The Evolution mechanical dilator sheath is a new lead extraction tool that uses a rotational mechanism and a bladed tip to overcome fibrosis.
The purpose of this study was to report our initial ...experience with the Evolution system.
Between March 2008 (our first use of Evolution) and September 2009, the Evolution sheath was used for extraction of pacemaker or implantable cardioverter-defibrillator (ICD) leads in 29 patients (41 leads). Success and complications were defined according to the Heart Rhythm Society expert consensus document on lead extraction.
Indications for extraction were infection in 20 patients and lead malfunction in 9 patients. Median implantation time was 65 months (range 12-409 months). Of the 41 leads, 18 (44%) were atrial and 23 (56%) were ventricular. ICD leads were extracted from 14 (48%) patients and pacemaker leads from 15 (52%) patients. Evolution was used as first choice in 12 patients (16 39% leads), with 100% clinical success. Complete procedural success was achieved in 11 patients; in 1 patient, only the distal electrode was retained. The system was used for "rescue" of 25 (61%) leads in 17 patients. Success with Evolution alone was achieved in 13 (77%) patients (Shortie Evolution sheath used in 2), for complete procedural success of 77%. However, in 4 (24%) patients, Evolution was useful but not sufficient for complete procedural success (femoral workstation required in 2, reuse of laser in 2). Overall, the Evolution system was successful in 25 (86%) patients (33 leads). Overall clinical success was 100%. No complications occurred.
Preliminary data suggest that the Evolution mechanical dilator sheath is a new useful tool among the instruments available for lead extraction.
Chronic cough management necessitates a clear integrated care pathway approach. Primary care physicians initially encounter the majority of chronic cough patients, yet their role in proper management ...can prove challenging due to limited access to advanced diagnostic testing. A multidisciplinary approach involving otolaryngologists and chest physicians, allergists, and gastroenterologists, among others, is central to the optimal diagnosis and treatment of conditions which underly or worsen cough. These include infectious and inflammatory, upper and lower airway pathologies, or gastro-esophageal reflux. Despite the wide armamentarium of ancillary testing conducted in cough multidisciplinary care, such management can improve cough but seldom resolves it completely. This can be due partly to the limited data on the role of tests (eg, spirometry, exhaled nitric oxide), as well as classical pharmacotherapy conducted in multidisciplinary specialties for chronic cough. Other important factors include presence of multiple concomitant cough trigger mechanisms and the central neuronal complexity of chronic cough. Subsequent management conducted by cough specialists aims at control of cough refractory to prior interventions and includes cough-specific behavioral counseling and pharmacotherapy with neuromodulators, among others. Preliminary data on the role of neuromodulators in a proof-of-concept manner are encouraging but lack strong evidence on efficacy and safety.
The World Allergy Organization (WAO)/Allergic Rhinitis and its Impact on Asthma (ARIA) Joint Committee on Chronic Cough reviewed the recent literature on management of chronic cough in primary, multidisciplinary, and cough-specialty care. Knowledge gaps in diagnostic testing, classical and neuromodulator pharmacotherapy, in addition to behavioral therapy of chronic cough were also analyzed.
This third part of the WAO/ARIA consensus on chronic cough suggests a management algorithm of chronic cough in an integrated care pathway approach. Insights into the inherent limitations of multidisciplinary cough diagnostic testing, efficacy and safety of currently available antitussive pharmacotherapy, or the recently recognized behavioral therapy, can significantly improve the standards of care in patients with chronic cough.
Adriamycin is a chemotherapeutic agent that can cause severe cardiotoxicity, which potentially carries a poorer long-term prognosis than other forms of cardiomyopathy. Cardiac resynchronization ...therapy (CRT) has been shown to improve quality of life, exercise capacity, left ventricular ejection fraction, and survival in selected patients with heart failure. It is unclear if patients with Adriamycin-induced cardiomyopathy (AIC) respond to CRT. We reviewed clinical and echocardiographic data on 18 consecutive patients with AIC who underwent implantation of a CRT device at the Cleveland Clinic from February 2000 to April 2007. Changes in clinical and echocardiographic parameters were compared to 189 consecutive patients with other forms of nonischemic cardiomyopathy (NIC) using similar end points. Patients with AIC demonstrated significant improvements in ejection fraction, left ventricular end-diastolic and end-systolic diameters, mitral regurgitation, and New York Heart Association functional class with CRT. These changes were similar to patients in the NIC cohort. In conclusion, patients with AIC may derive a significant echocardiographic and symptomatic benefit from CRT, which is similar to that seen in other forms of NIC.
Objective Recent guidelines classify variable decelerations without detail as to degree of depth. We hypothesized that variable deceleration severity is highly correlated with fetal base deficit ...accumulation. Study Design Seven near-term fetal sheep underwent a series of graded umbilical cord occlusions resulting in mild (30 bpm decrease), moderate (60 bpm decrease), or severe (decrease of 90 bpm to baseline <70 bpm) variable decelerations at 2.5 minute intervals. Results Mild, moderate, and severe variable decelerations increased fetal base deficit (0.21 ± 0.03, 0.27 ± 0.03, and 0.54 ± 0.09 mEq/L per minute) in direct proportion to severity. During recovery, fetal base deficit cleared at 0.12 mEq/L per minute. Conclusion In this model, ovine fetuses can tolerate repetitive mild and moderate variable decelerations with minimal change in base deficit and lactate. In contrast, repetitive severe variable decelerations may result in significant base deficit increases, dependent on frequency. Modified guideline differentiation of mild/moderate vs severe variable decelerations may aid in the interpretation of fetal heart rate tracings and optimization of clinical management paradigms.
Background Due to limitations of technology, clinicians are typically unable to determine if human fetuses are normoxic or moderately, chronically hypoxic. Risk factors for chronic hypoxia include ...fetal growth restriction, which is associated with an increased incidence of oligohydramnios and thus a risk for umbilical cord occlusion (UCO) and variable fetal heart rate (FHR) decelerations. At delivery, fetal growth restriction infants (<3rd percentile) have nearly twice the incidence of low Apgar scores and umbilical pH <7.0. Despite the risks of oligohydramnios and intermittent UCO, there is little understanding of the acid/base responses rates of chronically hypoxic fetuses to variable FHR decelerations as might occur during human labor. Objective We sought to compare the increase in base deficit (BD) among chronically hypoxic as compared to normoxic ovine fetuses in response to simulated mild, moderate, and severe variable FHR decelerations. Study Design Near-term ovine fetuses were chronically prepared with brachial artery catheters and an inflatable umbilical cuff occluder. Following a recovery period, normoxic (n = 9) and spontaneously hypoxic (n = 5) fetuses were identified (arterial O2 saturation ≤55%). Both animal groups underwent graded, 1-minute occlusions every 2.5 minutes with 1 hour of mild (∼30 beats/min bpm decrease from baseline), 1 hour of moderate (∼60 bpm decrease from baseline), and up to 2 hours of severe (∼90 bpm decrease from baseline) variable FHR decelerations until fetal arterial pH reached 7.00, when occlusions were stopped. Results Repetitive UCO resulted in development of acidosis (pH <7.0) in both groups. Hypoxic and normoxic fetuses demonstrated similar BD increases in response to both mild (0.39, interquartile range IQR 0.28-0.45 vs 0.26, IQR 0.01-0.30 mEq/L/10 min, P = .25) and severe (1.97, IQR 1.50-2.43 vs 1.51, IQR 0.97-2.45 mEq/L/10 min, P = .63) variable decelerations. However, moderate variable decelerations increased BD in hypoxic fetuses at 2.5 times the rate of normoxic fetuses (0.97, IQR 0.52-1.72 vs 0.39, IQR 0.23-0.47 mEq/L/10 min, P = .03). During the recovery period, hypoxic fetuses cleared BD slower than normoxic fetuses (0.08 ± 0.02 vs 0.12 ± 0.03 mEq/L/min, P = .02). Conclusion In comparison to normoxic fetuses, hypoxic fetuses can more rapidly progress to significant metabolic acidosis in response to moderate FHR variable decelerations, and more slowly recover with in utero resuscitation, likely a consequence of impaired placental function and fetal physiologic responses.
Peanuts and tree nuts are common food allergens and are the leading cause of fatalities from food-induced anaphylaxis. Dietary avoidance is the primary management of these allergies and requires the ...ability to identify peanuts or tree nuts.
To investigate the ability of adults and children to visually identify peanuts and tree nuts.
A nut display was assembled that held peanuts and 9 tree nuts in a total of 19 different forms. Persons 6 years or older completed a worksheet to name the items.
One-thousand one-hundred five subjects completed the study. The mean number of peanuts and tree nuts identified by all subjects was 8.4 (44.2%) out of a possible 19. The mean for children ages 6 to 18 was 4.6 (24.2%), compared with 11.1 (58.4%) for adults older than 18 (P < .001). The most commonly identified items were peanut in the shell and without the shell. The least identified was hazelnut (filbert) in the shell and without the shell. No difference was seen in the performance of peanut- or tree nut-allergic subjects compared with nonallergic subjects. Fifty percent of subjects with a peanut or tree nut allergy correctly identified all forms of peanuts or tree nuts to which they are allergic. Parents of peanut- or tree nut-allergic children did no better than parents of children without such allergy.
Overall, both children and adults are unreliable at visually identifying most nuts. Treatment of nut allergies with dietary avoidance should include education for both adults and children on identification of peanuts and tree nuts.
Objectives This study sought to compare outcomes in patients with biventricular device infections who undergo successful treatment including extraction and reimplantation to patients with ...biventricular devices never known to become infected. Background Infection of a cardiac implantable electronic device (CIED) is associated with substantial morbidity and mortality. Survival in patients with cardiac resynchronization therapy (CRT) device infections undergoing full system extraction is unknown. Methods We extracted data on all patients undergoing extraction of a biventricular pacing device for an infectious indication at the Cleveland Clinic between February 16, 2000, and June 30, 2011. Survival of patients who presented with a CRT device infection, extraction, and successful reimplantation was compared to that of a large cohort of consecutive patients undergoing initial CRT implantation without a known history of subsequent device-related infection. In addition, long-term outcomes were compared between patients who were extracted and deemed to be cured with and without successful biventricular device reimplantation. Results In all, 151 patients underwent biventricular device extraction for infection, of whom 81 were successfully reimplanted. The noninfected cohort consisted of 879 patients. In a multivariate Cox regression model controlling for sex, a history of ischemic cardiomyopathy, creatinine, hemoglobin, beta-blocker use, angiotensin-converting enzyme inhibitor use, and diuretic use, no significant association between subsequent infection with reimplantation and all-cause mortality was noted (p = 0.21). There was a trend toward worse outcomes for patients extracted, deemed cured, and not reimplanted compared to patients with successful CRT reimplantation. Conclusions Patients with a biventricular device infection who are successfully extracted, treated with antibiotics, and reimplanted with a biventricular device have outcomes similar to those of patients with biventricular devices not known to have become infected.
There are limited published data regarding the percutaneous extraction of device leads jailed by a venous stent.
In this study we assessed the feasibility and safety of percutaneous extraction of ...stented device leads.
We reviewed our experience percutaneously extracting 7 chronically implanted device leads jailed to the wall of the left innominate and/or subclavian veins by a previously placed stent.
All leads were successfully extracted by using a percutaneous approach. Both pacing leads and defibrillator leads were extracted. The oldest pacing lead extracted was 14 years old. The oldest defibrillator lead extracted was 6 years old. Three of the leads were extracted with simple manual traction alone. The 4 remaining leads required a more complex, femoral extraction approach for successful removal.
In our experience extracting 7 stented device leads, complete percutaneous removal was feasible 100% of the time using a combination of simple manual traction and a femoral approach. No major complications were associated with the extraction procedures.
Abstract Objectives The study sought to assess the impact of previously abandoned leads on the clinical management of cardiac device infections, notably transvenous lead extraction and subsequent ...clinical course. Background The population of patients with cardiac implantable electronic devices continues to grow with a disproportionate increase in device infections, which are invariably life threatening. A potentially complicating issue is the widely practiced strategy of device lead abandonment at the time of system revision, change, or upgrade, which is affecting an increasing number of patients. Methods The study assessed the impact of previously abandoned leads in a prospectively maintained registry of consecutive patients undergoing percutaneous extraction of infected cardiac devices at the Cleveland Clinic between August 1996 and September 2012. The primary clinical endpoint was complete procedural and clinical success defined as the successful removal of the device and all lead material from the vascular space, in the absence of a major complication. Results Of 1,386 patients with infected cardiac devices, 323 (23.3%) had previously abandoned leads. Failure to achieve the primary endpoint occurred more frequently in patients with abandoned leads (13.0% vs. 3.7%; p < 0.0001). This was primarily due to retention of lead material (11.5% vs. 2.9%; p < 0.0001), which was associated with poor clinical outcomes including higher rates of 1-month mortality (7.4% vs. 3.5% in those without lead remnants). Lead extraction procedures in patients with previously abandoned leads were longer (p < 0.0001), with longer fluoroscopy times (p < 0.0001), and more likely to require specialized extraction tools (94.4% vs. 81.8%; p < 0.0001) or adjunctive rescue femoral workstations (14.9% vs. 2.9%; p < 0.0001). Procedural complications occurred more frequently in patients with previously abandoned leads (11.5% vs. 5.6%; p = 0.0003), which was true for both major (3.7% vs. 1.4%; p = 0.009) and minor complications (7.7% vs. 4.4%; p = 0.02). Conclusions Previously abandoned leads complicate the management of cardiac device infections, leading to worse clinical outcomes.
In total hip arthroplasty (THA), component position is critical to avoid instability and improve longevity. Appropriate combined femoral and acetabular component anteversion is important for improved ...THA stability and increased impingement-free range of motion. In direct anterior THA (DA-THA), concern has been expressed regarding the accuracy of femoral component positioning. This study seeks to quantify acetabular, femoral, and combined component orientation relative to the accepted “safe zones” in patients who have undergone DA-THA.
Twenty-nine patients who had THA performed via direct anterior approach had postoperative computerized tomography scans done to assess femoral anteversion. Stem rotational alignment was measured relative to the transepicondylar axis (TEA) and the posterior condylar axis (PCA) of the femur at the knee. Acetabular abduction and version were recorded on anteroposterior pelvis radiographs.
The mean stem anteversion was 17.5° (standard deviation = 10.8°) from the TEA and 21.7° (standard deviation = 11.3°) from the PCA. Ten of 30 cups were appropriately anteverted; however, all the cups had appropriate abduction. Combined version when using the TEA resulted in 79% (23/29) of patients within the “safe zone” of 25°-50°. Pearson correlation coefficients were high for both stem anteversion from the TEA (R = 0.96) and PCA (R = 0.98); however, interobserver reliability for combined component anteversion was greater for the TEA (kappa, 0.83 vs 0.65).
Combined anteversion within the “safe zone” was achieved 79% of the time with DA-THA. Interestingly, most of the “excessive” combined anteversion appears to be related to increased anteversion of the acetabular component with only 10 patients within the acetabular cup “safe zone” of 5°-25°.