Abstract Objective To evaluate the open laminate technique using glass ionomer cements (GIC) in association with a low shrink composite for restoring root filled premolars. Methods Extensive MOD ...cavities plus endodontic access and root filling were performed in intact extracted maxillary premolars. Three restoration types were evaluated: (1) resin composite alone; (2) resin-modified GIC (RM-GIC) open laminate plus resin composite; (3) conventional GIC open laminate plus resin composite ( n = 8 for all groups and tests). Three tests were conducted to assess restorations: (A) inward cusp deflection during light curing, using DCDTs; (B) fracture strength using a ramped oblique load at 45° to the long axis in a servohydraulic testing machine in comparison with intact and unrestored teeth; (C) proximal marginal leakage using methylene blue dye and the effect of thermocycling. Data were analysed using 1-way ANOVA for cuspal deflection and fracture strength and Fisher's exact test for leakage. Results Laminate restorations resulted in significantly less cuspal deflection compared with resin composite (4.2 ± 1.2 μm for RM-GIC and 5.1 ± 2.3 μm for conventional GIC vs. 12.2 ± 2.6 μm for composite, P < 0.001). Fracture strength was not significantly different among all groups. Failure with all restorations was predominantly adhesive at the tooth-restoration interface. The two laminate groups showed significantly better marginal seal than composite alone, but sealing ability of conventional GIC deteriorated after thermocycling. Conclusions Laminate restoration of root filled teeth had beneficial effects in terms of reducing cuspal deflection and marginal seal, with acceptable fracture strength.
Abstract Objectives To investigate the response of extracted intact teeth to thermal stimulation in terms of fluid movement, in relation to temperature change within tooth structure. Methods Dentinal ...fluid movement was measured in response to thermal stimuli applied to enamel. Freshly extracted teeth with intact crowns were investigated for the effects of thermal stimulation; namely, hot water (80 °C), iced water (2 °C) and carbon dioxide dry ice (−72 °C) for 5 s application. Two capillary-based methods were used to measure fluid flow. To measure temperature changes at the dentino-enamel junction (DEJ) and pulpal wall in response to the same stimuli, fine J type thermocouples were used. Results Thermal stimuli caused fluid movement, which occurred before the temperature changed at the pulp wall. Sealing the dentinal tubules resulted in a delayed response time. In general, fluid movement occurred coincident with the temperature change detected at the DEJ. However, many teeth showed a “bidirectional” response to thermal stimulation. The initial fluid movement in the bidirectional response was detected before the earliest temperature change observed at the DEJ, and was in the opposite direction to the main fluid movement. Conclusion Our results imply that thermal contraction and expansion of dentinal fluid may not be the complete explanation for dentinal fluid movement in intact teeth. Enamel may serve not only as a temperature transfer medium but may also expand or contract when subjected to thermal stimulation.
An effect of dentinal tubule orientation on mechanical properties of dentin has been difficult to demonstrate. We have tested the hypothesis that ultimate tensile strength (UTS) of dentin is affected ...by tubule (and hence collagen fibril) orientation. The UTS of human root dentin was investigated by direct tensile and diametral testing of specimens of known orientation prepared from extracted teeth. Dumbbell-shaped samples were machined for direct tensile testing (load parallel or perpendicular to tubule direction) and cylinders for diametral testing (load at 0°, 45°, 67.5°, and 90°). Fractured surfaces were examined by SEM. UTS was lowest when the tensile force was parallel to tubule orientation, and greatest at 90° to tubule orientation (fracture parallel to tubule direction). SEM views of fractured surfaces suggested that microstructure contributes to fracture patterns. At least for properties involving disruption of the collagen matrix, root dentin shows a definite anisotropy.
Two 3-dimensional models, one of a lower second premolar and one of a lower central incisor were used to investigate effects of load on the location and magnitude of cervical strains.
Point loads of ...100
N were applied to the model premolar (at the cusp tip, parallel and 45° to the long axis of the tooth) and incisor (at the mid-buccal point on incisal edge, parallel and 45° to the long axis of the tooth). Outputs were presented in the form of tensile-strain contours and vector plots.
Strains were concentrated near the cementoenamel junction (CEJ) regardless of load direction, and oblique loading showed higher tensile strains, opposite to the point of loading, than vertical loading for both models. For the premolar model, regardless of loading direction, strains were concentrated at the mid- buccal CEJ. In contrast, under vertical loading on the incisor model, tensile strains were concentrated at the line-angle of CEJ. From oblique loads, vector plots of both models showed tensile vectors in vertical directions while vertical loads showed tensile vectors in horizontal directions.
Mechanisms of non-carious cervical lesions (NCCLs) may in part be due the changing orientation of tensile strains as well as their magnitude. Stress concentration at the CEJ related well to the common location of clinical NCCLs. The crown-root morphology may have an influence on the initial location of non-carious cervical lesions.
Nickel-titanium engine-driven rotary instruments are used increasingly in endodontic practice. One frequently mentioned problem is fracture of an instrument in the root canal. Very few studies have ...been conducted on torsional characteristics of these instruments, and none has been done under dynamic conditions. The purposes of this study were to measure the torque generated and the apical force applied during instrumentation with a commercial engine-driven nickel-titanium file system, and to relate torque generated during simulated clinical use to torsional failure of the instruments. Ten extracted human teeth (five with small-sized and five with medium-sized straight root canals) were instrumented with Quantec Series 2000 files, and the torque and apical force generated were measured. The applied apical force was generally low, not exceeding 150 g in either small or medium canals. The torque depended on the tip size and taper of each instrument, and on canal size. Instruments with 0.05 and 0.06 taper generated the highest torque, which was greater in small than in medium canals. The torque at failure was significantly (p < 0.001) higher than torque during instrumentation, but with considerable variation in the extent of the difference.
The aim of this study was to determine the bonding effectiveness of four self-etching primer adhesives after various tooth preparation protocols. Enamel/dentin specimens were prepared from 84 ...permanent molars, divided into three enamel preparation groups (silicon carbide paper SiC1; erbium, chromium:yttri-um, scandium, gallium, garnet Er,Cr:YSGG laser EL and diamond bur DB) and five dentin preparation groups (SiC, EL, DB, steelSB, and ceramic burs CBs). In each group,specimens were equally divided into four sub-groups and were bonded using Clearfil SEBond (CSE, Kuraray), Xeno IV (XE, Dentsply),Tokuyama Bond Force (TK, Tokuyama) and Filtek Silorane System Adhesive (FS, 3MESPE), as well as a hybrid resin composite(Clearfil Majesty Esthetic, Kuraray) for CSE,XE, and TK, and Filtek Posterior Restorative(3M ESPE) for FS). After 24 hours of water storage at 370C, microshear bond strength(iSBS) testing was carried out. Data were analyzed using analysis of variance (ANOVA)-Tukey test at a=0.05 and bond failure modes assessed. Representative debonded specimens were prepared and examined under the scanning electron microscope (SEM). All adhesives exhibited no significant differences in 1SBS on enamel and dentin under the clinical cavity preparation protocols, except for TK on den-tin. SEM revealed areas of altered subsurface enamel/dentin following EL ablation.
This study investigated cuspal deformation in teeth restored with different types of adhesive materials with and without a base.
Mesio-occluso-distal slot cavities of moderately large dimension were ...prepared on extracted maxillary premolars (n=24). Teeth were assigned to one of four groups and restored with either a sonic-activated bulk-fill resin composite (RC) (SonicFill), or a conventional nanohybrid RC (Herculite Ultra). The base materials used were a flowable nanofilled RC (Premise Flowable) and a high-viscosity resin-modified glass-ionomer cement (RMGIC) (Riva Light-Cure HV). Cuspal deflection was measured with two direct current differential transformers, each contacting a buccal and palatal cusp. Cuspal movements were recorded during and after restoration placement. Data for the buccal and palatal cusp deflections were combined to give the net cuspal deflection.
Data varied widely. All teeth experienced net inward cuspal movement. No statistically significant differences in cuspal deflection were found among the four test groups.
The use of a flowable RC or an RMGIC in closed-laminate restorations produced the same degree of cuspal movement as restorations filled with only a conventional nanohybrid or bulk-fill RC.
The purpose of the study was to determine whether rotary nickel-titanium (NiTi) canal preparation strengthens roots, and whether the fracture pattern can be predicted by finite element analysis (FEA) ...models. From a fracture mechanics viewpoint, structural defects, cracks or canal irregularities are likely to play a major role in fracture susceptibility of the roots, because stresses can be exponentially amplified at these sites. By incorporating defects into a smooth round canal using rotary NiTi, theoretically the roots could be strengthened. 25 teeth were prepared using hand files and another 25 using rotary NiTi. After obturation, all teeth were subject to loading until fracture; load and patterns were recorded. Four FEA models were created from fractured roots. No significant difference of fracture load between the two techniques was found. Mesio-distal fracture occurred more often in the rotary NiTi group. Stress patterns in three of the four FEA models correlated well with the observed fracture patterns.
The relationship between gap formation and outward fluid flow and procedures to minimize both phenomena were investigated in extracted human premolars restored in vitro with MOD composite ...restorations. We hypothesized that either glass-ionomer cement (GIC) liners or low-shrinkage composite could reduce fluid flow related to gap formation. Two groups restored with bonding agents with either high- or low-shrinkage resin composites, and 2 groups restored by either conventional or light-cured GIC liner plus resin composite were compared (8 teeth/group). Fluid flow was measured with an automated apparatus. Baseline fluid flow was low and unchanged after bonding, but increased sharply (though transiently) after teeth were lined with GIC. Outward flow was significantly greater with conventional than with light-cured GIC. Inward fluid flow occurred during light-curing, followed by extensive, prolonged outward flow after curing. Low-shrinkage composite or GIC liners reduced gap formation and limited outward fluid flow. GIC liners promoted outward fluid flow during their setting reactions. Abbreviations: GIC, glass-ionomer cement; CEJ, cemento-enamel junction; MOD, mesio-occluso-distal; SEM, scanning electron microscopy.
Aim To evaluate the effect of repeated cleaning procedures on fracture properties and corrosion of nickel‐titanium (NiTi) files.
Methodology New NiTi instruments were subjected to 2, 5 and 10 ...cleaning cycles with the use of either diluted bleach (1% NaOCl) or Milton's solution (1% NaOCl plus 19% NaCl) as disinfectant. Each cleaning cycle consisted of scrubbing, rinsing and immersing in NaOCl for 10 min followed by 5 min of ultrasonication. Files were then tested for torsional failure and flexural fatigue, and observed for evidence of corrosion using scanning electron microscope (SEM). Four brands of NiTi files were immersed in either Milton's solution or diluted bleach overnight and evaluated for corrosion.
Results Up to 10 cleaning cycles did not significantly reduce the torque at fracture or number of revolutions to flexural fatigue (P > 0.05, two‐way anova), although decreasing values were noted with increasing number of cleaning cycles using Milton's solution. No corrosion was detected on the surface of these files. Files immersed in 1% NaOCl overnight displayed a variety of corrosion patterns. The extent of corrosion was variable amongst different brands of files and amongst files in each brand. Overall, Milton's solution was much more corrosive than diluted bleach. Corrosion of file handles was often extreme.
Conclusions Files can be cleaned up to 10 times without affecting fracture susceptibility or corrosion, but should not be immersed in NaOCl overnight. Milton's solution is much more corrosive than bleach with the same NaOCl concentration.