinical IgG assays. In conclusion, we show high sensitivity in convalescent-phase sera and high specificity for the Abbott, Euroimmun, and Ortho-Clinical anti-SARS-CoV-2 IgG assays. With the unprecedented influx of commercially available serologic tests for detection of antibodies against SARS-CoV-2, it remains imperative that laboratories thoroughly evaluate such assays for accuracy prior to implementation.
The QuantiFERON-TB Gold Plus (QFT-Plus; Qiagen, Germantown, MD) interferon gamma release assay (IGRA) received FDA clearance in 2017 and will replace the prior version of the assay, the QFT-Gold ...In-Tube (QFT-GIT). Here, we compared performances of the QFT-Plus assay and the QFT-GIT version in a diverse patient population, including patients undergoing evaluation for or follow-up of latent tuberculosis infection (LTBI;
= 39) or active TB infection (
= 3), and in health care workers (HCWs;
= 119) at Mayo Clinic (Rochester, MN). Compared to the QFT-GIT, the QFT-Plus assay showed 91.2% (31/34) positive, 98.4% (124/126) negative, and 96.6% (156/161) overall qualitative agreement among the 161 enrolled subjects, with a Cohen's kappa value of 0.91 (excellent interrater agreement). Among the 28 patients diagnosed with LTBI at the time of enrollment, the QFT-GIT and QFT-Plus assays agreed in 24 (85.7%) patients; in all four discordant patients, the positivity of the QFT-GIT or QFT-Plus IGRA was associated with low-level interferon gamma (IFN-γ) reactivity, ranging from 0.36 IU/ml to 0.66 IU/ml. Additionally, we document a high degree of correlation between IFN-γ levels in the QFT-GIT TB antigen tube and each of the two QFT-Plus TB antigen tubes, as well as between the QFT-Plus TB1 and TB2 tubes (Pearson's correlation coefficients
> 0.95). Overall, we show comparable results between the QFT-GIT and QFT-Plus assays in our study population composed of subjects presenting with a diverse spectrum of TB infections. Our findings suggest that the necessary transition to the QFT-Plus assay will be associated with a minimal difference in assay performance characteristics.
Dried blood spots (DBS) are an established specimen type for clinical testing given their low cost, ease of collection and storage, and convenient shipping capabilities through the postal system. ...These attributes are complementary to the expansion of SARS-CoV-2 serologic testing, which may be used to inform community seroprevalence rates.
The Luminex xMAP SARS-CoV-2 Multi-Antigen assay utilizes magnetic beads labeled with three viral antigens (nucleocapsid NC, receptor binding domain RBD, spike S1 subunit) to detect anti-viral IgG-class antibodies, and has Food and Drug Administration (FDA) Emergency Use Authorization (EUA) for use in serum and plasma. This assay was modified for use with DBS and validated against paired sera tested by one of two reference assays: the Roche Diagnostics Elecsys anti-SARS-CoV-2 ECLIA or the Euroimmun anti-SARS-CoV-2 IgG ELISA.
159 paired DBS and serum specimens analyzed using the modified Luminex xMAP assay on DBS and the reference methods on serum showed an overall concordance of 96.9% (154/159). Use of multivariate pattern recognition software (CLIR) for post-analytical interpretation of the Luminex xMAP DBS assay results, instead of manufacturer provided interpretive thresholds, increased overall qualitative result concordance to 99.4% (158/159) between the modified Luminex xMAP DBS and reference results.
Use of DBS for detection of antibodies against SARS-CoV-2 provides comparable results to those obtained using serum. DBS concordance was improved with multivariate pattern recognition software (CLIR). We demonstrate that DBS are a reliable specimen type for SARS-CoV-2 antibody detection using the modified Luminex xMAP assay.
Serologic evaluation for Zika virus (ZIKV) infection currently includes an initial screen using an anti-ZIKV IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) followed by ...supplemental testing of specimens with nonnegative results by a plaque reduction neutralization test (PRNT). We compared the performance characteristics of three ELISAs for the detection of IgM class antibodies to ZIKV, including the Centers for Disease Control and Prevention (CDC) Zika MAC-ELISA, the InBios ZIKV
MAC-ELISA, and the Euroimmun anti-Zika Virus IgM ELISA. Additionally, we present our initial experiences with ZIKV serologic testing from a national reference laboratory perspective. Using both retrospectively and prospectively collected specimens from patients with possible ZIKV infection, we show that the CDC and InBios MAC-ELISAs perform comparably to each other, with positive agreement, negative agreement, and interrater kappa values ranging from 87.5% to 93.1%, 95.7% to 98.5%, and 0.52 to 0.83, respectively. In contrast, comparison of the Euroimmun ZIKV ELISA to either the CDC or InBios MAC-ELISAs resulted in positive agreement, negative agreement, and interrater kappa values ranging from 17.9% to 42.9%, 91.7% to 98.6%, and 0.10 to 0.39, respectively. Among the 19 prospective samples submitted for PRNT, nine were negative, eight specimens had neutralizing antibodies to a flavivirus (unable to be identified), and one sample each was confirmed for ZIKV or dengue virus infection. This study highlights the ongoing challenges associated with serologic diagnosis of ZIKV infection. Although the availability of a commercial serologic test for ZIKV has greatly expanded the national capacity for such testing, the need to further characterize and improve these assays, particularly with regard to specificity, remains.
The COVID-19 pandemic led to development of numerous serologic tests. To obviate the need for phlebotomy services, we validated dried blood spots (DBS) for anti-SARS-CoV-2 serologic testing. ...Immunoglobulins were extracted from 3 mm DBS punches and the extracts were analyzed using the Euroimmun anti-SARS-CoV-2 IgG ELISA. Various pre-analytical factors were studied. Results were favorable for DBS stored for at least 67 days at or below 37°C. Comparison between paired serum and DBS specimens tested by the Euroimmun ELISA showed 96.8% and 81.3% positive and negative agreement, respectively, indicating that confirmatory testing of positive Euroimmun results on DBS extracts is necessary to achieve clinical accuracy. Our findings suggest that any SARS-CoV-2 antibody assay that requires pre-dilution of serum is amenable to DBS as an alternate specimen type that is relatively low cost, self-collectable, stable, can be shipped by standard mail and could be used to establish the seroprevalence of large populations.