Long-term measurements of aerosol optical depths (AODs) at 440 nm and Aangstrom exponents (AE) between 440 and 870 nm made for CARSNET were compiled into a climatology of aerosol optical properties ...for China. Quality-assured monthly mean AODs are presented for 50 sites representing remote, rural, and urban areas. AODs were 0.14, 0.34, 0.42, 0.54, and 0.74 at remote stations, rural/desert regions, the Loess Plateau, central and eastern China, and urban sites, respectively, and the corresponding AE values were 0.97, 0.55, 0.82, 1.19, and 1.05. AODs increased from north to south, with low values (< 0.20) over the Tibetan Plateau and northwestern China and high AODs (> 0.60) in central and eastern China where industrial emissions and anthropogenic activities were likely sources. AODs were 0.20-0.40 in semi-arid and arid regions and some background areas in northern and northeastern China. AEs were > 1.20 over the southern reaches of the Yangtze River and at clean sites in northeastern China. In the northwestern deserts and industrial parts of northeast China, AEs were lower (< 0.80) compared with central and eastern regions. Dust events in spring, hygroscopic particle growth during summer, and biomass burning contribute the high AODs, especially in northern and eastern China. The AODs show decreasing trends from 2006 to 2009 but increased ~ 0.03 per year from 2009 to 2013.
ABSTRACT
High time resolution and accuracy are of critical importance in the studies of timing analysis and time delay localization of gamma-ray bursts (GRBs), soft gamma-ray repeaters (SGRs) and ...pulsars. The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) consisting of two micro-satellites, GECAM-A and GECAM-B, launched on 2020 December 10, is aimed at monitoring and locating X-ray and GRBs all over the sky. To achieve its scientific goals, GECAM is designed to have the highest time resolution (0.1 $\mu {\rm s}$) among all GRB detectors ever flown. Here, we make a comprehensive time calibration campaign including both on-ground and on-orbit tests to derive not only the relative time accuracy of GECAM satellites and detectors, but also the absolute time accuracy of GECAM-B. Using the on-ground calibration with a $\rm ^{22}Na$ radioactive source, we find that the relative time accuracy between GECAM-A and GECAM-B is about 0.15 $\mu {\rm s}$ (1σ). To measure the relative time accuracy between all detectors of a single GECAM satellite, cosmic-ray events detected on orbit are utilized since they could produce many secondary particles simultaneously record by multiple detectors. We find that the relative time accuracy among all detectors onboard GECAM-B is about 0.12 $\mu {\rm s}$ (1σ). Finally, we use the novel Li-CCF method to perform the absolute time calibration with Crab pulsar and SGR J1935+2154, both of which were jointly observed by GECAM-B and Fermi/GBM, and obtain that the time difference between GECAM-B and Fermi/GBM is 3.06 ± 6.04 $\mu {\rm s}$ (1σ).
Background
The aim of this study was to investigate the prevalence of epidemiologic and physician‐diagnosed pollen‐induced AR (PiAR) in the grasslands of northern China and to study the impact of the ...intensity and time of pollen exposure on PiAR prevalence.
Methods
A multistage, clustered and proportionately stratified random sampling with a field interviewer‐administered survey study was performed together with skin prick tests (SPT) and measurements of the daily pollen count.
Results
A total of 6043 subjects completed the study, with a proportion of 32.4% epidemiologic AR and 18.5% PiAR. The prevalence was higher in males than females (19.6% vs 17.4%, P = .024), but no difference between the two major residential and ethnic groups (Han and Mongolian) was observed. Subjects from urban areas showed higher prevalence of PiAR than rural areas (23.1% vs 14.0%, P < .001). Most PiAR patients were sensitized to two or more pollens (79.4%) with artemisia, chenopodium, and humulus scandens being the most common pollen types, which were similarly found as the top three sensitizing pollen allergens by SPT. There were significant regional differences in the prevalence of epidemiologic AR (from 18.6% to 52.9%) and PiAR (from 10.5% to 31.4%) among the six areas investigated. PiAR symptoms were positively associated with pollen counts, temperature, and precipitation (P < .05), but negatively with wind speed and pressure P < .05).
Conclusion
Pollen‐induced AR (PiAR) prevalence in the investigated region is extremely high due to high seasonal pollen exposure, which was influenced by local environmental and climate conditions.
Our understanding of when and how humans adapted to living on the Tibetan Plateau at altitudes above 2000 to 3000 meters has been constrained by a paucity of archaeological data. Here we report data ...sets from the northeastern Tibetan Plateau indicating that the first villages were established only by 5200 calendar years before the present (cal yr B.P.). Using these data, we tested the hypothesis that a novel agropastoral economy facilitated year-round living at higher altitudes since 3600 cal yr B.P. This successful subsistence strategy facilitated the adaptation of farmers-herders to the challenges of global temperature decline during the late Holocene.
Here, in an analysis of a 2.92 fb–1 data sample taken at 3.773 GeV with the BESIII detector operated at the BEPCII collider, we measure the absolute decay branching fractions to be B(D0 → K–e+νe) = ...(3.505 ± 0.014 ± 0.033)% and B(D0 → π–e+νe) = (0.295 ± 0.004 ± 0.003)%. From a study of the differential decay rates we obtain the products of hadronic form factor and the magnitude of the CKM matrix element $f$ $^{K}_{+}$(0)|Vcs| = 0.7172 ± 0.0025 ± 0.0035 and $f$ $^{π}_{+}$(0)|Vcd| = 0.1435 ± 0.0018 ± 0.0009.
The cross section of the process e+e−→K+K− is measured at a number of center-of-mass energies s from 2.00 to 3.08 GeV with the BESIII detector at the Beijing Electron Positron Collider (BEPCII). The ...results provide the best precision achieved so far. A resonant structure around 2.2 GeV is observed in the cross section line shape. A Breit-Wigner fit yields a mass of M=2239.2±7.1±11.3 MeV/c2 and a width of Γ=139.8±12.3±20.6 MeV, where the first uncertainties are statistical and the second ones are systematic. In addition, the timelike electromagnetic form factor of the kaon is determined at the individual center-of-mass energy points.
The cross section for the process e^{+}e^{-}→π^{+}π^{-}J/ψ is measured precisely at center-of-mass energies from 3.77 to 4.60 GeV using 9 fb^{-1} of data collected with the BESIII detector operating ...at the BEPCII storage ring. Two resonant structures are observed in a fit to the cross section. The first resonance has a mass of (4222.0±3.1±1.4) MeV/c^{2} and a width of (44.1±4.3±2.0) MeV, while the second one has a mass of (4320.0±10.4±7.0) MeV/c^{2} and a width of (101.4_{-19.7}^{+25.3}±10.2) MeV, where the first errors are statistical and second ones are systematic. The first resonance agrees with the Y(4260) resonance reported by previous experiments. The precision of its resonant parameters is improved significantly. The second resonance is observed in e^{+}e^{-}→π^{+}π^{-}J/ψ for the first time. The statistical significance of this resonance is estimated to be larger than 7.6σ. The mass and width of the second resonance agree with the Y(4360) resonance reported by the BABAR and Belle experiments within errors. Finally, the Y(4008) resonance previously observed by the Belle experiment is not confirmed in the description of the BESIII data.